Comparison of Digital versus Analog 68Ga-PSMA-11 PET/CT Performance in Hormone-Sensitive Prostate Cancer Patients with Early Biochemical Recurrence or Persistence after Radical Treatment

被引:2
作者
Rovera, Guido [1 ]
Grimaldi, Serena [2 ]
Dall'Armellina, Sara [2 ]
Zotta, Michela [2 ]
Finessi, Monica [2 ]
Passera, Roberto [2 ]
Deandreis, Desiree [3 ]
机构
[1] Univ Turin, Dept Med Sci, Nucl Med Div, I-10126 Turin, Italy
[2] Univ Turin, Dept Med Sci, Nucl Med Div, AOU Citta Salute & Sci Torino, I-10126 Turin, Italy
[3] Gustave Roussy, Nucl Med Div, F-94805 Villejuif, France
关键词
PET/CT; digital PET/CT; Ga-68-PSMA-11; prostate cancer; biochemical recurrence; METASTASIS-DIRECTED THERAPY; RECONSTRUCTION; MANAGEMENT; OUTCOMES; DISEASE; IMPACT;
D O I
10.3390/diagnostics13233535
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to investigate whether the favorable characteristics of novel digital PET/CT (dPET) scanners compared to analog systems (aPET) could translate into an improved disease localization in prostate cancer (PCa) patients with early biochemical recurrence/persistence (BCR/BCP). A retrospective analysis was conducted on 440 consecutive analog (n = 311) or digital (n = 129) Ga-68-PSMA-11 PET/CT scans performed in hormone-sensitive ADT-free PCa patients with early-BCR/BCP (PSA at PET <= 2.0 ng/mL), previously treated with radical intent (radical-prostatectomy/radiotherapy). dPET showed a higher positivity rate compared to aPET (48.8% [63/129] vs. 37.3% [116/311], p = 0.03), despite the slightly lower median PSA value of the dPET cohort (0.33 [IQR: 0.26-0.61] vs. 0.55 [IQR: 0.40-0.85] ng/mL, p < 0.01). dPET detection rate was higher in both PSA ranges 0.2-0.5 ng/mL (39.0% [32/82] vs. 25.2% [34/135], p = 0.03) and 0.5-1.0 ng/mL (63.2% [24/38] vs. 40.8% [53/130], p = 0.02), but not for PSA >= 1.0 ng/mL. dPET detected a higher per patient median number of pathologic findings (PSMA-RADS >= 3) and multi-metastatic cases (>3 lesions) among N1/M1-positive scans (21.7% [10/46] vs. 8.6% [9/105], p = 0.03). Moreover, the proportion of uncertain findings among pathological lesions was significantly lower for dPET than aPET (24.4% [39/160] vs. 38.5% [60/156], p = 0.008). Overall, Ga-68-PSMA-11 dPET showed a better performance compared to aPET, resulting in a higher scan-positivity rate, a higher number of detected pathological lesions, and a lower rate of uncertain findings.
引用
收藏
页数:14
相关论文
共 55 条
[1]   Diagnostic performance of 68Ga-PSMA-11 (HBED-CC) PET/CT in patients with recurrent prostate cancer: evaluation in 1007 patients [J].
Afshar-Oromieh, Ali ;
Holland-Letz, Tim ;
Giesel, Frederik L. ;
Kratochwil, Clemens ;
Mier, Walter ;
Haufe, Sabine ;
Debus, Nils ;
Eder, Matthias ;
Eisenhut, Michael ;
Schaefer, Martin ;
Neels, Oliver ;
Hohenfellner, Markus ;
Kopka, Klaus ;
Kauczor, Hans-Ulrich ;
Debus, Juergen ;
Haberkorn, Uwe .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 (08) :1258-1268
[2]   Feasibility of late acquisition [68Ga]Ga-PSMA-11 PET/CT using a long axial field-of-view PET/CT scanner for the diagnosis of recurrent prostate cancer-first clinical experiences [J].
Alberts, Ian ;
Prenosil, George ;
Mingels, Clemens ;
Bohn, Karl Peter ;
Viscione, Marco ;
Sari, Hasan ;
Rominger, Axel ;
Afshar-Oromieh, Ali .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (13) :4456-4462
[3]   The influence of digital PET/CT on diagnostic certainty and interrater reliability in [68Ga]Ga-PSMA-11 PET/CT for recurrent prostate cancer [J].
Alberts, Ian ;
Huenermund, Jan-Niklas ;
Sachpekidis, Christos ;
Mingels, Clemens ;
Fech, Viktor ;
Bohn, Karl Peter ;
Rominger, Axel ;
Afshar-Oromieh, Ali .
