Continuous 24-hour intraocular pressure monitoring in normal Chinese adults using a novel contact lens sensor system

被引:3
|
作者
Zhang, Yuning [1 ]
Wei, Yifan [1 ]
Lee, Ching Hymn Christopher [2 ]
Or, Ping Wai [2 ]
Karunaratne, Isuru Kaweendra [2 ]
Deng, Mingjie [1 ]
Yang, Wenxin [1 ]
Chong, Iok Tong [2 ]
Yang, Yangfan [1 ]
Chen, Zidong [1 ]
Fan, Yanmei [1 ]
Lam, David C. C. [2 ]
Yu, Minbin [1 ]
机构
[1] Sun Yat Sen Univ, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
[2] Hong Kong Univ Sci & Technol, Dept Mech & Aerosp Engn, Hong Kong, Peoples R China
关键词
Intraocular pressure; Contact lens; Physiology; NORMAL-TENSION GLAUCOMA; HEALTHY-SUBJECTS; CORNEAL THICKNESS; CIRCADIAN-RHYTHM; PATTERN; POPULATION; POSITION; EYES; IOP;
D O I
10.1136/bjo-2023-323361
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To investigate the physiological nyctohemeral intraocular pressure (IOP) rhythms of normal Chinese adults using a novel contact lens sensor system (CLS) that can output IOP in millimetres of mercury (mm Hg) continuously. Methods Fifty-nine eyes of 59 normal Chinese adults completed 24-hour IOP monitoring using the novel CLS. A descriptive analysis was conducted on the 24-hour IOP mean, peak and acrophase, trough and bathyphase, fluctuation, and mean amplitude of intraocular pressure excursion (MAPE). The continuous data were analysed at several periods (diurnal period, 08:00-20:00 hours; nocturnal period, 22:00-06:00 hours; sleep time, 0:00-06:00 hours), and compared between right and left eyes, males and females, and different age ranges (<30, and >= 30), respectively. Results Normal adults had a lower peak, higher trough, smaller fluctuation and smaller MAPE (p<0.05 for all comparisons) but non-significantly different mean (p=0.695) in the nocturnal period or sleep time compared with the diurnal period. The 24-hour IOP peak and trough showed the frequency of occurrence ranging from 1.69% to 15.25% at an interval of 2 hours. No IOP parameter showed significant difference between right and left eyes (p>0.1 for all comparisons). The male group had larger 24-hour and diurnal IOP fluctuation and MAPE (p<0.05 for all comparisons). Subjects aged 30 or over had higher 24-hour and diurnal mean, higher peak, and larger MAPE (p<0.05 for all comparisons). Conclusion Continuous 24-hour IOP output from the CLS in normal Chinese was stable with a comparable mean level between day and night, as well as scattered acrophase and bathyphase. The 24-hour IOP mean increased with age, and IOP variations were positively correlated to age and male sex.
引用
收藏
页码:1535 / 1542
页数:8
相关论文
共 50 条
  • [31] An Ultrasensitive Contact Lens Sensor Based On Self-Assembly Graphene For Continuous Intraocular Pressure Monitoring
    Liu, Zhiduo
    Wang, Gang
    Ye, Chen
    Sun, Hongyan
    Pei, Weihua
    Wei, Chunrong
    Dai, Wen
    Dou, Zhiqiang
    Sun, Qingyu
    Lin, Cheng-Te
    Wang, Yijun
    Chen, Hongda
    Shen, Guozhen
    ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (29)
  • [32] Factors Associated With 24-Hour Fluctuation of Intraocular Pressure in Normal Tension Glaucoma
    Nakamoto, K.
    Yasuda, N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [33] Efficacy of a Contact Lens Sensor for Monitoring 24-H Intraocular Pressure Related Patterns
    Mansouri, Kaweh
    Weinreb, Robert N.
    Liu, John H. K.
    PLOS ONE, 2015, 10 (05):
  • [34] Effect of carteolol hydrochloride on 24-hour variation of intraocular pressure in normal-tension glaucoma
    Nakamoto, Kenji
    Yasuda, Noriko
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (02) : 140 - 143
  • [35] Effect of carteolol hydrochloride on 24-hour variation of intraocular pressure in normal-tension glaucoma
    Kenji Nakamoto
    Noriko Yasuda
    Japanese Journal of Ophthalmology, 2010, 54 : 140 - 143
  • [36] Topographical Central Island-Like Pattern After 24 Hrs of Continuous Intraocular Pressure Monitoring with a Contact Lens Sensor
    Toshida, Hiroshi
    INTERNATIONAL MEDICAL CASE REPORTS JOURNAL, 2020, 13 : 19 - 26
  • [37] Liquid-alloy-based dual sensing elements contact lens sensor for continuous intraocular pressure monitoring
    Wang, Jun
    Liu, Xiaojun
    Diao, Kuan
    Wang, Shuai
    MEASUREMENT, 2025, 240
  • [38] A wearable contact lens sensor for noninvasive in-situ monitoring of intraocular pressure
    Fan, Yanyan
    Tu, Hailing
    Zhao, Hongbin
    Wei, Feng
    Yang, Yi
    Ren, Tianling
    NANOTECHNOLOGY, 2021, 32 (09)
  • [39] The Role of 24-hour Ambulatory Blood Pressure Monitoring in Hypertensive Patients with Normal-tension Glaucoma
    Marjanovic, Ivan
    Marjanovic, Marija
    Stojanov, Vesna
    Hentova-Sencanic, Paraskeva
    Markovic, Vujica
    Bozic, Marija
    Vukcevic-Milosevic, Gordana
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2015, 143 (9-10) : 525 - 530
  • [40] A capacitor-based sensor and a contact lens sensing system for intraocular pressure monitoring
    Chiou, Jin-Chern
    Huang, Yu-Chieh
    Yeh, Guan-Ting
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (01)