Treatment of basilar artery aneurysms with two braided stents: Two centers experience of low-profile visualized intraluminal support stents versus Pipeline flow diverters

被引:0
|
作者
Luo, Bin [1 ]
Wang, Chao [2 ,3 ,4 ]
Liu, Jian [2 ,3 ,4 ]
Zhang, Yisen [2 ,3 ,4 ]
Wang, Kun [2 ,3 ,4 ]
Li, Wenqiang [2 ,3 ,4 ]
Zhang, Ying [2 ,3 ,4 ]
机构
[1] Peking Univ Int Hosp, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Neurosurg Inst, Dept Intervent Neuroradiol, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
[3] Capital Med Univ, Beijing Neurosurg Inst, Dept Neurosurg, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
[4] Capital Med Univ, Beijing Tiantan Hosp, 119,South 4th Ring West Rd, Beijing 100070, Peoples R China
基金
中国国家自然科学基金;
关键词
Intracranial aneurysm; stent; basilar artery; treatment; SINGLE-CENTER EXPERIENCE; EMBOLIZATION;
D O I
10.1177/19714009241242638
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Background Both low-profile visualized intraluminal support (LVIS)stents and Pipeline flow diverters (FDs) are therapeutic strategies for basilar artery (BA) aneurysms, but they have not been directly compared.Methods A total of 132 consecutive patients with 139 BA aneurysms treated with either LVIS stent or Pipeline FDs were analyzed. Propensity score matching (PSM) was used to control for age, sex, hypertension, aneurysm size, shape, location, and duration of follow-up. The treatment results of these two braided stents were compared.Results LVIS stent was placed in 88 (63.3%) and Pipeline FDs in 51 (36.7%) procedures. Patients with Pipeline FDs tended to be younger and have less hypertension, whereas aneurysms had larger aneurysm size. After PSM, similar complete or near-complete occlusion rates (76.7% vs 73.3%, p = .766) and favorable functional outcomes (86.7% vs 90.0%, p = 1) were achieved in patients treated with LVIS stents and Pipeline FDs, respectively. Further comparisons were conducted at three different locations (basilar apex/basilar trunk/vertebrobasilar artery junction [VBJ]) separately, and the results showed a higher complete or near-complete aneurysm occlusion rate after Pipeline FD treatment than LVIS treatment (86.7% vs 59.2%, p = .012) only at VBJ, where a particularly high proportion of non-saccular shape (70.9%) and a male preponderance were noted.Conclusion Both braided stents were effective in the treatment of BA aneurysms, with good occlusion rates and favorable functional outcomes. Pipeline FD achieved a particularly higher aneurysm occlusion rate than LVIS stent at VBJ, where lesions often require reconstruction of the diseased vessel.
引用
收藏
页码:500 / 509
页数:10
相关论文
共 24 条
  • [1] Endovascular management of ruptured basilar artery dissection with two overlapping Low-profile Visualized Intraluminal Support stents
    Zhang, Xiaoxi
    Li, Wenshuai
    Lv, Nan
    Zhang, Quanzhong
    Huang, Qinghai
    INTERVENTIONAL NEURORADIOLOGY, 2016, 22 (06) : 659 - 661
  • [2] Incomplete stent apposition of low-profile visualized intraluminal support stents in the treatment of cerebral aneurysms
    Zhang, Huan
    Gao, Xiaoping
    Liang, Hui
    Ren, Yi
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (06) : 591 - 597
  • [3] Endovascular treatment of vertebral and basilar artery aneurysms with low-profile visualized intraluminal support device
    Quanlong Hong
    Wenqiang Li
    Jing Ma
    Peng Jiang
    Yisen Zhang
    BMC Neurology, 21
  • [4] Endovascular treatment of vertebral and basilar artery aneurysms with low-profile visualized intraluminal support device
    Hong, Quanlong
    Li, Wenqiang
    Ma, Jing
    Jiang, Peng
    Zhang, Yisen
    BMC NEUROLOGY, 2021, 21 (01)
  • [5] Enterprise stents versus low-profile visualized intraluminal support stents for stent-assisted coiling of unruptured paraclinoid aneurysms
    Wu, Zhi-Ping
    Yin, Jian-Lin
    Liu, Shan-Kai
    Ji, Song
    Liu, Jian-Yu
    Wang, Hai-Lan
    Zhang, Yi-Sheng
    Zhang, Da-Zhong
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (05) : 1855 - 1865
  • [6] Braided stents and their impact in intracranial aneurysm treatment for distal locations: from flow diverters to low profile stents
    Iosif, Christina
    Biondi, Alessandra
    EXPERT REVIEW OF MEDICAL DEVICES, 2019, 16 (03) : 237 - 251
  • [7] Low-Profile Visualized Intraluminal Support Jr Braided Stent Versus Atlas Self-Expandable Stent for Treatment of Intracranial Aneurysms: A Single Center Experience
    Monteiro, Andre
    Cortez, Gustavo M.
    Aghaebrahim, Amin
    Sauvageau, Eric
    Hanel, Ricardo A.
    NEUROSURGERY, 2021, 88 (02) : E170 - E178
  • [8] Comparison of Two Endovascular Interventions with Low-Profile Visualized Intraluminal Support or Pipeline Embolization Device in Middle Cerebral Arterial Aneurysms Patients
    Lv, Zhonghua
    Zhu, Yong
    Wang, Wei
    Wu, Qiangjun
    Li, Wen
    Li, Qiang
    Xu, Liang
    JOURNAL OF INVESTIGATIVE SURGERY, 2021, 34 (06) : 590 - 594
  • [9] Reconstructive endovascular treatment of vertebral artery dissecting aneurysms with the Low-profile Visualized Intraluminal Support (LVIS) device
    Wang, Chuan-Chuan
    Fang, Yi-Bin
    Zhang, Ping
    Zhu, Xuan
    Hong, Bo
    Xu, Yi
    Liu, Jian-Min
    Huang, Qing-Hai
    PLOS ONE, 2017, 12 (06):
  • [10] Intracranial Complex Ruptured Aneurysms Coiled with Overlapping Low-Profile Visualized Intraluminal Support Stents: Another Available Option for Complex Ruptured Intracranial Aneurysms
    Yan, Zhiyuan
    Zheng, Kuang
    Xiong, Ye
    Lan, Fujun
    Wang, Yunhui
    Tan, Xianxi
    Zhong, Ming
    Li, Zequn
    WORLD NEUROSURGERY, 2019, 125 : E22 - E28