Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance

被引:5
作者
Topriceanu, Constantin-Cristian [1 ,2 ,5 ]
Fornasiero, Massimiliano [3 ]
Seo, Han [4 ]
Webber, Matthew [1 ,2 ,4 ,5 ]
Keenan, Kathryn E. E. [6 ]
Stupic, Karl F. F. [6 ]
Bruehl, Ruediger [7 ]
Ittermann, Bernd [7 ]
Price, Kirsty [8 ]
McGrath, Louise [8 ]
Pang, Wenjie [9 ]
Hughes, Alun D. D. [2 ,5 ]
Nezafat, Reza [10 ]
Kellman, Peter [11 ]
Pierce, Iain [1 ,2 ]
Moon, James C. C. [1 ,2 ]
Captur, Gabriella [2 ,4 ,5 ,12 ]
机构
[1] Barts Hlth NHS Trust, Barts Heart Ctr, ECIA 7BE, London, England
[2] UCL, Inst Cardiovasc Sci, Huntley St, London WC1E 6DD, England
[3] UCL Med Sch, 74 Huntley St, London WC1E 6DE, England
[4] Royal Free London NHS Fdn Trust, Ctr Inherited Heart Muscle Condit, Dept Cardiol, Pond St, London NW3 2QG, England
[5] UCL, Med Res Council Unit Lifelong Hlth & Ageing, 1-19 Torrington Pl, London WC1E 7HB, England
[6] NIST, 325 Broadway, Boulder, CO 80305 USA
[7] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[8] UCL Bloomsbury Ctr Clin Phenotyping, London WC1E 6HX, England
[9] Resonance Hlth RH, 141 Burswood Rd, Burswood, WA 6100, Australia
[10] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Med, Cardiovasc Div, 330 Brookline Ave, Boston, MA 02215 USA
[11] NHLBI, NIH, Bethesda, MD 20892 USA
[12] UCL, Inst Cardiovasc Sci, Inherited Heart Muscle Condit, Gower St, London WC1E 6BT, England
基金
英国医学研究理事会; 英国经济与社会研究理事会; 欧盟地平线“2020”;
关键词
T-1; mapping; T-2; Phantom; Quality control; MRI; FIELD; ECHO; SEQUENCES; VALUES; 3T;
D O I
10.1186/s12968-023-00926-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionA long T-2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T-2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T-2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T-2 mapping in CMR.AimTo fabricate and assess a phantom dedicated to the quality assurance of T-2 mapping in CMR.MethodA T-2 mapping phantom was manufactured to contain 9 T-1 and T-2 (T-1|T-2) tubes to mimic clinically relevant native and post-contrast T-2 in myocardium across the health to inflammation spectrum (i.e., 43-74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom's structural integrity, B-0 and B-1 uniformity using field maps, and temperature dependence. Baseline reference T-1|T-2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T-1|T-2 was determined by repeated T-1|T-2 mapping of the phantom at baseline and at 12 months.ResultsThe phantom embodies 9 internal agarose-containing T-1|T-2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T-2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to <= 7.2 ms [< 14.7%] for estimated T-2 by balanced steady-state free precession T-2 mapping compared to reference SE T-2 with the exception of the post-contrast tube of ultra-low T-1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B-0 and B-1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13-38 degrees C range confirmed the greater stability of shorter vs longer T-1|T-2 tubes. Excellent long-term (12-month) reproducibility of measured T-1|T-2 was demonstrated across both field strengths (all coefficients of variation < 1.38%).ConclusionThe T-2 mapping phantom demonstrates excellent structural integrity, B-0 and B-1 uniformity, and reproducibility of its internal tube T-1|T-2 out to 1 year. This device may now be mass-produced to support the quality assurance of T-2 mapping in CMR.
引用
收藏
页数:14
相关论文
共 50 条
[31]   Biochemical analysis of the articular disc of the temporomandibular joint with magnetic resonance T2 mapping: a feasibility study [J].
Schmid-Schwap, Martina ;
Bristela, Margit ;
Pittschieler, Elisabeth ;
Skolka, Astrid ;
Szomolanyi, Pavol ;
Weber, Michael ;
Piehslinger, Eva ;
Trattnig, Siegfried .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (07) :1865-1871
[32]   T1ρ, T2 and T2*mapping of lumbar intervertebral disc degeneration: a comparison study [J].
Yang, Li ;
Sun, Cong ;
Gong, Tao ;
Li, Quanlin ;
Chen, Xin ;
Zhang, Xinjuan .
BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
[33]   Correlations of T2*Mapping with Delayed Gadolinium Enhancement in Chronic Myocardial Infarction Magnetic Resonance Imaging [J].
Mohammadzadeh, Ali ;
Maleki, Zahra ;
Nahardani, Ali ;
Mohammadzadeh, Maryam .
IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (04)
[34]   Application of quantitative T1, T2 and T2*mapping magnetic resonance imaging in cartilage degeneration of the shoulder joint [J].
Cao, Guijuan ;
Gao, Shubo ;
Xiong, Bin .
SCIENTIFIC REPORTS, 2023, 13 (01)
[35]   The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions [J].
Juras, Vladimir ;
Schreiner, Markus ;
Laurent, Didier ;
Zbyn, Stefan ;
Mlynarik, Vladimir ;
Szomolanyi, Pavol ;
Hager, Benedikt ;
Scotti, Celeste ;
Goldhahn, Jorg ;
Heule, Rahel ;
Bieri, Oliver ;
Trattnig, Siegfried .
MAGNETIC RESONANCE IMAGING, 2019, 55 :86-92
[36]   Rapid Radial T1 and T2 Mapping of the Hip Articular Cartilage With Magnetic Resonance Fingerprinting [J].
Cloos, Martijn A. ;
Asslander, Jakob ;
Abbas, Batool ;
Fishbaugh, James ;
Babb, James S. ;
Gerig, Guido ;
Lattanzi, Riccardo .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (03) :810-815
[37]   Quantitative Mapping of T2 Using Partial Spoiling [J].
Bieri, Oliver ;
Scheffler, Klaus ;
Welsch, Goetz H. ;
Trattnig, S. ;
Mamisch, Tallal C. ;
Ganter, Carl .
MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) :410-418
[38]   T2 mapping of cartilage in the equine distal interphalangeal joint with corresponding histology using 0.27 T and 3.0 T magnetic resonance imaging [J].
Baker, Melissa Eve ;
Kershaw, Lucy Elizabeth ;
Carstens, Ann ;
Daniel, Carola Riccarda ;
Brown, Helen ;
Roberts, Steve ;
Taylor, Sarah Elizabeth .
EQUINE VETERINARY JOURNAL, 2023, 55 (05) :843-852
[39]   Myocardial Tissue Characterization by Magnetic Resonance Imaging Novel Applications of T1 and T2 Mapping [J].
Ferreira, Vanessa M. ;
Piechnik, Stefan K. ;
Robson, Matthew D. ;
Neubauer, Stefan ;
Karamitsos, Theodoros D. .
JOURNAL OF THORACIC IMAGING, 2014, 29 (03) :147-154
[40]   Diagnostic performance of cardiovascular magnetic resonance native T1 and T2 mapping in pediatric patients with acute myocarditis [J].
Cornicelli, Matthew D. ;
Rigsby, Cynthia K. ;
Rychlik, Karen ;
Pahl, Elfriede ;
Robinson, Joshua D. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)