摘要
BackgroundTwo-material decomposition is insufficient to quantify the fat fraction of spinal bone marrow, which is comprised of a mixture of bone minerals, water, and yellow marrow (fat). PurposeTo develop an accurate three-material decomposition-based bone marrow fat fraction (FF3MD$F{F_{3MD}}$) quantification technique for dual-energy CT. MethodsBone marrow edema phantoms containing trabecular bone minerals, water, and fat were constructed using fat fractions and bone mineral density values matching those expected in healthy and edematous bone, and scanned on a commercial dual-energy CT. Fat quantified by FF3MD$F{F_{3MD}}$ were compared to MRI-based fat fraction (FFMRI$F{F_{MRI}}$) and conventional two-material-decomposition-based fat fraction (FF2MD$F{F_{2MD}}$) to evaluate its accuracy and dependency on various bone mineral densities. ResultsFF3MD$F{F_{3MD}}$ demonstrated an excellent correlation with FFMRI$F{F_{MRI}}\;$(r = 0.97, R-2 = 0.96) in the phantom, significantly more accurate than FF2MD when confounding bone minerals are present (50 mg/cm(3): r = 1.02, R-2 = 0.95 vs. r = 0.65, R-2 = 0.79 (p < 0.01); 100 mg/cm(3): r = 0.81, R-2 = 0.47 vs. r = 0.21, R-2 = 0.21 (p < 0.05)). ConclusionsFF3MD$F{F_{3MD}}$ accurately quantified bone marrow fat fraction, when compared with FFMRI$F{F_{MRI}}$, in the specially constructed bone marrow phantom.
引用
收藏
页码:4105 / 4111
页数:7
相关论文
共 50 条
[21]   Accuracy of Dual-Energy Computed Tomography Techniques for Fat Quantification in Comparison With Magnetic Resonance Proton Density Fat Fraction and Single-Energy Computed Tomography in an Anthropomorphic Phantom Environment [J].
Wu, Zi Jun ;
Hippe, Daniel S. ;
Zamora, David A. ;
Briller, Noah ;
Amin, Kathan A. ;
Kolokythas, Orpheus ;
Mileto, Achille .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (06) :877-887
[22]   Detection of bone marrow oedema in knee joints using a dual-energy CT virtual non-calcium technique [J].
Wang, M-Y ;
Zhang, X-Y ;
Xu, L. ;
Feng, Y. ;
Xu, Y-C ;
Qi, L. ;
Zou, Y-F .
CLINICAL RADIOLOGY, 2019, 74 (10) :815.e1-815.e7
[23]   Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study [J].
Kawai, Tatsuya ;
Takeuchi, Mitsuru ;
Hara, Masaki ;
Ohashi, Kazuya ;
Suzuki, Hirochika ;
Yamada, Kiyotaka ;
Sugimura, Yuya ;
Shibamoto, Yuta .
ACTA RADIOLOGICA, 2013, 54 (08) :954-960
[24]   Development of a novel algorithm for metal artifact reduction in digital tomosynthesis using projection-based dual-energy material decomposition for arthroplasty: A phantom study [J].
Gomi, Tsutomu ;
Sakai, Rina ;
Goto, Masami ;
Hara, Hidetake ;
Watanabe, Yusuke .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 53 :4-16
[25]   Multiple Myeloma and Dual-Energy CT: Diagnostic Accuracy of Virtual Noncalcium Technique for Detection of Bone Marrow Infiltration of the Spine and Pelvis [J].
Kosmala, Aleksander ;
Weng, Andreas Max ;
Heidemeier, Anke ;
Krauss, Bernhard ;
Knop, Stefan ;
Bley, Thorsten Alexander ;
Petritsch, Bernhard .
RADIOLOGY, 2018, 286 (01) :205-213
[26]   Bone Mineral Density (BMD) Assessment Using Dual-Energy CT with Different Base Material Pairs (BMPs) [J].
Piscone, Stefano ;
Saccone, Sara ;
Milillo, Paola ;
Schiraldi, Giorgia ;
Vinci, Roberta ;
Macarini, Luca ;
Stoppino, Luca Pio .
JOURNAL OF IMAGING, 2025, 11 (07)
[27]   Quantification of Liver Fat in the Presence of Iron and Iodine An Ex-Vivo Dual-Energy CT Study [J].
Fischer, Michael A. ;
Gnannt, Ralph ;
Raptis, Dimitri ;
Reiner, Caecilia S. ;
Clavien, Pierre-Alain ;
Schmidt, Bernhard ;
Leschka, Sebastian ;
Alkadhi, Hatem ;
Goetti, Robert .
INVESTIGATIVE RADIOLOGY, 2011, 46 (06) :351-358
[28]   Accuracy and precision of volumetric bone mineral density assessment using dual-source dual-energy versus quantitative CT: a phantom study [J].
Koch, Vitali ;
Hokamp, Nils Grosse ;
Albrecht, Moritz H. ;
Gruenewald, Leon D. ;
Yel, Ibrahim ;
Borggrefe, Jan ;
Wesarg, Stefan ;
Eichler, Katrin ;
Burck, Iris ;
Gruber-Rouh, Tatjana ;
Lenga, Lukas ;
Vogl, Thomas J. ;
Martin, Simon S. ;
Wichmann, Julian L. ;
Hammerstingl, Renate M. ;
Alizadeh, Leona S. ;
Mader, Christoph ;
Huizinga, Nicole A. ;
D'Angelo, Tommaso ;
Ascenti, Giorgio ;
Mazziotti, Silvio ;
Booz, Christian .
EUROPEAN RADIOLOGY EXPERIMENTAL, 2021, 5 (01)
[29]   Investigating new CT contrast agents: a phantom study exploring quantification and differentiation methods for high-Z elements using dual-energy CT [J].
Soesbe, Todd C. ;
Xi, Yin ;
Nasr, Khaled ;
Leyendecker, John R. ;
Lenkinski, Robert E. ;
Lewis, Matthew A. .
EUROPEAN RADIOLOGY, 2021, 31 (10) :8060-8067
[30]   Dose Reduction Does Not Affect Detection of Bone Marrow Lesions with Dual-energy CT Virtual Noncalcium Technique [J].
Pache, Gregor ;
Bulla, Stefan ;
Baumann, Tobias ;
Bayer, Joerg ;
Reising, Kilian ;
Strohm, Peter ;
Langer, Mathias ;
Blanke, Philipp .
ACADEMIC RADIOLOGY, 2012, 19 (12) :1539-1545