Quantification of spinal bone marrow fat fraction using three-material decomposition technique on dual-energy CT: A phantom study

被引:0
|
作者
Li, Baojun [1 ,2 ]
Hua, Ning [1 ]
Li, Janelle [1 ]
Andreu-Arasa, V. Carlota [1 ]
LeBedis, Christina [1 ]
Anderson, Stephan W. [1 ]
机构
[1] Boston Univ, Dept Radiol, Sch Med, Boston, MA USA
[2] Boston Univ, Dept Radiol, Sch Med, 820 Harrison Ave,FGH BLDG,3rd Floor, Boston, MA 02118 USA
关键词
bone edema; CT; dual-energy; fat fraction; three-material decomposition; MINERAL DENSITY; IN-VIVO; MRI; FRACTURES; ACCURACY; LESIONS; EDEMA;
D O I
10.1002/mp.16442
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundTwo-material decomposition is insufficient to quantify the fat fraction of spinal bone marrow, which is comprised of a mixture of bone minerals, water, and yellow marrow (fat). PurposeTo develop an accurate three-material decomposition-based bone marrow fat fraction (FF3MD$F{F_{3MD}}$) quantification technique for dual-energy CT. MethodsBone marrow edema phantoms containing trabecular bone minerals, water, and fat were constructed using fat fractions and bone mineral density values matching those expected in healthy and edematous bone, and scanned on a commercial dual-energy CT. Fat quantified by FF3MD$F{F_{3MD}}$ were compared to MRI-based fat fraction (FFMRI$F{F_{MRI}}$) and conventional two-material-decomposition-based fat fraction (FF2MD$F{F_{2MD}}$) to evaluate its accuracy and dependency on various bone mineral densities. ResultsFF3MD$F{F_{3MD}}$ demonstrated an excellent correlation with FFMRI$F{F_{MRI}}\;$(r = 0.97, R-2 = 0.96) in the phantom, significantly more accurate than FF2MD when confounding bone minerals are present (50 mg/cm(3): r = 1.02, R-2 = 0.95 vs. r = 0.65, R-2 = 0.79 (p < 0.01); 100 mg/cm(3): r = 0.81, R-2 = 0.47 vs. r = 0.21, R-2 = 0.21 (p < 0.05)). ConclusionsFF3MD$F{F_{3MD}}$ accurately quantified bone marrow fat fraction, when compared with FFMRI$F{F_{MRI}}$, in the specially constructed bone marrow phantom.
引用
收藏
页码:4105 / 4111
页数:7
相关论文
共 50 条
  • [1] Hepatic fat quantification in dual-layer computed tomography using a three-material decomposition algorithm
    Demondion, Emilie
    Ernst, Olivier
    Louvet, Alexandre
    Robert, Benjamin
    Kafri, Galit
    Langzam, Eran
    Vermersch, Mathilde
    EUROPEAN RADIOLOGY, 2024, 34 (06) : 3708 - 3718
  • [2] Detection of Bone Marrow Edema in Patients with Osteoid Osteoma Using Three-Material Decomposition with Dual-Layer Spectral CT
    Gassert, Florian T.
    Hammel, Johannes
    Hofmann, Felix C.
    Neumann, Jan
    von Schacky, Claudio E.
    Gassert, Felix G.
    Pfeiffer, Daniela
    Pfeiffer, Franz
    Makowski, Marcus R.
    Woertler, Klaus
    Gersing, Alexandra S.
    Schwaiger, Benedikt J.
    DIAGNOSTICS, 2021, 11 (06)
  • [3] Quantification of the trabecular bone volume fraction for bone marrow dosimetry in molecular radiotherapy by using a dual-energy (SPECT/)CT
    Salas-Ramirez, Maikol
    Tran-Gia, Johannes
    Gbureck, Uwe
    Kosmala, Aleksander
    Lassmann, Michael
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (20)
  • [4] Quantification of the Fat Fraction in the Liver Using Dual-Energy Computed Tomography and Multimaterial Decomposition
    Hur, Bo Yun
    Lee, Jeong Min
    Hyunsik, Woo
    Lee, Kyung Bun
    Joo, Ijin
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 845 - 852
  • [5] Lower limit of iron quantification using dual-energy CT - a phantom study
    Jiang, Xia
    Hintenlang, David E.
    White, Richard D.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 299 - 307
  • [6] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Abbassi, Mashya
    Jain, Ashwin
    Shin, Donghoon
    Arasa, Carlota Andreu
    Li, Baojun
    Anderson, Stephan W.
    LeBedis, Christina A.
    EMERGENCY RADIOLOGY, 2022, 29 (04) : 691 - 696
  • [7] Dual-Energy CT of Material Decomposition Analysis for Detection with Bone Marrow Edema in Patients with Vertebral Compression Fractures
    Akisato, Kyouhei
    Nishihara, Reisuke
    Okazaki, Hajime
    Masuda, Takanori
    Hironobe, Ayako
    Ishizaki, Hiromi
    Shota, Kondo
    Yamaguchi, Hiroshi
    Funama, Yoshinori
    ACADEMIC RADIOLOGY, 2020, 27 (02) : 227 - 232
  • [8] Dual-Energy Computed Tomography for Fat Quantification in the Liver and Bone Marrow: A Literature Review
    Molwitz, Isabel
    Leiderer, Miriam
    Oezden, Cansu
    Yamamura, Jin
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2020, 192 (12): : 1137 - 1152
  • [9] Quantification of bone marrow edema using dual-energy CT at fracture sites in trauma
    Mashya Abbassi
    Ashwin Jain
    Donghoon Shin
    Carlota Andreu Arasa
    Baojun Li
    Stephan W. Anderson
    Christina A. LeBedis
    Emergency Radiology, 2022, 29 : 691 - 696
  • [10] Influence of Radiation Dose and Reconstruction Kernel on Fat Fraction Analysis in Dual-energy CT: A Phantom Study
    Chatzaraki, Vasiliki
    Born, Corinna
    Kubik-Huch, Rahel A.
    Froehlich, Johannes M.
    Thali, Michael J.
    Niemann, Tilo
    IN VIVO, 2021, 35 (06): : 3147 - 3155