Cooling Technologies for Internet Data Center in China: Principle, Energy Efficiency, and Applications

被引:6
|
作者
Huang, Xiaofei [1 ,2 ]
Yan, Junwei [1 ,2 ]
Zhou, Xuan [1 ,2 ]
Wu, Yixin [1 ,2 ]
Hu, Shichen [1 ]
机构
[1] South China Univ Technol, Sch Mech & Automot Engn, 381, Wushan Rd, Guangzhou 510640, Peoples R China
[2] Guangdong Artificial Intelligence & Digital Econ L, 70, Yuean Rd, Guangzhou 510640, Peoples R China
关键词
internet data center; PUE; energy efficiency; cooling technologies; energy saving rate; AIR-SIDE ECONOMIZERS; COOLED DATA CENTERS; BASE STATIONS TBSS; HEAT-PIPE SYSTEM; THERMAL MANAGEMENT; FLOW; PERFORMANCE; CHALLENGES; LEAKAGE; FLUID;
D O I
10.3390/en16207158
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The highlighted energy consumption of Internet data center (IDC) in China has become a pressing issue with the implementation of the Chinese dual carbon strategic goal. This paper provides a comprehensive review of cooling technologies for IDC, including air cooling, free cooling, liquid cooling, thermal energy storage cooling and building envelope. Firstly, the environmental requirements for the computer room and the main energy consumption items for IDC are analyzed. The evaluation indicators and government policies for promoting green IDC are also summarized. Next, the traditional cooling technology is compared to four new cooling technologies to find effective methods to maximize energy efficiency in IDC. The results show that traditional cooling consumes a significant amount of energy and has low energy efficiency. The application of free cooling can greatly improve the energy efficiency of IDC, but its actual implementation is highly dependent on geographical and climatic conditions. Liquid cooling, on the other hand, has higher energy efficiency and lower PUE compared to other cooling technologies, especially for high heat density servers. However, it is not yet mature and its engineering application is not widespread. In addition, thermal energy storage (TES) based cooling offers higher energy efficiency but must be coupled with other cooling technologies. Energy savings can also be achieved through building envelope improvements. Considering the investment and recovery period for IDC, it is essential to seek efficient cooling solutions that are suitable for IDC and take into account factors such as IDC scale, climate conditions, maintenance requirements, etc. This paper serves as a reference for the construction and development of green IDC in China.
引用
收藏
页数:31
相关论文
共 50 条
  • [41] The effect of data center temperature on energy efficiency
    Patterson, Michael K.
    2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, : 1167 - 1174
  • [42] Energy efficiency dependency analysis for a data center
    Dumitru, I. (iulia.dumitru@aii.pub.ro), 1600, Springer Verlag (187 AISC):
  • [43] Energy Efficiency Measurements of Data Center Systems
    Horalek, J.
    Matyska, J.
    Sobeslav, V.
    Suba, P.
    2014 ELEKTRO, 2014, : 41 - 45
  • [44] PASSIVE COOLING POTENTIAL OF TWO DIFFERENT PCM COOLING CEILINGS IN THE ENERGY EFFICIENCY CENTER
    Weinlaeder, Helmut
    Klinker, Felix
    Yasin, Modar
    11TH IIR CONFERENCE ON PHASE CHANGE MATERIALS AND SLURRIES FOR REFRIGERATION AND AIR CONDITIONING, 2016, : 77 - 85
  • [45] Data center cooling efficiency improvement through localized and optimized cooling resources delivery
    Zhou, R. (Rongliang.Zhou@hp.com), 1600, Hewlett Packard Laboratories
  • [46] DATA CENTER COOLING EFFICIENCY IMPROVEMENT THROUGH LOCALIZED AND OPTIMIZED COOLING RESOURCES DELIVERY
    Zhou, Rongliang
    Bash, Cullen
    Wang, Zhikui
    McReynolds, Alan
    Christian, Thomas
    Cader, Tahir
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 1789 - 1796
  • [47] Review on Cooling System Energy Consumption in Internet Data Centers
    Amoabeng, Kofi Owura
    Choi, Jong Min
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
  • [48] Escope: An Energy Efficiency Simulator for Internet Data Centers
    Liu, Jun
    Yan, Longchuan
    Yan, Chengxu
    Qiu, Yeliang
    Jiang, Congfeng
    Li, Yang
    Li, Yan
    Cerin, Christophe
    ENERGIES, 2023, 16 (07)
  • [49] Benchmarking Big Data Technologies for Energy Procurement Efficiency
    Fritz, Manuel
    Albrecht, Simon
    Ziekow, Holger
    Strueker, Jens
    AMCIS 2017 PROCEEDINGS, 2017,
  • [50] Optimal Energy Management of Internet Data Center With Distributed Energy Resources
    Zhou, Kaile
    Fei, Zhineng
    Lu, Xinhui
    IEEE TRANSACTIONS ON CLOUD COMPUTING, 2023, 11 (03) : 2285 - 2295