Anterior Referencing versus Posterior Referencing in Primary Total Knee Arthroplasty: A Meta-Analysis of Randomized Controlled Trials

被引:4
作者
Familiari, Filippo [1 ,2 ]
Mercurio, Michele [1 ]
Napoleone, Francesco [1 ]
Galasso, Olimpio [1 ,2 ]
Giuzio, Ermes [3 ]
Simonetta, Roberto [3 ]
Palco, Michelangelo [3 ]
Dephillipo, Nicholas N. [4 ]
Gasparini, Giorgio [1 ,2 ]
机构
[1] Magna Graecia Univ Catanzaro, Dept Orthopaed & Trauma Surg, I-88100 Catanzaro, Italy
[2] Magna Graecia Univ Catanzaro, Res Ctr Musculoskeletal Hlth, MusculoSkeletalHlth UMG, I-88100 Catanzaro, Italy
[3] Villa Sole Clin, Div Orthopaed & Trauma Surg, I-88100 Catanzaro, Italy
[4] Univ Penn, Dept Orthopaed Surg, Philadelphia, PA 19104 USA
关键词
systematic review; meta-analysis; anterior referencing; randomized controlled trials; posterior referencing; total knee arthroplasty; clinical outcome; radiographic outcome; CONDYLAR OFFSET; TIBIAL SLOPE; FLEXION; REPLACEMENT; KINEMATICS; RISK;
D O I
10.3390/jcm12237453
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: The purpose of this study was to perform a systematic review and meta-analysis of studies comparing clinical and radiographic outcomes between anterior referencing (AR) and posterior referencing (PR) systems in total knee arthroplasty (TKA). (2) Methods: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. PubMed, MEDLINE, Scopus, and Cochrane Central databases were searched in August 2022. Data extracted for quantitative analysis included the Knee Society Score (KSS), the Western Ontario and McMaster University (WOMAC) index, knee ROM, posterior condylar offset (PCO), and the posterior condylar offset ratio (PCOR). The methodological quality of the included studies was assessed using the Modified Newcastle-Ottawa Quality Assessment. Randomized controlled trials were assessed with version 2 of the risk of bias tool (RoB2), recommended by the Cochrane Collaboration. (3) Results: For the meta-analysis, five comparative studies met the eligibility criteria. There were 584 patients in all, 294 of whom had AR TKA and 290 of whom had PR TKA. Three studies with 181 and 179 cases in the AR and PR groups, respectively, had reported preoperative KSS. A statistically significant difference was found favoring the PR group. (p = 0.01). The same cases' postoperative range of motion was documented, and a statistically significant difference was discovered in favor of the AR group. Postoperative PCO was described in four studies in 243 and 241 cases in the AR and PR TKA groups, respectively, and a statistically significant difference was found with a higher postoperative PCO in the PR group (p = 0.003). Postoperative PCOR was calculated in two studies in the same cases in the AR and PR TKA groups and a statistically significant difference was found with a higher postoperative PCOR in the PR group (p = 0.002). (4) Conclusion: Anterior referencing for TKA may result in improved knee ROM postoperatively, while posterior referencing may produce larger PCO and PCOR on postoperative imaging. However, no significant differences were noted in clinical outcomes between the AR and PR groups at final follow-up.
引用
收藏
页数:11
相关论文
共 34 条
[1]   The posterior condylar offset ratio and femoral anatomy in anterior versus posterior referencing total knee arthroplasty [J].
Almeida, P. H. ;
Vilaca, A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (06) :687-691
[2]   Evaluation of the Accuracy and Precision of a Next Generation Computer-Assisted Surgical System [J].
Angibaud, Laurent D. ;
Dai, Yifei ;
Liebelt, Ralph A. ;
Gao, Bo ;
Gulbransen, Scott W. ;
Silver, Xeve S. .
CLINICS IN ORTHOPEDIC SURGERY, 2015, 7 (02) :225-233
[3]   Posterior condylar offset and flexion in posterior cruciate-retaining and posterior stabilized TKA [J].
Arabori, Motoya ;
Matsui, Nobuzo ;
Kuroda, Ryosuke ;
Mizuno, Kiyonori ;
Doita, Minoru ;
Kurosaka, Masahiro ;
Yoshiya, Shinichi .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2008, 13 (01) :46-50
[4]   The influence of tibial slope on maximal flexion after total knee arthroplasty [J].
Bellemans, J ;
Robijns, F ;
Duerinckx, J ;
Banks, S ;
Vandenneucker, H .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) :193-196
[5]   Effects of patellofemoral overstuffing on knee flexion and patellar kinematics following total knee arthroplasty: a cadaveric study [J].
Bracey, Daniel N. ;
Brown, Matthew L. ;
Beard, Hoyt R. ;
Mannava, Sandeep ;
Nazir, Omar F. ;
Seyler, Thorsten M. ;
Lang, J. E. .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) :1715-1722
[6]   Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplasty [J].
Catani, F ;
Fantozzi, S ;
Ensini, A ;
Leardini, A ;
Moschella, D ;
Giannini, S .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (04) :581-587
[7]   Posterior condylar offset changes and its effect on clinical outcomes after posterior-substituting, fixed-bearing total knee arthroplasty: anterior versus posterior referencing [J].
Chang, Moon Jong ;
Kang, Seung-Baik ;
Chang, Chong Bum ;
Han, Do Hwan ;
Park, Hyung Jun ;
Hwang, Keummin ;
Park, Jisu ;
Hwang, Il-Ung ;
Lee, Seung Ah ;
Oh, Sohee .
KNEE SURGERY & RELATED RESEARCH, 2020, 32 (01)
[8]   FEMORAL COMPONENT SIZING DURING TOTAL KNEE ARTHROPLASTY Anterior Versus Posterior Referencing [J].
Charette, Ryan S. ;
Sheth, Neil P. ;
Boettner, Friedrich ;
Scuderi, Giles R. ;
Melnic, Christopher M. .
JBJS REVIEWS, 2018, 6 (01)
[9]   Does Accurate Anatomical Alignment Result in Better Function and Quality of Life? Comparing Conventional and Computer-Assisted Total Knee Arthroplasty [J].
Choong, Peter F. ;
Dowsey, Michelle M. ;
Stoney, James D. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :560-569
[10]  
Chun Keun Churl, 2013, Knee Surg Relat Res, V25, P93, DOI 10.5792/ksrr.2013.25.3.93