Effects of Large-Diameter Rebar Replacement on Seismic Behavior of Precast Concrete Columns with Grouted Sleeve Connections

被引:4
|
作者
Wang, Qiang [1 ,2 ,3 ]
Qin, Weiyang [1 ]
Lu, Chunling [1 ]
机构
[1] Guilin Univ Technol, GuangXi Key Lab New Energy & Bldg Energy Saving, Guilin 541004, Peoples R China
[2] Guilin Univ Technol, Coll Civil Engn & Architecture, Guilin 541004, Peoples R China
[3] Guilin Univ Technol, Collaborat Innovat Ctr Explorat Hidden Nonferrous, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
diameter of rebar; precast concrete column; seismic behavior; test; grouted sleeve; PERFORMANCE; DESIGN;
D O I
10.3390/buildings13030706
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Congested reinforcement may lead to difficulties with compacting concrete and reduce the connection efficiency. To overcome this problem, using large-diameter longitudinal rebar to replace medium-diameter longitudinal rebar to reduce the number of longitudinal rebars may be a useful mean. However, the seismic behavior of precast concrete (PC) columns with different-diameter longitudinal rebars was still unclear. In order to evaluate the influence of large-diameter longitudinal rebar replacement on the seismic behavior of PC columns, a series of large-scale reinforced concrete (RC) columns adopting similar concrete strength, longitudinal rebar ratio, and transverse rebar ratio was fabricated and tested. Six of the columns were prefabricated with grouted sleeve connections and the remaining two were cast in place (CIP) for reference. The longitudinal rebar diameter varied from 18 mm to 32 mm. A low-cycle reversed horizontal load was applied to study their seismic performance, including failure modes, load-bearing capacity, hysteresis behavior, stiffness degeneration, and energy-dissipation capacity. The test results showed that the PC column with large-diameter longitudinal rebar replacement performed similarly to CIP columns in general. The column with large-diameter longitudinal rebar suffered significant bond-slip between longitudinal rebar and concrete, especially for columns with a high axial compressive ratio of 0.6. It may be of detriment to the seismic behavior of the columns to some extent. Additionally, with the increase in the diameter of longitudinal rebar, the ductility and energy-dissipation capacity of PC columns were reduced slightly. In the grouted sleeve region, a local rigid zone was formed, making its overall lateral stiffness higher than that of corresponding CIP columns. It is recommended to extend the strengthening zone, with closer transverse reinforcement, to two times the column depth of the PC columns with grouted sleeve connections, as the plastic hinges may be shifted upward.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Mechanical properties of large-diameter semi-grouted sleeve connections for railway platform canopies
    Lin, Pengzhen
    Hou, Shuailong
    Wang, Yapeng
    STRUCTURES, 2023, 51 : 171 - 184
  • [22] Seismic behaviour of precast column-to-foundation grouted sleeve connections
    Riva, Paolo
    Advances in Engineering Structures, Mechanics & Construction, Proceedings, 2006, 140 : 121 - 128
  • [23] Vehicular impacts on precast concrete bridge piers with grouted sleeve connections
    Sun, Wenbiao
    Yang, Cancan
    Fan, Wei
    Wang, Hongxiang
    Su, Huaxiang
    ENGINEERING STRUCTURES, 2022, 267
  • [24] Seismic behavior of precast reinforced concrete column-to-foundation grouted duct connections
    Hofer, Lorenzo
    Zanini, Mariano Angelo
    Faleschini, Flora
    Toska, Klajdi
    Pellegrino, Carlo
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (12) : 5191 - 5218
  • [25] Shear strength and cracking mechanism of precast bridge columns with grouted sleeve connections
    Han, Qiang
    Li, Xiaopeng
    Xu, Kun
    Lu, Yanqiu
    Du, Xiuli
    Wang, Zhiqiang
    ENGINEERING STRUCTURES, 2021, 230
  • [26] Testing and Analysis of Precast Columns with Grouted Sleeve Connections and Shifted Plastic Hinging
    Haber, Zachary B.
    Mackie, Kevin R.
    Al-Jelawy, Haider M.
    JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (10)
  • [27] Seismic behavior of precast reinforced concrete column-to-foundation grouted duct connections
    Lorenzo Hofer
    Mariano Angelo Zanini
    Flora Faleschini
    Klajdi Toska
    Carlo Pellegrino
    Bulletin of Earthquake Engineering, 2021, 19 : 5191 - 5218
  • [28] Shear Performance of Horizontal Joints in Short Precast Concrete Columns with Sleeve Grouted Connections under Cyclic Loading
    Feng, Bo
    Xiong, Feng
    Liu, Bingyu
    Chen, Jiang
    Zhang, Yiping
    PLOS ONE, 2016, 11 (11):
  • [29] Seismic behavior of large-diameter CFTST column to steel beam connections
    Liu, Jiepeng
    He, Wenrui
    Cheng, Guozhong
    Chen, Y. Frank
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 175
  • [30] Experimental Investigations on the Seismic Behavior of Precast Concrete Columns with Novel Box Connections
    Zhang, Xizhi
    Xu, Shengbo
    Zhang, Shaohua
    Xu, Gaodong
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2020, 14 (02)