Understanding the ablation rate of Holmium:YAG and thulium fiber lasers. Perspectives from an in vitro study

被引:9
|
作者
Basulto-Martinez, Mario [1 ,2 ,3 ]
Proietti, Silvia [1 ,2 ]
Pavia, Maria Pia [1 ,2 ,4 ]
Yeow, Yuyi [2 ]
Eisner, Brian H. H. [5 ]
Giusti, Guido [1 ,2 ,6 ]
机构
[1] IRCCS San Raffaele Hosp, Dept Urol, Milan, Italy
[2] European Training Ctr Endourol, Milan, Italy
[3] Hosp Reg Alta Especial Peninsula Yucatan, Dept Urol, Merida, Mexico
[4] Marche Polytech Univ, Osped Riuniti Univ Hosp, Dept Urol, Ancona, Italy
[5] Massachusetts Gen Hosp, Dept Urol, Boston, MA USA
[6] Osped San Raffaele Srl, IRCCS, Via Olgettina 60, I-20132 Milan, Italy
关键词
Kidney stones; Urolithiasis; Lithotripsy; Holmium laser; Thulium fiber laser; LITHOTRIPSY;
D O I
10.1007/s00240-022-01402-6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
This study sought to analyze the ablation rates of Holmium:YAG (Ho:YAG) and thulium fiber laser (TFL) under different settings combinations. Lasering was carried out by a computed spiral pattern through a stepper motor bearing a laser fiber. BegoStones were placed inside a water container and lasered therein and the ablation rate was calculated. Different combinations were tested for similar to 12 Watts (W) for Ho:YAG and TFL lasers. Further 25 W combination for TFL were conducted testing higher frequencies. One-hundred-one experiments were conducted. Under similar to 12 W, the highest ablation rate for Ho:YAG was obtained with 40 Hz/0.3 J, and Virtual Basket (TM) (VB) emission mode [114.35 (88.30 - 126.40) mg/min] whereas for TFL, using 40 Hz/0.3 J, and long pulse [143.40 (137.40 - 146) mg/min]. A matched-comparison for 12 Hz/1 J settings showed that TFL outperformed Ho:YAG using medium pulse [63.30 (55.30 - 81.30) vs 132.00 (115.70 - 228.60) mg/min, p=0.016] and long pulse [62.90 (51.60 - 78.90) vs 134.70 (110.60 - 149.30) mg/min, p=0.016]. In the 40 Hz/0.3 J settings, TFL outperformed Ho:YAG (p=0.034). Nonetheless, Ho:YAG with VB's ablation rate increased [114.35 (88.30 - 126.40)], being comparable to that of TFL with medium pulse [127.5 (88.90 - 141.70)] (p=0.400). In TFL 25 W experiments, the ablation rate of 500 Hz / 0.05 J, was higher than those of 1000 Hz / 0.025 J (p=0.049). TFL ablation rate is higher than that of Ho:YAG. Moreover, the Virtual Basket (TM) emission mode, increased Ho:YAG ablation rates, resulting reaching similar to that of TFL in certain modalities.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] High power holmium:YAG versus thulium fiber laser treatment of kidney stones in dusting mode: ablation rate and fragment size studies
    Hardy, Luke A.
    Vinnichenko, Viktoriya
    Fried, Nathaniel M.
    LASERS IN SURGERY AND MEDICINE, 2019, 51 (06) : 522 - 530
  • [22] Effect of temporal pulse shape on urinary stone phantom retropulsion rate and ablation efficiency using holmium:YAG and super-pulse thulium fibre lasers
    Ventimiglia, Eugenio
    Doizi, Steeve
    Kovalenko, Anastasiya
    Andreeva, Viktoria
    Traxer, Olivier
    BJU INTERNATIONAL, 2020, 126 (01) : 159 - 167
  • [23] Is "Kidney Stone Calculator" efficient in predicting ureteroscopic lithotripsy duration? A holmium:YAG and thulium fiber lasers comparative analysis
    Chicaud, Marie
    Kutchukian, Stessy
    Doizi, Steeve
    Audenet, Francois
    Berthe, Laurent
    Yonneau, Laurent
    Lebret, Thierry
    Timsit, Marc-Olivier
    Mejean, Arnaud
    Candela, Luigi
    Solano, Catalina
    Corrales, Mariela
    Duquesne, Igor
    Descazeaud, Aurelien
    Traxer, Olivier
    Panthier, Frederic
    WORLD JOURNAL OF UROLOGY, 2024, 42 (01)
  • [24] Holmium:YAG and Neodymium:YAG lasers used in orthopaedic surgery -: a critical consideration of indications in an in vitro study
    Anders, JO
    Pietsch, S
    Staupendahl, G
    BIOMEDIZINISCHE TECHNIK, 1999, 44 (04): : 83 - 86
  • [25] ALTERNATIVE LASERS FOR ENDOSCOPIC SURGERY - COMPARISON OF PULSED THULIUM-HOLMIUM-CHROMIUM - YAG WITH CONTINUOUS-WAVE NEODYMIUM - YAG LASER FOR ABLATION OF COLONIC MUCOSA
    BASS, LS
    OZ, MC
    TROKEL, SL
    TREAT, MR
    LASERS IN SURGERY AND MEDICINE, 1991, 11 (06) : 545 - 549
  • [26] Temperature profiles during ureteroscopy with thulium fiber laser and holmium:YAG laser: Findings from a pre-clinical study
    Aesoy, M. S.
    Juliebo-Jones, P.
    Beisland, C.
    Ulvik, O.
    SCANDINAVIAN JOURNAL OF UROLOGY, 2022, 56 (04) : 313 - 319
  • [27] Renal temperatures and thermal profiles during ureteroscopy with Thulium Fiber Laser and Holmium YAG laser: Findings from a preclinical study
    Asoy, M. S.
    Juliebo-Jones, P.
    Beisland, C.
    Ulvik, O.
    EUROPEAN UROLOGY, 2022, 81 : S1739 - S1740
  • [28] Ablation Efficiency of a Novel Thulium Fiber Laser: An In Vitro Study on Laser Setting and Fiber Usage
    Liu, Min
    Peng, Yonghan
    Wang, Zeyu
    Li, Ling
    Ming, Shaoxiong
    Fang, Ziyu
    Dong, Hao
    Li, Rui
    Gao, Xiaofeng
    JOURNAL OF ENDOUROLOGY, 2021, 35 (08) : 1211 - 1216
  • [29] Holmium:YAG (λ=2120 nm) vs. Thulium Fiber Laser (λ=1908 nm) Ablation of Kidney Stones: Thresholds, Rates, and Retropulsion
    Blackmon, Richard L.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883
  • [30] IN VITRO COMPARISON OF ABLATION RATES BETWEEN SUPERPULSED THULIUM FIBER LASER AND HO:YAG LASER FOR ENDOCORPOREAL LITHOTRIPSY
    Panthier, Frederic
    Doizi, Steeve
    Berthe, Laurent
    Traxer, Olivier
    JOURNAL OF UROLOGY, 2020, 203 : E83 - E83