EUROPEAN RADIOLOGY, 2021, 31 (10) :8030-8039
[4]   Digital versus analogue PET in [68Ga]Ga-PSMA-11 PET/CT for recurrent prostate cancer: a matched-pair comparison [J].
Alberts, Ian ;
Prenosil, George ;
Sachpekidis, Christos ;
Weitzel, Thilo ;
Shi, Kuangyu ;
Rominger, Axel ;
Afshar-Oromieh, Ali .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (03) :614-623
[5]   A Systematic Review of the Role of Imaging before Salvage Radiotherapy for Post-prostatectomy Biochemical Recurrence [J].
Beresford, M. J. ;
Gillatt, D. ;
Benson, R. J. ;
Ajithkumar, T. .
CLINICAL ONCOLOGY, 2010, 22 (01) :46-55
[6]   PSMA-PET Guided Treatment in Prostate Cancer Patients with Oligorecurrent Progression after Previous Salvage Treatment [J].
Bianchi, Lorenzo ;
Ceci, Francesco ;
Balestrazzi, Eleonora ;
Costa, Francesco ;
Droghetti, Matteo ;
Piazza, Pietro ;
Pissavini, Alessandro ;
Presutti, Massimiliano ;
Farolfi, Andrea ;
Mei, Riccardo ;
Castellucci, Paolo ;
Gandaglia, Giorgio ;
Larcher, Alessandro ;
Robesti, Daniele ;
Mottrie, Alexandre ;
Briganti, Alberto ;
Morganti, Alessio Giuseppe ;
Fanti, Stefano ;
Montorsi, Francesco ;
Schiavina, Riccardo ;
Brunocilla, Eugenio .
CANCERS, 2023, 15 (07)
[7]   Detection of lymph node metastases in patients with prostate cancer: Comparing conventional and digital [18F]-fluorocholine PET-CT using histopathology as a reference [J].
Bjoersdorff, Mimmi ;
Puterman, Christopher ;
Oddstig, Jenny ;
Amidi, Jennifer ;
Zackrisson, Sophia ;
Kjolhede, Henrik ;
Bjartell, Anders ;
Wollmer, Per ;
Tragardh, Elin .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2022, 42 (06) :381-388
[8]   18F-fluciclovine PET-CT and 68Ga-PSMA-11 PET-CT in patients with early biochemical recurrence after prostatectomy: a prospective, single-centre, single-arm, comparative imaging trial [J].
Calais, Jeremie ;
Ceci, Francesco ;
Eiber, Matthias ;
Hope, Thomas A. ;
Hofman, Michael S. ;
Rischpler, Christoph ;
Bach-Gansmo, Tore ;
Nanni, Cristina ;
Savir-Baruch, Bital ;
Elashoff, David ;
Grogan, Tristan ;
Dahlbom, Magnus ;
Slavik, Roger ;
Gartmann, Jeannine ;
Nguyen, Kathleen ;
Lok, Vincent ;
Jadvar, Hossein ;
Kishan, Amar U. ;
Rettig, Matthew B. ;
Reiter, Robert E. ;
Fendler, Wolfgang P. ;
Czernin, Johannes .
LANCET ONCOLOGY, 2019, 20 (09) :1286-1294
[9]   Impact of 68Ga-PSMA-11 PET/CT on the Management of Prostate Cancer Patients with Biochemical Recurrence [J].
Calais, Jeremie ;
Fendler, Wolfgang P. ;
Eiber, Matthias ;
Gartmann, Jeannine ;
Chu, Fang-I ;
Nickols, Nicholas G. ;
Reiter, Robert E. ;
Rettig, Matthew B. ;
Marks, Leonard S. ;
Ahlering, Thomas E. ;
Huynh, Linda M. ;
Slavik, Roger ;
Gupta, Pawan ;
Quon, Andrew ;
Allen-Auerbach, Martin S. ;
Czernin, Johannes ;
Herrmann, Ken .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (03) :434-441
[10]   From a PMT-based to a SiPM-based PET system: a study to define matched acquisition/reconstruction parameters and NEMA performance of the Biograph Vision 450 [J].
Carlier, Thomas ;
Ferrer, Ludovic ;
Conti, Maurizio ;
Bodet-Milin, Caroline ;
Rousseau, Caroline ;
Bercier, Yanic ;
Bendriem, Bernard ;
Kraeber-Bodere, Francoise .
EJNMMI PHYSICS, 2020, 7 (01)