Cooling Technologies for Internet Data Center in China: Principle, Energy Efficiency, and Applications

被引:6
|
作者
Huang, Xiaofei [1 ,2 ]
Yan, Junwei [1 ,2 ]
Zhou, Xuan [1 ,2 ]
Wu, Yixin [1 ,2 ]
Hu, Shichen [1 ]
机构
[1] South China Univ Technol, Sch Mech & Automot Engn, 381, Wushan Rd, Guangzhou 510640, Peoples R China
[2] Guangdong Artificial Intelligence & Digital Econ L, 70, Yuean Rd, Guangzhou 510640, Peoples R China
关键词
internet data center; PUE; energy efficiency; cooling technologies; energy saving rate; AIR-SIDE ECONOMIZERS; COOLED DATA CENTERS; BASE STATIONS TBSS; HEAT-PIPE SYSTEM; THERMAL MANAGEMENT; FLOW; PERFORMANCE; CHALLENGES; LEAKAGE; FLUID;
D O I
10.3390/en16207158
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The highlighted energy consumption of Internet data center (IDC) in China has become a pressing issue with the implementation of the Chinese dual carbon strategic goal. This paper provides a comprehensive review of cooling technologies for IDC, including air cooling, free cooling, liquid cooling, thermal energy storage cooling and building envelope. Firstly, the environmental requirements for the computer room and the main energy consumption items for IDC are analyzed. The evaluation indicators and government policies for promoting green IDC are also summarized. Next, the traditional cooling technology is compared to four new cooling technologies to find effective methods to maximize energy efficiency in IDC. The results show that traditional cooling consumes a significant amount of energy and has low energy efficiency. The application of free cooling can greatly improve the energy efficiency of IDC, but its actual implementation is highly dependent on geographical and climatic conditions. Liquid cooling, on the other hand, has higher energy efficiency and lower PUE compared to other cooling technologies, especially for high heat density servers. However, it is not yet mature and its engineering application is not widespread. In addition, thermal energy storage (TES) based cooling offers higher energy efficiency but must be coupled with other cooling technologies. Energy savings can also be achieved through building envelope improvements. Considering the investment and recovery period for IDC, it is essential to seek efficient cooling solutions that are suitable for IDC and take into account factors such as IDC scale, climate conditions, maintenance requirements, etc. This paper serves as a reference for the construction and development of green IDC in China.
引用
收藏
页数:31
相关论文
共 50 条
  • [31] Increase of the Efficiency of the System of Cooling of Data Processing Center Servers
    Starkova, L. G.
    Farkhutdinova, E. R.
    2ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING (ICIE-2016), 2016, 150 : 2345 - 2351
  • [32] DATA CENTER COOLING EFFICIENCY WITH SIMULATION-BASED OPTIMIZATION
    Billet, Laurent M.
    Healey, Christopher M.
    VanGilder, James W.
    Pardey, Zachary M.
    INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2015, VOL 1, 2015,
  • [33] Current Status and Future Trends in Data-Center Cooling Technologies
    Li, Zhen
    Kandlikar, Satish G.
    HEAT TRANSFER ENGINEERING, 2015, 36 (06) : 523 - 538
  • [34] Data Center Energy Efficiency: Improving Energy Efficiency in Data Centers Beyond Technology Scaling
    Chong, Frederic T.
    Saleh, Adel A. M.
    Heck, Martijn J. R.
    Ranganathan, Parthasarathy
    Wassel, Hassan M. G.
    IEEE DESIGN & TEST, 2014, 31 (01) : 93 - 104
  • [35] Energy efficiency optimization of an integrated heat pipe cooling system in data center based on genetic algorithm
    He, Zhiguang
    Xi, Haonan
    Ding, Tao
    Wang, Jianmin
    Li, Zhen
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [36] Optimal setting parameters of cooling system under different climate zones for data center energy efficiency
    Liu, Jing
    Su, Lin
    Dong, Kaijun
    Sun, Qin
    Shao, Zhenhua
    Huang, Gongsheng
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (07) : 10086 - 10099
  • [37] Improvement of Energy Efficiency and Control Performance of Cooling System Fan Applied to Industry 4.0 Data Center
    Ko, Jae-Sub
    Huh, Jun-Ho
    Kim, Jong-Chan
    ELECTRONICS, 2019, 8 (05):
  • [38] THE (NON)DISCLOSURE OF ENERGY EFFICIENCY: THE CASE OF COOLING TECHNOLOGIES ACROSS AFRICA
    Aja, Pille-riin
    Giraudet, LOUIS-GAeTAN
    Houde, Sebastien
    CLIMATE CHANGE ECONOMICS, 2024,
  • [39] On Energy Efficiency for Enterprise and Data Center Networks
    Mahadevan, Priya
    Banerjee, Sujata
    Sharma, Puneet
    Shah, Amip
    Ranganathan, Parthasarathy
    IEEE COMMUNICATIONS MAGAZINE, 2011, 49 (08) : 94 - 100
  • [40] Data center workload placement for energy efficiency
    Bash, Cullen
    Forman, George
    IPACK 2007: PROCEEDINGS OF THE ASME INTERPACK CONFERENCE 2007, VOL 1, 2007, : 733 - 741