Simple analytical considerations on a thermal-flow operating parameters of a heat storage tank

被引:0
作者
Dolna, Oktawia [1 ]
Wisniewska, Weronika [2 ]
机构
[1] Polish Acad Sci, Ctr Heat & Power Engn, Heat Transfer Dept, Inst Fluid Flow Machinery, Fiszera 14 St, PL-80231 Gdansk, Poland
[2] Polish Acad Sci, Inst Fluid Flow Machinery, Ctr Heat & Power Engn, Turbine Dept, Fiszera 14 St, PL-80231 Gdansk, Poland
关键词
Heat storage tank; Lumped capacitance method; Dimensionless numbers; ENERGY STORAGE; STRATIFICATION; PERFORMANCE; EFFICIENCY;
D O I
10.1007/s40095-022-00516-2
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A heat storage tank (HST), described in this paper, may be applied to numerous systems used for thermal energy generation and storage. Working principle and heat-flow processes of the HST remain the same and are independent of the systems in which the HST is being used. This paper presents a thermal-flow analysis of a heat storage tank (HST) operating in an air compressor heat pump (ACHP) and a dry cooler (DC) combined cycle. The HST is operated under transient conditions for four different ACHP steady states. The HST was analysed using lumped capacitance method. The heating power of a single coil varied from 2.2 to 3.2 kW. 50% increase in mass flow rate of heating water in the coils increased the HST water mean temperature by 5.6 degrees C. A differential equation for the HST water temperature variation was solved analytically and it was presented with the use of dimensionless numbers. The presented solution is of a general form. An important parameter such as number of the coils may be varied easily. Additionally, a Mathcad computational program was proposed for the estimation of HST-ACHP-DC system thermodynamic and thermal-flow parameters. System dynamics was studied using MATLAB/Simulink. An optimal operating parameters of the HST were found and are presented in the paper. The aforementioned parameters are as follows: mass flow rates of heating and cooling media in all three coils, mass flow rate of freshwater supplying the HST, number of loops in coils and resulting heat transfer area, diameter of the loops of the coils, diameter of the coils, time after which water in the HST reaches a steady value, time period within which the HST may fulfil demand for central heating and domestic hot water (DHW) preparation without being charged simultaneously. The presented analytical model was validated based on the available data in the field literature and a high compliance was reached. For this purpose theoretical model results were compared to results of HST computational fluid dynamics (CFD) simulations. The temperature calculated using the presented model differed from the one obtained by the CFD analysis by 2.96 K.
引用
收藏
页码:387 / 403
页数:17
相关论文
共 50 条
  • [32] Thermal stratification in a solar hot water storage tank with mantle heat exchanger
    Li, Qiong
    Huang, Xiaoqiao
    Tai, Yonghang
    Gao, Wenfeng
    Wenxian, L.
    Liu, Wuming
    RENEWABLE ENERGY, 2021, 173 (173) : 1 - 11
  • [33] SIMPLIFIED MODELING OF THERMAL STORAGE TANK FOR DISTRIBUTED ENERGY HEAT RECOVERY APPLICATIONS
    Rahman, Aowabin
    Fumo, Nelson
    Smith, Amanda D.
    PROCEEDINGS OF ASME 9TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2015, VOL 2, 2016,
  • [34] Thermal analytical model of latent thermal storage with heat pipe heat exchanger for concentrated solar power
    Jung, Eui Guk
    Boo, Joon Hong
    SOLAR ENERGY, 2014, 102 : 318 - 332
  • [35] Thermal storage performance of a horizontal eccentric distance spiral shell-tube heat storage tank
    Mao, Qianjun
    Zhao, Yuan
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [36] Study on the influence of tank structure and fin configuration on heat transfer performance of phase change thermal storage system
    Mao, Qianjun
    Li, Ying
    Li, Guiqiang
    Badiei, Ali
    ENERGY, 2021, 235
  • [37] Analytical solution of heat transfer in a shell-and-tube latent thermal energy storage system
    Bechiri, Mohammed
    Mansouri, Kacem
    RENEWABLE ENERGY, 2015, 74 : 825 - 838
  • [38] Numerical Studies on the Performance of the PCM Mesh-Finned Heat Sink Base on Thermal-Flow Multiphysics Coupling Simulation
    Liu, Jiefeng
    Yu, Shangxin
    Yang, Shichang
    Zhang, Yiyi
    Fan, Xianhao
    Gao, Bing
    ENERGIES, 2020, 13 (18)
  • [39] EXPERIMENTAL STUDY ON THERMAL STORAGE PERFORMANCE OF CYLINDRICALLY ENCAPSULATED PCM IN A CYLINDRICAL STORAGE TANK WITH AXIAL FLOW
    Wickramaratne, Chatura
    Moloney, Francesca
    Pirasaci, Tolga
    Kamal, Rajeev
    Goswami, D. Y.
    Stefanakos, Elias
    Dhau, Jaspreet
    PROCEEDINGS OF THE ASME POWER CONFERENCE, 2016, 2016,
  • [40] Thermal performance of a solar-assisted heat pump drying system with thermal energy storage tank and heat recovery unit
    Ismaeel, Hatem Hasan
    Yumrutas, Recep
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (05) : 3426 - 3445