Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode

被引:1
|
作者
Burc, Muammer [1 ]
Titretir Duran, Serap [1 ]
Gungor, Oznur [1 ]
Karagozler, Ali Ersin [2 ]
机构
[1] Inonu Univ, Fac Arts & Sci, Dept Chem, TR-44280 Malatya, Turkiye
[2] Adnan Menderes Univ, Fac Arts & Sci, Dept Chem, TR-09010 Aydin, Turkiye
关键词
Gentamicin; beta-cyclodextrin; p-toluene sulfonic acid; Glassy carbon electrode; Sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL-PREPARATIONS; ELECTROCHEMICAL DETECTION; SENSITIVE DETECTION; HUMAN SERUM; SULFATE; SENSOR; WATER; ELECTROPOLYMERIZATION; NANOPARTICLES;
D O I
10.1007/s00289-023-05011-0
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
In this study, an effective electrochemical method based on modified glassy carbon electrode was developed for the determination of gentamicin. Firstly, the poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode as gentamicin selective electrode was prepared by electropolymerization technique. In situ electropolymerization of beta-cyclodextrin and p-toluene sulfonic acid was conducted on bare glassy carbon electrode by controlled potential cycling. Characterization of the prepared poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode was performed using cyclic voltammetry and electrochemical impedance spectroscopy. Then, the effects of various parameters were investigated using square wave anodic stripping voltammetry in citrate buffer containing 4.0 mmol L-1 gentamicin. The calibration graph plotted over the range of 0.06-4.0 mmol L-1 gentamicin concentration showed high linearity. Correlation coefficient, detection limit and quantitation limit were obtained from the calibration graph as 0.9999, 3.7 mu mol L-1 and 12.4 mu mol L-1, respectively. According to these results, it is seen that the prepared poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode can be successfully used for the determination of gentamicin in many pharmacological, medical and biochemical applications.
引用
收藏
页码:6381 / 6403
页数:23
相关论文
共 50 条
  • [31] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    J. F. van Staden
    M. Matoetoe
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 624 - 628
  • [32] Determination of copper by anodic stripping voltammetry on a glassy carbon electrode using a continuous flow system
    vanStaden, JF
    Matoetoe, M
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06): : 624 - 628
  • [33] CARBON PASTE ELECTRODE MODIFIED WITH Bi NANOPARTICLES - CARBON XEROGEL FOR Pb2+ DETERMINATION BY SQUARE WAVE ANODIC STRIPPING VOLTAMMETRY
    Deac, Aglaia Raluca
    Cotet, Liviu Cosmin
    Turdean, Graziella Liana
    Muresan, Liana Maria
    REVUE ROUMAINE DE CHIMIE, 2015, 60 (7-8) : 697 - 705
  • [34] Voltammetric Determination of UricAcid on Poly(p-Aminobenzene Sulfonic Acid)-Modified Glassy Carbon Electrode
    Sadikoglu, Murat
    Taskin, Gamze
    Demirtas, Fatma Gul
    Selvi, Bedrettin
    Barut, Mustafa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 11550 - 11557
  • [35] Determination of copper ion by square wave anodic stripping voltammetry at antimony trioxide-modified carbon nanotube paste electrode
    Mahsa Majidian
    Jahan Bakhsh Raoof
    Sayed Reza Hosseini
    Reza Ojani
    Journal of the Iranian Chemical Society, 2017, 14 : 1263 - 1270
  • [36] Determination of copper ion by square wave anodic stripping voltammetry at antimony trioxide-modified carbon nanotube paste electrode
    Majidian, Mahsa
    Raoof, Jahan Bakhsh
    Hosseini, Sayed Reza
    Ojani, Reza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2017, 14 (06) : 1263 - 1270
  • [37] Determination of vitamin K1 using square wave adsorptive stripping voltammetry at solid glassy carbon electrode
    Sys, Milan
    Jashari, Granit
    Svecova, Blanka
    Arbneshi, Tahir
    Metelka, Radovan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 821 : 10 - 15
  • [38] Square wave anodic stripping determination of silver using a carbon paste electrode modified with a strong acid ion-exchanger
    Gellon, H
    González, PS
    Fontan, CA
    ANALYTICAL LETTERS, 2003, 36 (13) : 2749 - 2765
  • [39] Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode
    Mohamed S. Ibrahim
    Yassien M. Temerk
    Moustafa M. Kamal
    Gamal A.-W. Ahmed
    Hossieny S. M. Ibrahim
    Microchimica Acta, 2004, 144 : 249 - 256
  • [40] Determination of Copper in Wine by Anodic Stripping Voltammetry with Rotating Glassy Carbon and Microfiber Carbon Electrode
    Suznjevic, Desanka Z.
    Pastor, Ferenc T.
    Gorjanovic, Stanislava Z.
    CROATICA CHEMICA ACTA, 2017, 90 (02) : 353 - 357