Determination of tamsulosin in plasma of healthy Chinese male subjects by a novel and simple LC-MS/MS method and its application to pharmacokinetic studies

被引:0
作者
Zhong, Maolian [2 ]
Wang, Xing [2 ]
Xiong, Wenqiang [2 ]
Liu, Yan [2 ]
Wang, Xiaosong [1 ]
Yi, Xiaoyi [1 ]
Zhang, Hong [1 ,3 ]
机构
[1] Nanchang Univ, Jiangxi Canc Hosp, Clin Med Res Ctr, Nanchang 330029, Peoples R China
[2] Nanchang Univ, Sch Pharm, Nanchang 330006, Peoples R China
[3] Jiangxi Clin Res Ctr Canc, Nanchang 330029, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2023年 / 1229卷
关键词
Tamsulosin; LC-MS/MS; Protein precipitation method; Pharmacokinetics; Safety; BENIGN PROSTATIC HYPERPLASIA; CONTROLLED ABSORPTION SYSTEM; LOW-DOSE TAMSULOSIN; MODIFIED-RELEASE; MANAGEMENT; EFFICACY; ANTAGONISTS; SUBTYPES; SERUM;
D O I
10.1016/j.jchromb.2023.123901
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Tamsulosin, the first highly selective alpha 1-adrenoceptor antagonist, is widely used for urination disorders caused by benign prostatic hyperplasia (BPH). The pharmacokinetics and safety of 0.2 mg tamsulosin hydrochloride sustained-release capsules were evaluated in 60 healthy Chinese male subjects under fasting and fed conditions in this study. A simple, sensitive, and robust liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of tamsulosin in human plasma, which has been applied to pharmacokinetic study. The analyte and internal standard (tamsulosin-d5) were extracted by protein precipitation, and separated on a ZORBAX Eclipse XDB-C18 column (4.6 x 50 mm,1.8 mu m; Agilent Tech) using a gradient elution with mobile phases methanol and 5 mM ammonium acetate. The linear range was 0.05-15.0 ng/ mL. It showed good selectivity in normal, hyperlipidemic, and hemolyzed blank matrices. The CV (%) of intra-batch precision was <4.4% and the RE (%) of accuracy was in the range of -5.0%-6.7%; the CV (%) of inter-batch precision was <-5.8% and the RE (%) of accuracy was in the range of 1.2%-4.0%. The mean extraction recovery for the analyte was 102.1 +/- 3.75% and for the IS was 102.2 +/- 2.00%. Two formulations were considered bioequivalent under fasting and fed conditions, and the 90% confidence intervals for the geometric mean test/reference ratios were within the predetermined range of 80%-125%. A single oral dose of 0.2 mg tamsulosin hydrochloride sustained-release capsule was well-tolerated throughout the clinical trial, and no > Grade 1 adverse events (AEs) and serious AEs occurred during the trial.
引用
收藏
页数:9
相关论文
共 50 条
[41]   LC-MS/MS method for the determination of agomelatine in human plasma and its application to a pharmacokinetic study [J].
Wang, Xiaolin ;
Zhang, Dan ;
Liu, Man ;
Zhao, Hongna ;
Du, Aihua ;
Meng, Lingjie ;
Liu, Huichen .
BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (02) :218-222
[42]   Determination of terbinafine in healthy Chinese human plasma using a simple and fast LC-MS/MS method and its application to a bioequivalence study [J].
Yang, Can ;
Liu, Luyao ;
Sheng, Mang ;
Fu, Rong ;
Chen, Xiaodan ;
Yu, Zhongjian ;
Gao, Yuan ;
Zhang, Hong .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1191
[43]   A novel LC-MS/MS method for the determination of ziritaxestat in rat plasma and its pharmacokinetic study [J].
Chen, Jing ;
Guan, Zhenhua ;
Dong, Na ;
Li, Xueliang .
BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (08)
[44]   Sensitive LC-MS/MS method for quantification of rivaroxaban in plasma: Application to pharmacokinetic studies [J].
de Oliveira, Alexandre Cavenatti ;
Davanco, Marcelo Gomes ;
de Campos, Daniel Rossi ;
Godoy Sanches, Pedro Henrique ;
Goncalves Cirino, Joao Pedro ;
Carvalho, Patricia de Oliveira ;
Antonio, Marcia Aparecida ;
Coelho, Edvaldo Capobiango ;
Porcari, Andreia M. .
BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (09)
[45]   A Simplified, Accurate and Feasible LC-MS/MS Method for the Quantification of Dabigatran and its Application to a Pharmacokinetic Study in Healthy Chinese Subjects [J].
Wang, Yilin ;
Wang, Yan .
LATIN AMERICAN JOURNAL OF PHARMACY, 2023, 42 (02) :393-398
[46]   A simple and sensitive LC-MS/MS method for the determination of polyphyllin VII in rat plasma and its application to pharmacokinetic study [J].
Wang, Hao ;
Han, Han ;
Xu, Ying ;
Yang, Yishun .
BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (05)
[47]   Development of LC-MS/MS Method for Simultaneous Determination of Irinotecan and Its Main Metabolites in Rat Plasma, and Its Application in Pharmacokinetic Studies [J].
Wang, Nanxi ;
Zhu, Chaoran ;
Zhai, Xuejia ;
Zhang, Xinlin ;
Qin, Yanjie ;
Lu, Yongning .
CHROMATOGRAPHIA, 2017, 80 (01) :77-85
[48]   Development of a selective and sensitive LC-MS/MS method for the quantification of α-asarone in mouse plasma and its application to pharmacokinetic studies [J].
Ramalingam, Prakash ;
Ganesan, Palanivel ;
Choi, Dong-Kug ;
Ko, Young Tag .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 151 :284-290
[49]   Simultaneous determination of ipratropium and salbutamol in rat plasma by LC-MS/MS and its application to a pharmacokinetic study [J].
Wu, Jingwen ;
Ding, Cungang ;
Ge, Qinghua ;
Li, Zhou ;
Zhou, Zhen ;
Zhi, Xiaojin .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (30) :3475-3483
[50]   Development and Validation of a Sensitive LC-MS/MS Method for Determination of Betamethasone in Human Plasma. Application to a Pharmacokinetic Study of Healthy Mexican Subjects [J].
Patino-Rodriguez, Omar A. ;
Escobedo-Moratilla, Abraham ;
Maria Martinez-Medina, Rosa ;
Torres-Roque, Irma ;
Martinez-Delgado, Maricela ;
Perez-Urizar, Jose .
CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) :2-8