Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance

被引:5
作者
Topriceanu, Constantin-Cristian [1 ,2 ,5 ]
Fornasiero, Massimiliano [3 ]
Seo, Han [4 ]
Webber, Matthew [1 ,2 ,4 ,5 ]
Keenan, Kathryn E. E. [6 ]
Stupic, Karl F. F. [6 ]
Bruehl, Ruediger [7 ]
Ittermann, Bernd [7 ]
Price, Kirsty [8 ]
McGrath, Louise [8 ]
Pang, Wenjie [9 ]
Hughes, Alun D. D. [2 ,5 ]
Nezafat, Reza [10 ]
Kellman, Peter [11 ]
Pierce, Iain [1 ,2 ]
Moon, James C. C. [1 ,2 ]
Captur, Gabriella [2 ,4 ,5 ,12 ]
机构
[1] Barts Hlth NHS Trust, Barts Heart Ctr, ECIA 7BE, London, England
[2] UCL, Inst Cardiovasc Sci, Huntley St, London WC1E 6DD, England
[3] UCL Med Sch, 74 Huntley St, London WC1E 6DE, England
[4] Royal Free London NHS Fdn Trust, Ctr Inherited Heart Muscle Condit, Dept Cardiol, Pond St, London NW3 2QG, England
[5] UCL, Med Res Council Unit Lifelong Hlth & Ageing, 1-19 Torrington Pl, London WC1E 7HB, England
[6] NIST, 325 Broadway, Boulder, CO 80305 USA
[7] Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
[8] UCL Bloomsbury Ctr Clin Phenotyping, London WC1E 6HX, England
[9] Resonance Hlth RH, 141 Burswood Rd, Burswood, WA 6100, Australia
[10] Harvard Med Sch, Beth Israel Deaconess Med Ctr, Dept Med, Cardiovasc Div, 330 Brookline Ave, Boston, MA 02215 USA
[11] NHLBI, NIH, Bethesda, MD 20892 USA
[12] UCL, Inst Cardiovasc Sci, Inherited Heart Muscle Condit, Gower St, London WC1E 6BT, England
基金
英国医学研究理事会; 英国经济与社会研究理事会; 欧盟地平线“2020”;
关键词
T-1; mapping; T-2; Phantom; Quality control; MRI; FIELD; ECHO; SEQUENCES; VALUES; 3T;
D O I
10.1186/s12968-023-00926-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionA long T-2 relaxation time can reflect oedema, and myocardial inflammation when combined with increased plasma troponin levels. Cardiovascular magnetic resonance (CMR) T-2 mapping therefore has potential to provide a key diagnostic and prognostic biomarkers. However, T-2 varies by scanner, software, and sequence, highlighting the need for standardization and for a quality assurance system for T-2 mapping in CMR.AimTo fabricate and assess a phantom dedicated to the quality assurance of T-2 mapping in CMR.MethodA T-2 mapping phantom was manufactured to contain 9 T-1 and T-2 (T-1|T-2) tubes to mimic clinically relevant native and post-contrast T-2 in myocardium across the health to inflammation spectrum (i.e., 43-74 ms) and across both field strengths (1.5 and 3 T). We evaluated the phantom's structural integrity, B-0 and B-1 uniformity using field maps, and temperature dependence. Baseline reference T-1|T-2 were measured using inversion recovery gradient echo and single-echo spin echo (SE) sequences respectively, both with long repetition times (10 s). Long-term reproducibility of T-1|T-2 was determined by repeated T-1|T-2 mapping of the phantom at baseline and at 12 months.ResultsThe phantom embodies 9 internal agarose-containing T-1|T-2 tubes doped with nickel di-chloride (NiCl2) as the paramagnetic relaxation modifier to cover the clinically relevant spectrum of myocardial T-2. The tubes are surrounded by an agarose-gel matrix which is doped with NiCl2 and packed with high-density polyethylene (HDPE) beads. All tubes at both field strengths, showed measurement errors up to <= 7.2 ms [< 14.7%] for estimated T-2 by balanced steady-state free precession T-2 mapping compared to reference SE T-2 with the exception of the post-contrast tube of ultra-low T-1 where the deviance was up to 16 ms [40.0%]. At 12 months, the phantom remained free of air bubbles, susceptibility, and off-resonance artifacts. The inclusion of HDPE beads effectively flattened the B-0 and B-1 magnetic fields in the imaged slice. Independent temperature dependency experiments over the 13-38 degrees C range confirmed the greater stability of shorter vs longer T-1|T-2 tubes. Excellent long-term (12-month) reproducibility of measured T-1|T-2 was demonstrated across both field strengths (all coefficients of variation < 1.38%).ConclusionThe T-2 mapping phantom demonstrates excellent structural integrity, B-0 and B-1 uniformity, and reproducibility of its internal tube T-1|T-2 out to 1 year. This device may now be mass-produced to support the quality assurance of T-2 mapping in CMR.
