Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode

被引:1
|
作者
Burc, Muammer [1 ]
Titretir Duran, Serap [1 ]
Gungor, Oznur [1 ]
Karagozler, Ali Ersin [2 ]
机构
[1] Inonu Univ, Fac Arts & Sci, Dept Chem, TR-44280 Malatya, Turkiye
[2] Adnan Menderes Univ, Fac Arts & Sci, Dept Chem, TR-09010 Aydin, Turkiye
关键词
Gentamicin; beta-cyclodextrin; p-toluene sulfonic acid; Glassy carbon electrode; Sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL-PREPARATIONS; ELECTROCHEMICAL DETECTION; SENSITIVE DETECTION; HUMAN SERUM; SULFATE; SENSOR; WATER; ELECTROPOLYMERIZATION; NANOPARTICLES;
D O I
10.1007/s00289-023-05011-0
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
In this study, an effective electrochemical method based on modified glassy carbon electrode was developed for the determination of gentamicin. Firstly, the poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode as gentamicin selective electrode was prepared by electropolymerization technique. In situ electropolymerization of beta-cyclodextrin and p-toluene sulfonic acid was conducted on bare glassy carbon electrode by controlled potential cycling. Characterization of the prepared poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode was performed using cyclic voltammetry and electrochemical impedance spectroscopy. Then, the effects of various parameters were investigated using square wave anodic stripping voltammetry in citrate buffer containing 4.0 mmol L-1 gentamicin. The calibration graph plotted over the range of 0.06-4.0 mmol L-1 gentamicin concentration showed high linearity. Correlation coefficient, detection limit and quantitation limit were obtained from the calibration graph as 0.9999, 3.7 mu mol L-1 and 12.4 mu mol L-1, respectively. According to these results, it is seen that the prepared poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode can be successfully used for the determination of gentamicin in many pharmacological, medical and biochemical applications.
引用
收藏
页码:6381 / 6403
页数:23
相关论文
共 50 条
  • [21] Determination of Rutin on the Poly(p-aminobenzene sulfonic acid) Modified Glassy Carbon Electrode
    Chen, Xiaoyin
    Wang, Zonghua
    Zhang, Feifei
    Zhu, Lingyan
    Li, Yanhui
    Xia, Yanzhi
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (04) : 475 - 478
  • [22] Square Wave Anodic Stripping Voltammetric Determination of Paracetamol at Poly Luminol/Functionalized Multi-Walled Carbon Nanotubes Modified Glassy Carbon Electrode
    Gholivand, Mohammad Bagher
    Ahmadi, Elahe
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2019, 55 (12) : 1151 - 1161
  • [24] Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    Xiuhui He
    Li Chen
    Xuan Xie
    Zhaohong Su
    Cong Qin
    Ying Liu
    Ming Ma
    Shouzhuo Yao
    Le Deng
    Qingji Xie
    Yun Tian
    Dilan Qin
    Yueping Luo
    Microchimica Acta, 2012, 176 : 81 - 89
  • [25] Square wave anodic stripping voltammetric determination of lead(II) using a glassy carbon electrode modified with a lead ionophore and multiwalled carbon nanotubes
    He, Xiuhui
    Chen, Li
    Xie, Xuan
    Su, Zhaohong
    Qin, Cong
    Liu, Ying
    Ma, Ming
    Yao, Shouzhuo
    Deng, Le
    Xie, Qingji
    Tian, Yun
    Qin, Dilan
    Luo, Yueping
    MICROCHIMICA ACTA, 2012, 176 (1-2) : 81 - 89
  • [26] Poly(catechol) film modified glassy carbon electrode for ultratrace determination of cerium(III) by differential pulse anodic stripping voltammetry
    Khoo, SB
    Zhu, J
    ELECTROANALYSIS, 1999, 11 (08) : 546 - 552
  • [27] Anodic stripping voltammetry of arsenic determination with edible mushroom-nafion-modified glassy carbon electrode
    Salinas, Arturo
    Trivino, Juan Jose
    Alvarez-Lueje, Alejandro
    Pizarro, Isabel
    Segura, Rodrigo
    Arancibia, Veronica
    TALANTA, 2024, 277
  • [28] Lead determination by anodic stripping voltammetry using a p-phenylenediamine modified carbon paste electrode
    Adraoui, I
    El Rhazi, M
    Amine, A
    Idrissi, L
    Curulli, A
    Palleschi, G
    ELECTROANALYSIS, 2005, 17 (08) : 685 - 693
  • [29] Highly sensitive electrocatalytic determination of pyrazinamide using a modified poly(glycine) glassy carbon electrode by square-wave voltammetry
    Bruno R. L. Ferraz
    Fernando R. F. Leite
    Andréa R. Malagutti
    Journal of Solid State Electrochemistry, 2016, 20 : 2509 - 2516
  • [30] Highly sensitive electrocatalytic determination of pyrazinamide using a modified poly(glycine) glassy carbon electrode by square-wave voltammetry
    Ferraz, Bruno R. L.
    Leite, Fernando R. F.
    Malagutti, Andrea R.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (09) : 2509 - 2516