Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance

被引:5
作者
Topriceanu, Constantin-Cristian [1 ,2 ,5 ]
Fornasiero, Massimiliano [3 ]
Seo, Han [4 ]
Webber, Matthew [1 ,2 ,4 ,5 ]
Keenan, Kathryn E. E. [6 ]
Stupic, Karl F. F. [6 ]
Bruehl, Ruediger [7 ]
Ittermann, Bernd [7 ]
Price, Kirsty [8 ]
McGrath, Louise [8 ]
Pang, Wenjie [9 ]
Hughes, Alun D. D. [2 ,5 ]
Nezafat, Reza [10 ]
Kellman, Peter [11 ]
Pierce, Iain [1 ,2 ]
Moon, James C. C. [1 ,2 ]
Captur, Gabriella [2 ,4 ,5 ,12 ]
机构
[1] Barts Hlth NHS Trust, Barts Heart Ctr, ECIA 7BE, London, England
[2] UCL, Inst Cardiovasc Sci, Huntley St, London WC1E 6DD, England
[3] UCL Med Sch, 74 Huntley St, London WC1E 6DE, England
[4] Royal Free London NHS Fdn Trust, Ctr Inherited Heart Muscle Condit, Dept Cardiol, Pond St, London NW3 2QG, England
[5] UCL, Med Res Council Unit Lifelong Hlth & Ageing, 1-19 Torrington Pl, London WC1E 7HB, England
[6] NIST, 325 Broadway, Boulder, CO 80305 USA
[7] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[8] UCL Bloomsbury Ctr Clin Phenotyping, London WC1E 6HX, England
[9] Resonance Hlth RH, 141 Burswood Rd, Burswood, WA 6100, Australia
[10] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Med, Cardiovasc Div, 330 Brookline Ave, Boston, MA 02215 USA
[11] NHLBI, NIH, Bethesda, MD 20892 USA
[12] UCL, Inst Cardiovasc Sci, Inherited Heart Muscle Condit, Gower St, London WC1E 6BT, England
基金
英国医学研究理事会; 英国经济与社会研究理事会; 欧盟地平线“2020”;
关键词
T-1; mapping; T-2; Phantom; Quality control; MRI; FIELD; ECHO; SEQUENCES; VALUES; 3T;
D O I
10.1186/s12968-023-00926-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionA long T-2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T-2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T-2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T-2 mapping in CMR.AimTo fabricate and assess a phantom dedicated to the quality assurance of T-2 mapping in CMR.MethodA T-2 mapping phantom was manufactured to contain 9 T-1 and T-2 (T-1|T-2) tubes to mimic clinically relevant native and post-contrast T-2 in myocardium across the health to inflammation spectrum (i.e., 43-74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom's structural integrity, B-0 and B-1 uniformity using field maps, and temperature dependence. Baseline reference T-1|T-2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T-1|T-2 was determined by repeated T-1|T-2 mapping of the phantom at baseline and at 12 months.ResultsThe phantom embodies 9 internal agarose-containing T-1|T-2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T-2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to <= 7.2 ms [< 14.7%] for estimated T-2 by balanced steady-state free precession T-2 mapping compared to reference SE T-2 with the exception of the post-contrast tube of ultra-low T-1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B-0 and B-1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13-38 degrees C range confirmed the greater stability of shorter vs longer T-1|T-2 tubes. Excellent long-term (12-month) reproducibility of measured T-1|T-2 was demonstrated across both field strengths (all coefficients of variation < 1.38%).ConclusionThe T-2 mapping phantom demonstrates excellent structural integrity, B-0 and B-1 uniformity, and reproducibility of its internal tube T-1|T-2 out to 1 year. This device may now be mass-produced to support the quality assurance of T-2 mapping in CMR.
引用
收藏
页数:14
相关论文
共 50 条
[41]   Myocardial T1 and T2 Mapping by Magnetic Resonance in Patients With Immune Checkpoint Inhibitor-Associated Myocarditis [J].