引用
收藏
页数:14
相关论文
共 50 条
[21]   Myocardial T1 and T2 Mapping: Techniques and Clinical Applications [J].
Kim, Pan Ki ;
Hong, Yoo Jin ;
Im, Dong Jin ;
Suh, Young Joo ;
Park, Chul Hwan ;
Kim, Jin Young ;
Chang, Suyon ;
Lee, Hye-Jeong ;
Hur, Jin ;
Kim, Young Jin ;
Choi, Byoung Wook .
KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (01) :113-131
[22]   Application of magnetic resonance T2 mapping in the temporomandibular joints [J].
Cao, Yang ;
Xia, Chunchao ;
Wang, Si ;
He, Shushu ;
Wamalwa, Peter ;
Chen, Song .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (05) :644-649
[23]   Fat-suppressed T2 mapping of human knee femoral articular cartilage: comparison with conventional T2 mapping [J].
Kim, Bo Ram ;
Yoo, Hye Jin ;
Chae, Hee-Dong ;
Hong, Sung Hwan ;
Choi, Ja-Young .
BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
[24]   Myocardial T2* Mapping with Ultrahigh Field Magnetic Resonance: Physics and Frontier Applications [J].
Huelnhagen, Till ;
Paul, Katharina ;
Ku, Min-Chi ;
Duarte, Teresa Serradas ;
Niendorf, Thoralf .
FRONTIERS IN PHYSICS, 2017, 5
[25]   T2 mapping in patellar chondromalacia [J].
Ruiz Santiago, Fernando ;
Pozuelo Calvo, Rocio ;
Almansa Lopez, Julio ;
Guzman Alvarez, Luis ;
Castellano Garcia, Maria del Mar .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) :984-988
[26]   T2 Mapping in Prostate Cancer [J].
Mai, Julia ;
Abubrig, Mohamed ;
Lehmann, Thomas ;
Hilbert, Tom ;
Weiland, Elisabeth ;
Grimm, Marc O. ;
Teichgraeber, Ulf ;
Franiel, Tobias .
INVESTIGATIVE RADIOLOGY, 2019, 54 (03) :146-152
[27]   Myocardial T2 Mapping in Patients With Hypertrophic Cardiomyopathy [J].
Amano, Yasuo ;
Yanagisawa, Fumi ;
Tachi, Masaki ;
Hashimoto, Hidenobu ;
Imai, Shogo ;
Kumita, Shinichiro .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) :344-348
[28]   T2 mapping in myocardial disease: a comprehensive review [J].
O'Brien, Aaron T. ;
Gil, Katarzyna E. ;
Varghese, Juliet ;
Simonetti, Orlando P. ;
Zareba, Karolina M. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
[29]   T2 mapping cardiovascular magnetic resonance identifies the presence of myocardial inflammation in patients with dilated cardiomyopathy as compared to endomyocardial biopsy [J].
Spieker, M. ;
Katsianos, E. ;
Gastl, M. ;
Behm, P. ;
Horn, P. ;
Jacoby, C. ;
Schnackenburg, B. ;
Reinecke, P. ;
Kelm, M. ;
Westenfeld, R. ;
Boenner, F. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2018, 19 (05) :574-582
[30]   Black blood myocardial T2 mapping [J].
Wang, Chengyan ;
Jang, Jihye ;
Neisius, Ulf ;
Nezafat, Maryam ;
Fahmy, Ahmed ;
Kang, Jinkyu ;
Rodriguez, Jennifer ;
Goddu, Beth ;
Pierce, Patrick ;
Berg, Sophie ;
Zhang, Jue ;
Wang, Xiaoying ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) :153-166