Nuclear Overhauser enhancement imaging at-1.6 ppm in rat brain at 4.7T

被引:5
作者
Viswanathan, Malvika [1 ,2 ]
Kurmi, Yashwant [1 ,3 ]
Zu, Zhongliang [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN USA
[2] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN USA
[3] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN USA
基金
美国国家卫生研究院;
关键词
CEST; NOE; tumor; EXCHANGE SATURATION-TRANSFER; PROTON-TRANSFER APT; IN-VIVO; MAGNETIZATION-TRANSFER; TRANSFER CEST; MOUSE MODEL; AMIDE; NOE; RELAXATION; SIGNAL;
D O I
10.1002/mrm.29896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A new nuclear Overhauser enhancement (NOE)-mediated saturation transfer signal at around -1.6 ppm, termed NOE(-1.6), has been reported at high fields of 7T and 9.4T previously. This study aims to validate the presence of this signal at a relatively low field of 4.7T and evaluate its variations in different brain regions and tumors.Methods: Rats were injected with monocrystalline iron oxide nanoparticles to reduce the NOE(-1.6) signal. CEST signals were measured using different saturation powers before and after injection to assess the presence of this signal. Multiple-pool Lorentzian fits, with/without inclusion of the NOE(-1.6) pool, were performed on CEST Z-spectra obtained from healthy rat brains and rats with 9L tumors. These fits aimed to further validate the presence of the NOE(-1.6) signal and quantify its amplitude.Results: The NOE(-1.6) signal exhibited a dramatic change following the injection of monocrystalline iron oxide nanoparticles, confirming its presence at 4.7T. The NOE(-1.6) signal reached its peak at a saturation power of similar to 0.75 mu T, indicating an optimized power level. The multiple-pool Lorentzian fit without the NOE(-1.6) pool showed higher residuals around -1.6 ppm compared to the fit with this pool, further supporting the presence of this signal. The NOE(-1.6) signal did not exhibit significant variation in the corpus callosum and caudate putamen regions, but it showed a significant decrease in tumors, which aligns with previous findings at 9.4T.Conclusion: This study successfully demonstrated the presence of the NOE(-1.6) signal at 4.7T, which provides valuable insights into its potential applications at lower field strengths.
引用
收藏
页码:615 / 629
页数:15
相关论文
共 50 条
  • [21] Nuclear Overhauser Enhancement Imaging of Glioblastoma at 7 Tesla: Region Specific Correlation with Apparent Diffusion Coefficient and Histology
    Paech, Daniel
    Burth, Sina
    Windschuh, Johannes
    Meissner, Jan-Eric
    Zaiss, Moritz
    Eidel, Oliver
    Kickingereder, Philipp
    Nowosielski, Martha
    Wiestler, Benedikt
    Sahm, Felix
    Floca, Ralf Omar
    Neumann, Jan-Oliver
    Wick, Wolfgang
    Heiland, Sabine
    Bendszus, Martin
    Schlemmer, Heinz-Peter
    Ladd, Mark Edward
    Bachert, Peter
    Radbruch, Alexander
    PLOS ONE, 2015, 10 (03):
  • [22] Imaging human teeth by phosphorus magnetic resonance with nuclear Overhauser enhancement
    Sun, Yi
    Brauckmann, Ole
    Nixdorf, Donald R.
    Kentgens, Arno
    Garwood, Michael
    Idiyatullin, Djaudat
    Heerschap, Arend
    SCIENTIFIC REPORTS, 2016, 6
  • [23] Triple-quantum-filtered sodium imaging of the human brain at 4.7 T
    Tsang, Adrian
    Stobbe, Robert W.
    Beaulieu, Christian
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1633 - 1643
  • [24] Quantitative assessment of the effects of water proton concentration and water T1 changes on amide proton transfer (APT) and nuclear overhauser enhancement (NOE) MRI: The origin of the APT imaging signal in brain tumor
    Lee, Dong-Hoon
    Heo, Hye-Young
    Zhang, Kai
    Zhang, Yi
    Jiang, Shanshan
    Zhao, Xuna
    Zhou, Jinyuan
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (02) : 855 - 863
  • [25] Imaging of amide proton transfer and nuclear Overhauser enhancement in ischemic stroke with corrections for competing effects
    Li, Hua
    Zu, Zhongliang
    Zaiss, Moritz
    Khan, Imad S.
    Singer, Robert J.
    Gochberg, Daniel F.
    Bachert, Peter
    Gore, John C.
    Xu, Junzhong
    NMR IN BIOMEDICINE, 2015, 28 (02) : 200 - 209
  • [26] High-resolution imaging of magnetisation transfer and nuclear Overhauser effect in the human visual cortex at 7 T
    Mougin, Olivier
    Clemence, Matthew
    Peters, Andrew
    Pitiot, Alain
    Gowland, Penny
    NMR IN BIOMEDICINE, 2013, 26 (11) : 1508 - 1517
  • [27] Reassembled saturation transfer (REST) MR images at 2 B1 values for in vivo exchange-dependent imaging of amide and nuclear Overhauser enhancement
    Chen, Yanrong
    Dang, Xujian
    Hu, Wanting
    Sun, Yaozong
    Bai, Yan
    Wang, Xiaoli
    He, Xiaowei
    Wang, Meiyun
    Song, Xiaolei
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) : 620 - 635
  • [28] Magnetization Transfer Contrast-Suppressed Imaging of Amide Proton Transfer and Relayed Nuclear Overhauser Enhancement Chemical Exchange Saturation Transfer Effects in the Human Brain at 7T
    Xu, Xiang
    Yadav, Nirbhay N.
    Zeng, Haifeng
    Jones, Craig K.
    Zhou, Jinyuan
    van Zijl, Peter C. M.
    Xu, Jiadi
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 88 - 96
  • [29] Imaging Amide Proton Transfer and Nuclear Overhauser Enhancement Using Chemical Exchange Rotation Transfer (CERT)
    Zu, Zhongliang
    Xu, Junzhong
    Li, Hua
    Chekmenev, Eduard Y.
    Quarles, C. Chad
    Does, Mark D.
    Gore, John C.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 471 - 476
  • [30] MR imaging of the amide-proton transfer effect and the pH-insensitive nuclear overhauser effect at 9.4 T
    Jin, Tao
    Wang, Ping
    Zong, Xiaopeng
    Kim, Seong-Gi
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) : 760 - 770