Thavendiranathan, Paaladinesh ;
Zhang, Lili ;
Zafar, Amna ;
Drobni, Zsofia D. ;
Mahmood, Syed S. ;
Cabral, Marcella ;
Awadalla, Magid ;
Nohria, Anju ;
Zlotoff, Daniel A. ;
Thuny, Franck ;
Heinzerling, Lucie M. ;
Barac, Ana ;
Sullivan, Ryan J. ;
Chen, Carol L. ;
Gupta, Dipti ;
Kirchberger, Michael C. ;
Hartmann, Sarah E. ;
Weinsaft, Jonathan W. ;
Gilman, Hannah K. ;
Rizvi, Muhammad A. ;
Kovacina, Bojan ;
Michel, Caroline ;
Sahni, Gagan ;
Gonzalez-Mansilla, Ana ;
Calles, Antonio ;
Fernandez-Aviles, Francisco ;
Mahmoudi, Michael ;
Reynolds, Kerry L. ;
Ganatra, Sarju ;
Jose Gavira, Juan ;
Salterain Gonzalez, Nahikari ;
de Yebenes Castro, Manuel Garcia ;
Kwong, Raymond Y. ;
Jerosch-Herold, Michael ;
Coelho-Filho, Otavio R. ;
Afilalo, Jonathan ;
Zatarain-Nicolas, Eduardo ;
Baksi, A. John ;
Wintersperger, Bernd J. ;
Calvillo-Arguelles, Oscar ;
Ederhy, Stephane ;
Yang, Eric H. ;
Lyon, Alexander R. ;
Fradley, Michael G. ;
Neilan, Tomas G. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (12) :1503-1516
[42]   Diagnostic Value of Cardiovascular Magnetic Resonance T1 and T2 Mapping in Acute Myocarditis: A Systematic Literature Review [J].
Gaizauskiene, Karolina ;
Leketaite, Kamile ;
Glaveckaite, Sigita ;
Valeviciene, Nomeda .
MEDICINA-LITHUANIA, 2024, 60 (07)
[43]   An Accurate Estimation of T2*Mapping for Fast Magnetic Resonance Imaging [J].
Yang, Jie ;
Zhang, Zhicheng ;
Zhu, Yanchun ;
Xie, Yaoqin .
THIRD INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE (ISICDM 2019), 2019, :335-342
[44]   Repeatability of radiomic features in myocardial T1 and T2 mapping [J].
Manzke, Mathias ;
Laqua, Fabian C. ;
Boettcher, Benjamin ;
Klemenz, Ann-Christin ;
Weber, Marc-Andre ;
Baessler, Bettina ;
Meinel, Felix G. .
EUROPEAN RADIOLOGY, 2025, 35 (03) :1570-1582
[45]   MR imaging assessment of myocardial edema with T2 mapping [J].
Montant, P. ;
Sigovan, M. ;
Revel, D. ;
Douek, P. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (09) :885-890
[46]   Robust Myocardial T2 and T2* Mapping at 3T Using Image-Based Shimming [J].
Zaman, Arshad ;
Higgins, David M. ;
Motwani, Manish ;
Kidambi, Ananth ;
Kouwenhoven, Marc ;
Kozerke, Sebastian ;
Greenwood, John P. ;
Plein, Sven .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (04) :1013-1020
[47]   Biochemical magnetic resonance imaging of knee articular cartilage: T1rho and T2 mapping as cartilage degeneration biomarkers [J].
Le, Jenna ;
Peng, Qi ;
Sperling, Karen .
MUSCULOSKELETAL REPAIR AND REGENERATION, 2016, 1383 :34-42
[48]   Deep learning reconstruction for cardiac magnetic resonance fingerprinting T1 and T2 mapping [J].
Hamilton, Jesse I. ;
Currey, Danielle ;
Rajagopalan, Sanjay ;
Seiberlich, Nicole .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (04) :2127-2135
[49]   On Using T2 to Assess Extrinsic Magnetic Field Inhomogeneity Effects Myocardial Siderosis on T2* Measurements in in Thalassemia [J].
He, Taigang ;
Smith, Gillian C. ;
Gatehouse, Peter D. ;
Mohiaddin, Raad H. ;
Firmin, David N. ;
Pennell, Dudley J. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (03) :501-506
[50]   On the accuracy and precision of cardiac magnetic resonance T2 mapping: A high-resolution radial study using adiabatic T2 preparation at 3T [J].
Bano, Wajiha ;
Feliciano, Helene ;
Coristine, Andrew J. ;
Stuber, Matthias ;
van Heeswijk, Ruud B. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) :159-169