Treatment of basilar artery aneurysms with two braided stents: Two centers experience of low-profile visualized intraluminal support stents versus Pipeline flow diverters

被引:0
|
作者
Luo, Bin [1 ]
Wang, Chao [2 ,3 ,4 ]
Liu, Jian [2 ,3 ,4 ]
Zhang, Yisen [2 ,3 ,4 ]
Wang, Kun [2 ,3 ,4 ]
Li, Wenqiang [2 ,3 ,4 ]
Zhang, Ying [2 ,3 ,4 ]
机构
[1] Peking Univ Int Hosp, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
[3] Capital Med Univ, Beijing Neurosurg Inst, Dept Neurosurg, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
[4] Capital Med Univ, Beijing Tiantan Hosp, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
基金
中国国家自然科学基金;
关键词
Intracranial aneurysm; stent; basilar artery; treatment; SINGLE-CENTER EXPERIENCE; EMBOLIZATION;
D O I
10.1177/19714009241242638
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Both low-profile visualized intraluminal support (LVIS)stents and Pipeline flow diverters (FDs) are therapeutic strategies for basilar artery (BA) aneurysms, but they have not been directly compared.Methods A total of 132 consecutive patients with 139 BA aneurysms treated with either LVIS stent or Pipeline FDs were analyzed. Propensity score matching (PSM) was used to control for age, sex, hypertension, aneurysm size, shape, location, and duration of follow-up. The treatment results of these two braided stents were compared.Results LVIS stent was placed in 88 (63.3%) and Pipeline FDs in 51 (36.7%) procedures. Patients with Pipeline FDs tended to be younger and have less hypertension, whereas aneurysms had larger aneurysm size. After PSM, similar complete or near-complete occlusion rates (76.7% vs 73.3%, p = .766) and favorable functional outcomes (86.7% vs 90.0%, p = 1) were achieved in patients treated with LVIS stents and Pipeline FDs, respectively. Further comparisons were conducted at three different locations (basilar apex/basilar trunk/vertebrobasilar artery junction [VBJ]) separately, and the results showed a higher complete or near-complete aneurysm occlusion rate after Pipeline FD treatment than LVIS treatment (86.7% vs 59.2%, p = .012) only at VBJ, where a particularly high proportion of non-saccular shape (70.9%) and a male preponderance were noted.Conclusion Both braided stents were effective in the treatment of BA aneurysms, with good occlusion rates and favorable functional outcomes. Pipeline FD achieved a particularly higher aneurysm occlusion rate than LVIS stent at VBJ, where lesions often require reconstruction of the diseased vessel.
引用
收藏
页码:500 / 509
页数:10
相关论文
共 24 条
  • [21] Endovascular Treatment of Wide-Necked Intracranial Aneurysms with the Scepter XC Balloon Catheter, with Low-Profile Visualized Intraluminal Support (LVIS) Jr. Deployment as a "Bailout" Technique
    Wallace, Adam N.
    Kayan, Yasha
    Almandoz, Josser E. Delgado
    Fease, Jennifer L.
    Milner, Anna A.
    Scholz, Jill M.
    WORLD NEUROSURGERY, 2019, 121 : E798 - E807
  • [22] Single Center Experience in Stent-Assisted Coiling of Complex Intracranial Aneurysms Using Low-Profile Stents The ACCLINO® Stent Versus the ACCLINO® Flex Stent
    Dietrich, Philipp
    Gravius, Alica
    Muehl-Benninghaus, Ruben
    Yilmaz, Umut
    Kettner, Michael
    Bomberg, Hagen
    Reith, Wolfgang
    Simgen, Andreas
    CLINICAL NEURORADIOLOGY, 2021, 31 (01) : 99 - 106
  • [23] Preliminary Experience with Stent-Assisted Coiling of Aneurysms Arising from Small (<2.5 mm) Cerebral Vessels Using The Low-Profile Visualized Intraluminal Support Device
    Wang, C. -C.
    Li, W.
    Feng, Z. -Z.
    Hong, B.
    Xu, Y.
    Liu, J. -M.
    Huang, Q. -H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (06) : 1163 - 1168
  • [24] Utility of bulging technique for endovascular treatment of small and wide-necked aneurysms with a Low-profile Visualized Intraluminal Support (LVIS Jr.) device: A case report and review of the literature
    Inoue, Akihiro
    Tagawa, Masahiko
    Matsumoto, Shirabe
    Nishikawa, Masahiro
    Kusakabe, Kosuke
    Watanabe, Hideaki
    Kunieda, Takeharu
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (02) : 125 - 129