Utilization of superconducting magnetic energy storage and doubly fed induction generator for enhancing stability of interconnected power system

被引:2
|
作者
Kumar, Abdul Waheed [1 ]
Mufti, Mairaj Ud Din [1 ]
Zargar, Mubashar Yaqoob [2 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Srinagar, Jammu & Kashmir, India
[2] Islamic Univ Sci & Technol, Dept Elect Engn, Awantipora, Jammu & Kashmir, India
关键词
doubly fed induction generator; dynamic stability; eigenvalue analysis; superconducting magnetic energy storage; virtual synchronous generator; LARGE-SCALE; WIND FARM;
D O I
10.1002/cta.3699
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the share of wind power keeps on increasing, the interaction between synchronous and wind generators pose a challenging issue on power system stability. In order to investigate the impact of wind penetration on stability of power system, appropriate modeling of wind energy conversion systems (WECSs) is necessary. Moreover, it is needed to comprehensively study the impact of wind penetration on power system oscillations. This paper presents a didactic approach for integrating a doubly fed induction generator (DFIG)-based wind farm from SimPower Systems library to a five-area 68-bus power system modeled in Simulink. Inter-area oscillations with and without wind power penetration are investigated for their characteristics. Renewable energy sources are connected to the grid via power electronics converters at the cost of a reduction in inertia. The concept of virtual synchronous generator (VSG) produces virtual inertia by exchanging active power with the power system. The impact of superconducting magnetic energy storage (SMES) and DFIG on enhancing damping performance of inter-area is investigated. The increase in damping ratios of inter-area oscillatory modes verifies the enhancement in small signal stability by connecting SMES and DFIG to the power system. The usage of SMES operating in VSG mode to improve the dynamic stability with highly erratic wind profile is also investigated. The developed MATLAB/SIMULINK-based DFIG model is simple to use and can be expanded to build efficient controllers. The fidelity of the DFIG model and VSG technology is verified in real time by Opal-RT (OP4510).
引用
收藏
页码:5251 / 5268
页数:18
相关论文
共 50 条
  • [31] Active and reactive power control of the doubly fed induction generator based on wind energy conversion system
    Kaloi, Ghulam Sarwar
    Wang, Jie
    Baloch, Mazhar Hussain
    ENERGY REPORTS, 2016, 2 : 194 - 200
  • [32] IMPROVED DIRECT POWER CONTROL OF A DOUBLY FED INDUCTION GENERATOR BASED WIND ENERGY CONVERSION SYSTEM
    Kadri, Ameni
    Marzougui, Hajer
    Omrani, Khaoula
    Bacha, Faouzi
    2018 5TH INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT), 2018, : 707 - 712
  • [33] Automatic generation control of an interconnected hydrothermal power system considering superconducting magnetic energy storage
    Abraham, Rajesh Joseph
    Das, D.
    Patra, Amit
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2007, 29 (08) : 571 - 579
  • [34] Smoothing control of wind power generator output by Superconducting Magnetic Energy Storage system
    Asao, Tomoki
    Takahashi, Rion
    Murata, Toshiaki
    Tamura, Junji
    Kubo, Masahiro
    Kuwayama, Akira
    Matsumoto, Takatoshi
    2007 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-4, 2007, : 1532 - +
  • [35] Backstepping control of a doubly fed induction generator integrated to wind power system
    El Azzaoui, Marouane
    Mahmoudi, Hassane
    Ed-dahmani, Chafik
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL AND INFORMATION TECHNOLOGIES (ICEIT), 2016, : 306 - 311
  • [36] System Modeling and Simulation of a Wind Power Generation with Doubly Fed Induction Generator
    Shi, Yun
    Liu, Ai
    Lin, Chengwu
    PROCEEDINGS OF THE6TH INTERNATIONAL CONFERENCE ON MECHATRONICS, MATERIALS, BIOTECHNOLOGY AND ENVIRONMENT (ICMMBE 2016), 2016, 83 : 148 - 152
  • [37] Field Oriented Control of Doubly Fed Induction Generator in Wind Power System
    Charles, Rahul C. M.
    Vinod, V.
    Jacob, Anju
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (ICCIC), 2015, : 493 - 497
  • [38] Power System Oscillation Damping Capability of Doubly Fed Induction Generator (DFIG)
    Gurung, Niroj
    Kamalasadan, Sukumar
    2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [39] Review of Transient Power Angle Stability of Doubly-fed Induction Generator With Virtual Synchronous Generator Technology Integration System
    Cheng X.
    Liu H.
    Tian Y.
    Zhao F.
    Sun D.
    Song P.
    Zhang R.
    Cheng, Xuekun (chengxk027@126.com), 1600, Power System Technology Press (45): : 518 - 525
  • [40] Two-layer control scheme for a Supercapacitor Energy Storage System coupled to a Doubly Fed Induction Generator
    Syed, Irtaza M.
    Venkatesh, Bala
    Wu, Bin
    Nassif, Alexandre B.
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 86 : 76 - 83