Quantification of spinal bone marrow fat fraction using three-material decomposition technique on dual-energy CT: A phantom study

被引:1
作者
Li, Baojun [1 ,2 ]
Hua, Ning [1 ]
Li, Janelle [1 ]
Andreu-Arasa, V. Carlota [1 ]
LeBedis, Christina [1 ]
Anderson, Stephan W. [1 ]
机构
[1] Boston Univ, Dept Radiol, Sch Med, Boston, MA USA
[2] Boston Univ, Dept Radiol, Sch Med, 820 Harrison Ave,FGH BLDG,3rd Floor, Boston, MA 02118 USA
关键词
bone edema; CT; dual-energy; fat fraction; three-material decomposition; MINERAL DENSITY; IN-VIVO; MRI; FRACTURES; ACCURACY; LESIONS; EDEMA;
D O I
10.1002/mp.16442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTwo-material decomposition is insufficient to quantify the fat fraction of spinal bone marrow, which is comprised of a mixture of bone minerals, water, and yellow marrow (fat). PurposeTo develop an accurate three-material decomposition-based bone marrow fat fraction (FF3MD$F{F_{3MD}}$) quantification technique for dual-energy CT. MethodsBone marrow edema phantoms containing trabecular bone minerals, water, and fat were constructed using fat fractions and bone mineral density values matching those expected in healthy and edematous bone, and scanned on a commercial dual-energy CT. Fat quantified by FF3MD$F{F_{3MD}}$ were compared to MRI-based fat fraction (FFMRI$F{F_{MRI}}$) and conventional two-material-decomposition-based fat fraction (FF2MD$F{F_{2MD}}$) to evaluate its accuracy and dependency on various bone mineral densities. ResultsFF3MD$F{F_{3MD}}$ demonstrated an excellent correlation with FFMRI$F{F_{MRI}}\;$(r = 0.97, R-2 = 0.96) in the phantom, significantly more accurate than FF2MD when confounding bone minerals are present (50 mg/cm(3): r = 1.02, R-2 = 0.95 vs. r = 0.65, R-2 = 0.79 (p < 0.01); 100 mg/cm(3): r = 0.81, R-2 = 0.47 vs. r = 0.21, R-2 = 0.21 (p < 0.05)). ConclusionsFF3MD$F{F_{3MD}}$ accurately quantified bone marrow fat fraction, when compared with FFMRI$F{F_{MRI}}$, in the specially constructed bone marrow phantom.
引用
收藏
页码:4105 / 4111
页数:7
相关论文
共 50 条
[41]   Nondisplaced fractures on hip CT: added value of dual-energy CT virtual non-calcium imaging for detection of bone marrow edema using visual and quantitative analyses [J].
Jang, Seong Won ;
Chung, Bo Mi ;
Kim, Wan Tae ;
Gil, Jea Ryung .
ACTA RADIOLOGICA, 2019, 60 (11) :1465-1473
[42]   Marrow Adipose Tissue Quantification of the Lumbar Spine by Using Dual-Energy CT and Single-Voxel 1H MR Spectroscopy: A Feasibility Study [J].
Bredella, Miriam A. ;
Daley, Scott M. ;
Kalra, Mannudeep K. ;
Brown, J. Keenan ;
Miller, Karen K. ;
Torriani, Martin .
RADIOLOGY, 2015, 277 (01) :230-235
[43]   Contrast agent concentration optimization in CTA using low tube voltage and dual-energy CT in multiple vendors: a phantom study [J].
van Hamersvelt, Robbert W. ;
Eijsvoogel, Nienke G. ;
Mihl, Casper ;
de Jong, Pim A. ;
Schilham, Arnold M. R. ;
Buls, Nico ;
Das, Marco ;
Leiner, Tim ;
Willemink, Martin J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (08) :1265-1275
[44]   Water/cortical bone decomposition: A new approach in dual energy CT imaging for bone marrow oedema detection. A feasibility study [J].
Biondi, M. ;
Vanzi, E. ;
De Otto, G. ;
Buonamici, F. Banci ;
Belmonte, G. M. ;
Mazzoni, L. N. ;
Guasti, A. ;
Carbone, S. F. ;
Mazzei, M. A. ;
La Penna, A. ;
Foder, E. ;
Guerreri, D. ;
Maiolino, A. ;
Volterrani, L. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12) :1712-1716
[45]   Accuracy and Robustness of Bone Volume Fraction Assessment by Photon-Counting, Dual-Energy, and Quantitative CT using Micro-CT as Standard of Reference [J].
Wili, Patrik ;
Gascho, Dominic ;
Dudle, Alice ;
Marcus, Roy P. ;
Nanz, Daniel ;
Thali, Michael ;
Zysset, Philippe .
ANNALS OF BIOMEDICAL ENGINEERING, 2025,
[46]   Pseudoenhancement effects on iodine quantification from dual-energy spectral CT systems: A multi-vendor phantom study regarding renal lesion characterization [J].
Soesbe, Todd C. ;
Ananthakrishnan, Lakshmi ;
Lewis, Matthew A. ;
Duan, Xinhui ;
Nasr, Khaled ;
Xi, Yin ;
Abbara, Suhny ;
Leyendecker, John R. ;
Lenkinski, Robert E. .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 :125-133
[47]   Spectral computed tomography for quantitative decomposition of vulnerable plaques using a dual-energy technique: a Monte Carlo simulation study [J].
Jo, B. D. ;
Park, S. -J. ;
Kim, H. M. ;
Kim, D. H. ;
Kim, H. -J. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[48]   Dual-energy CT virtual non-calcium technique for detection of bone marrow edema in patients with vertebral fractures: A prospective feasibility study on a single-source volume CT scanner [J].
Diekhoffa, T. ;
Hermann, K. G. ;
Pumberger, M. ;
Hamm, B. ;
Putzier, M. ;
Fuchs, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 :59-65
[49]   Application of dual-energy CT to suppression of metal artefact caused by pedicle screw fixation in radiotherapy: a feasibility study using original phantom [J].
Wang, Tianyuan ;
Ishihara, Takeaki ;
Kono, Atsushi ;
Yoshida, Naoki ;
Akasaka, Hiroaki ;
Mukumoto, Naritoshi ;
Yada, Ryuichi ;
Ejima, Yasuo ;
Yoshida, Kenji ;
Miyawaki, Daisuke ;
Kakutani, Kenichiro ;
Nishida, Kotaro ;
Negi, Noriyuki ;
Minami, Toshiaki ;
Aoyama, Yuuichi ;
Takahashi, Satoru ;
Sasaki, Ryohei .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (15) :6226-6245
[50]   Visualization of joint and bone using dual-energy CT arthrography with contrast subtraction: in vitro feasibility study using porcine joints [J].
Chai, Jee Won ;
Choi, Jung-Ah ;
Choi, Ja-Young ;
Kim, Sujin ;
Hong, Sung Hwan ;
Kang, Heung Sik .
SKELETAL RADIOLOGY, 2014, 43 (05) :673-678