Continuous 24-hour intraocular pressure monitoring in normal Chinese adults using a novel contact lens sensor system

被引:3
|
作者
Zhang, Yuning [1 ]
Wei, Yifan [1 ]
Lee, Ching Hymn Christopher [2 ]
Or, Ping Wai [2 ]
Karunaratne, Isuru Kaweendra [2 ]
Deng, Mingjie [1 ]
Yang, Wenxin [1 ]
Chong, Iok Tong [2 ]
Yang, Yangfan [1 ]
Chen, Zidong [1 ]
Fan, Yanmei [1 ]
Lam, David C. C. [2 ]
Yu, Minbin [1 ]
机构
[1] Sun Yat Sen Univ, Guangdong Prov Key Lab Ophthalmol & Visual Sci, Guangdong Prov Clin Res Ctr Ocular Dis, State Key Lab Ophthalmol,Zhongshan Ophthalm Ctr, Guangzhou, Peoples R China
[2] Hong Kong Univ Sci & Technol, Dept Mech & Aerosp Engn, Hong Kong, Peoples R China
关键词
Intraocular pressure; Contact lens; Physiology; NORMAL-TENSION GLAUCOMA; HEALTHY-SUBJECTS; CORNEAL THICKNESS; CIRCADIAN-RHYTHM; PATTERN; POPULATION; POSITION; EYES; IOP;
D O I
10.1136/bjo-2023-323361
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To investigate the physiological nyctohemeral intraocular pressure (IOP) rhythms of normal Chinese adults using a novel contact lens sensor system (CLS) that can output IOP in millimetres of mercury (mm Hg) continuously. Methods Fifty-nine eyes of 59 normal Chinese adults completed 24-hour IOP monitoring using the novel CLS. A descriptive analysis was conducted on the 24-hour IOP mean, peak and acrophase, trough and bathyphase, fluctuation, and mean amplitude of intraocular pressure excursion (MAPE). The continuous data were analysed at several periods (diurnal period, 08:00-20:00 hours; nocturnal period, 22:00-06:00 hours; sleep time, 0:00-06:00 hours), and compared between right and left eyes, males and females, and different age ranges (<30, and >= 30), respectively. Results Normal adults had a lower peak, higher trough, smaller fluctuation and smaller MAPE (p<0.05 for all comparisons) but non-significantly different mean (p=0.695) in the nocturnal period or sleep time compared with the diurnal period. The 24-hour IOP peak and trough showed the frequency of occurrence ranging from 1.69% to 15.25% at an interval of 2 hours. No IOP parameter showed significant difference between right and left eyes (p>0.1 for all comparisons). The male group had larger 24-hour and diurnal IOP fluctuation and MAPE (p<0.05 for all comparisons). Subjects aged 30 or over had higher 24-hour and diurnal mean, higher peak, and larger MAPE (p<0.05 for all comparisons). Conclusion Continuous 24-hour IOP output from the CLS in normal Chinese was stable with a comparable mean level between day and night, as well as scattered acrophase and bathyphase. The 24-hour IOP mean increased with age, and IOP variations were positively correlated to age and male sex.
引用
收藏
页码:1535 / 1542
页数:8
相关论文
共 50 条
  • [21] Capacitive contact lens sensor for continuous non-invasive intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Lam, David C. C.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 112 - 118
  • [22] A New Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Safety and Tolerability
    Zhang, Yuning
    Wei, Yifan
    Karunaratne, I. K.
    Lee, Ching Hymn Christopher
    Deng, Mingjie
    Chen, Zidong
    Yang, Yangfan
    Chong, Iok Tong
    Lam, David C. C.
    Yu, Minbin
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (10): : 439 - 444
  • [23] Role of 24-Hour Intraocular Pressure Monitoring in Glaucoma Management
    Ho, Chun Hing
    Wong, Jasper K. W.
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [24] 24-hour Intraocular Pressure Fluctuation Monitoring Using an Ocular Telemetry Sensor: Tolerability and Functionality in Healthy Subjects
    De Smedt, Stefan
    Mermoud, Andre
    Schnyder, Corinne
    JOURNAL OF GLAUCOMA, 2012, 21 (08) : 539 - 544
  • [25] Analysis of the diurnal intraocular pressure profile pre and post trabeculectomy using 24-hour monitoring of intraocular pressure
    Ross, Adam H.
    Jackson, Thomas E.
    Wertheim, Michael S.
    Spry, Paul G. D.
    Sparrow, John M.
    Diamond, Jeremy P.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (04) : 400 - 403
  • [26] Intraocular Pressure Fluctuations and 24-Hour Continuous Monitoring for Glaucoma Risk in Wind Instrument Players
    de Crom, Ronald M. P. C.
    Webers, Carroll A. B.
    van Kooten-Noordzij, Marina A. W.
    Michiels, Agnes C.
    Schouten, Jan S. A. G.
    Berendschot, Tos T. J. M.
    Beckers, Henny J. M.
    JOURNAL OF GLAUCOMA, 2017, 26 (10) : 923 - 928
  • [27] Effect of travoprost on 24-hour intraocular pressure in normal tension glaucoma
    Nomura, Yuya
    Nakakura, Shunsuke
    Moriwaki, Mitsuyasu
    Takahashi, Yasuhiro
    Shiraki, Kunihiko
    CLINICAL OPHTHALMOLOGY, 2010, 4 : 643 - 647
  • [28] Assessing the Functionality and Biocompatibility of a Wireless Contact Lens Sensor for 24 hour-intraocular Pressure Monitoring in Volunteers: Preliminary Results
    De Smedt, S. K., Sr.
    Mermoud, A.
    Roy, S.
    Schnyder, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [29] Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients
    Faschinger, C.
    Mossboeck, G.
    OPHTHALMOLOGE, 2010, 107 (10): : 918 - 922
  • [30] Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure
    Dou, Zhiqiang
    Tang, Jun
    Liu, Zhiduo
    Sun, Qigong
    Wang, Yang
    Li, Yamin
    Yuan, Miao
    Wu, Huijuan
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    MICROMACHINES, 2021, 12 (02) : 1 - 12