Simultaneous determination of procalcitonin and interleukin-6 in human serum samples with a point-of-care biosensing device

被引:8
作者
Tsounidi, Dimitra [1 ]
Tsaousis, Vasileios [2 ]
Xenos, Nikolaos [3 ]
Kroupis, Christos [3 ]
Moutsatsou, Paraskevi [3 ]
Christianidis, Vasileios [4 ]
Goustouridis, Dimitrios [4 ,5 ]
Raptis, Ioannis [4 ,6 ]
Kakabakos, Sotirios [1 ]
Petrou, Panagiota [1 ]
机构
[1] Natl Ctr Sci Res Demokritos, Inst Nucl & Radiol Sci & Technol Energy & Safety, Immunoassays Immunosensors Lab, Bldg 9 Neapoleos 27, Aghia Paraskevi 15341, Paraskevi, Greece
[2] Medicon Hellas SA, Gerakas 15344, Greece
[3] Natl & Kapodistrian Univ Athens, Attikon Univ Gen Hosp, Med Sch, Clin Biochem & Mol Diagnost Lab, Chaidari 12462, Greece
[4] ThetaMetrisis SA, 12132, Athens, SA, Australia
[5] Univ West Att, Dept Elect & Elect Eng, Athens 12244, Greece
[6] Natl Ctr Sci Res Demokritos, Inst Nanosci & Nanotechnol, Aghia Paraskevi 15341, Paraskevi, Greece
关键词
Multi area reflectance spectroscopy; Dual-analyte assay; Point-of-Care device; Procalcitonin; Interleukin-6; DIAGNOSIS; SEPSIS; BIOMARKERS; BACTERIAL; MANAGEMENT; ASSAY; QUANTIFICATION; IMMUNOASSAY; COMBINATION; INFECTIONS;
D O I
10.1016/j.talanta.2023.124403
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous determination of two inflammatory diseases biomarkers, namely procalcitonin (PCT) and interleukin-6 (IL-6), in human serum samples employing a Point-of-Care device based on Multi Area Reflectance Spectroscopy is presented. Dual-analyte detection was achieved using silicon chips with two silicon dioxide areas of different thickness, one functionalized with an antibody specific for PCT and the other with an antibody specific for IL-6. The assay included reaction of immobilized capture antibodies with mixtures of PCT and IL-6 calibrators with the biotinylated detection antibodies, streptavidin and biotinylated-BSA. The reader provided for the automated execution of the assay procedure, as well as for the collection and processing of the reflected light spectrum, the shift of which is correlated to analytes concentration in the sample. The assay was completed in 35 min and the detection limits for PCT and IL-6 were 2.0 and 0.01 ng/mL respectively. The dual-analyte assay was characterized by high reproducibility (the intra-and inter-assay coefficients of variation were less than 10% for both analytes) and accuracy (the percent recovery values ranged from 80 to 113% for both analytes). Moreover, the values determined for the two analytes in human serum samples with the assay developed were in good agreement with the values determined for the same samples by clinical laboratory methods. These results support the potential of the proposed biosensing device application for inflammatory biomarkers determination at the Point-of-Need.
引用
收藏
页数:9
相关论文
共 62 条
[1]   Fast Deoxynivalenol Determination in Cereals Using a White Light Reflectance Spectroscopy Immunosensor [J].
Anastasiadis, Vasileios ;
Raptis, Ioannis ;
Economou, Anastasios ;
Kakabakos, Sotirios E. ;
Petrou, Panagiota S. .
BIOSENSORS-BASEL, 2020, 10 (11)
[2]   Multiplexed mycotoxins determination employing white light reflectance spectroscopy and silicon chips with silicon oxide areas of different thickness [J].
Anastasiadis, Vasileios ;
Koukouvinos, Georgios ;
Petrou, Panagiota S. ;
Economou, Anastasios ;
Dekker, James ;
Harjanne, Mikko ;
Heimala, Paivi ;
Goustouridis, Dimitris ;
Raptis, Ioannis ;
Kakabakos, Sotirios E. .
BIOSENSORS & BIOELECTRONICS, 2020, 153
[3]   Label-Free Biosensors for Laboratory-Based Diagnostics of Infections: Current Achievements and New Trends [J].
Andryukov, Boris G. ;
Besednova, Natalya N. ;
Romashko, Roman V. ;
Zaporozhets, Tatyana S. ;
Efimov, Timofey A. .
BIOSENSORS-BASEL, 2020, 10 (02)
[4]   Rapid Detection of Salmonella typhimurium in Drinking Water by a White Light Reflectance Spectroscopy Immunosensor [J].
Angelopoulou, Michailia ;
Tzialla, Konstantina ;
Voulgari, Angeliki ;
Dikeoulia, Mary ;
Raptis, Ioannis ;
Kakabakos, Sotirios Elias ;
Petrou, Panagiota .
SENSORS, 2021, 21 (08)
[5]   Biomarkers for Sepsis: What Is and What Might Be? [J].
Biron, Bethany M. ;
Ayala, Alfred ;
Lomas-Neira, Joanne L. .
BIOMARKER INSIGHTS, 2015, 10 :7-17
[6]   Rapid diagnosis of sepsis [J].
Bloos, Frank ;
Reinhart, Konrad .
VIRULENCE, 2014, 5 (01) :154-160
[7]   Potential biomarkers for effective screening of neonatal sepsis infections: An overview [J].
Chauhan, Nidhi ;
Tiwari, Sukirti ;
Jain, Utkarsh .
MICROBIAL PATHOGENESIS, 2017, 107 :234-242
[8]   Biomarkers during COVID-19: Mechanisms of Change and Implications for Patient Outcomes [J].
Chen, Cheng-Han ;
Lin, Sheng-Wen ;
Shen, Ching-Fen ;
Hsieh, Kai-Sheng ;
Cheng, Chao-Min .
DIAGNOSTICS, 2022, 12 (02)
[9]   Multiplex Serum Cytokine Immunoassay Using Nanoplasmonic Biosensor Microarrays [J].
Chen, Pengyu ;
Chung, Meng Ting ;
McHugh, Walker ;
Nidetz, Robert ;
Li, Yuwei ;
Fu, Jianping ;
Cornell, Timothy T. ;
Shanley, Thomas P. ;
Kurabayashi, Katsuo .
ACS NANO, 2015, 9 (04) :4173-4181
[10]   Fiber optic nanogold-linked immunosorbent assay for rapid detection of procalcitonin at femtomolar concentration level [J].
Chiang, Chang-Yue ;
Huang, Tze-Ta ;
Wang, Chih-Hui ;
Huang, Chun-Jen ;
Tsai, Tsung-Heng ;
Yu, Sung-Nien ;
Chen, Ying-Ting ;
Hong, Shih-Wei ;
Hsu, Chia-Wei ;
Chang, Ting-Chou ;
Chau, Lai-Kwan .
BIOSENSORS & BIOELECTRONICS, 2020, 151