Characterization of the sensitivity of a surface plasmon resonance (SPR) fiber optic sensor composed of silver and nickel oxide layers

被引:2
|
作者
Kapoor, Vicky [1 ]
Sharma, Navneet K. [2 ]
机构
[1] Univ Delhi, Dept Phys, Keshav Mahavidyalaya, Delhi, India
[2] Jaypee Inst Informat Technol, Dept Phys & Mat Sci & Engn, A-10,Sect 62, Noida 201309, India
关键词
Nickel oxide; optical fiber; sensor; silver; surface plasmon resonance (SPR); P-TYPE NIO; SENSING STRUCTURE; GAS; ENHANCEMENT; FILMS;
D O I
10.1080/10739149.2022.2099889
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A surface plasmon resonance based fiber optic sensor is presented experimentally using silver and nickel oxide layers. The sensitivity analysis of the sensor has been carried out. Also, the influence of the nickel oxide layer thickness upon the sensitivity has been examined. The sensitivity is enhanced with the increase in thickness of nickel oxide layer up to 10 nm and decreased at larger values. The sensor composed of 40 nm silver-10 nm nickel oxide layers provides the highest sensitivity.
引用
收藏
页码:99 / 108
页数:10
相关论文
共 50 条
  • [21] High sensitivity surface plasmon resonance (SPR) refractive index sensor in 1.5 μm
    Ahmad, H.
    Amiri, I. S.
    Soltanian, M. R. K.
    Narimani, Leila
    Zakaria, R.
    Ismail, M. F.
    Thambiratnam, K.
    MATERIALS EXPRESS, 2017, 7 (02) : 145 - 150
  • [22] Surface plasmon resonance-based fiber optic sensor utilizing tin oxide and zinc sulfide: An experimental analysis
    Kapoor, Vicky
    Sharma, Navneet K.
    SURFACE AND INTERFACE ANALYSIS, 2024, 56 (09) : 597 - 602
  • [23] Localized surface plasmon resonance based fiber optic sensor with nanoparticles
    Rani, Mahima
    Sharma, Navneet K.
    Sajal, Vivek
    OPTICS COMMUNICATIONS, 2013, 292 : 92 - 100
  • [24] Influence of dopants on the performance of a fiber optic surface plasmon resonance sensor
    Sharma, Anuj K.
    Rajan
    Gupta, B. D.
    OPTICS COMMUNICATIONS, 2007, 274 (02) : 320 - 326
  • [25] A study of surface plasmon resonance (SPR) based biosensor with improved sensitivity
    Kushwaha, Angad S.
    Kumar, Anil
    Kumar, Rajeev
    Srivastava, S. K.
    PHOTONICS AND NANOSTRUCTURES-FUNDAMENTALS AND APPLICATIONS, 2018, 31 : 99 - 106
  • [26] A self-validating fiber-optic surface plasmon resonance (FO-SPR) sensor system
    Chopra, Aditi
    Mohanta, Girish C.
    Bhatti, Shwinky
    Sarkar, Sudipta
    PLASMONICS IN BIOLOGY AND MEDICINE XIX, 2022, 11978
  • [27] Theoretical Study of Surface Plasmon Resonance-based Fiber Optic Sensor Utilizing Cobalt and Nickel Films
    Shukla, Sarika
    Sharma, Navneet K.
    Sajal, Vivek
    BRAZILIAN JOURNAL OF PHYSICS, 2016, 46 (03) : 288 - 293
  • [28] Theoretical Study of Surface Plasmon Resonance-based Fiber Optic Sensor Utilizing Cobalt and Nickel Films
    Sarika Shukla
    Navneet K. Sharma
    Vivek Sajal
    Brazilian Journal of Physics, 2016, 46 : 288 - 293
  • [29] Gold nanoparticles (AuNPs) and graphene oxide heterostructures with gold film coupling for an enhanced sensitivity surface plasmon resonance (SPR) fiber sensor
    Zhao, Zhou-hao
    Wang, Qi
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2022, 50 (05) : 530 - 542
  • [30] OPTIMIZATION OF THE GRAPHENE-SILVER BASED SURFACE PLASMON RESONANCE (SPR) SENSOR
    Benaziez, S.
    Dibi, Z.
    Benaziez, N.
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2018, 80 (02): : 87 - 100