Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode

被引:1
|
作者
Burc, Muammer [1 ]
Titretir Duran, Serap [1 ]
Gungor, Oznur [1 ]
Karagozler, Ali Ersin [2 ]
机构
[1] Inonu Univ, Fac Arts & Sci, Dept Chem, TR-44280 Malatya, Turkiye
[2] Adnan Menderes Univ, Fac Arts & Sci, Dept Chem, TR-09010 Aydin, Turkiye
关键词
Gentamicin; beta-cyclodextrin; p-toluene sulfonic acid; Glassy carbon electrode; Sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; PHARMACEUTICAL-PREPARATIONS; ELECTROCHEMICAL DETECTION; SENSITIVE DETECTION; HUMAN SERUM; SULFATE; SENSOR; WATER; ELECTROPOLYMERIZATION; NANOPARTICLES;
D O I
10.1007/s00289-023-05011-0
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
In this study, an effective electrochemical method based on modified glassy carbon electrode was developed for the determination of gentamicin. Firstly, the poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode as gentamicin selective electrode was prepared by electropolymerization technique. In situ electropolymerization of beta-cyclodextrin and p-toluene sulfonic acid was conducted on bare glassy carbon electrode by controlled potential cycling. Characterization of the prepared poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode was performed using cyclic voltammetry and electrochemical impedance spectroscopy. Then, the effects of various parameters were investigated using square wave anodic stripping voltammetry in citrate buffer containing 4.0 mmol L-1 gentamicin. The calibration graph plotted over the range of 0.06-4.0 mmol L-1 gentamicin concentration showed high linearity. Correlation coefficient, detection limit and quantitation limit were obtained from the calibration graph as 0.9999, 3.7 mu mol L-1 and 12.4 mu mol L-1, respectively. According to these results, it is seen that the prepared poly beta-cyclodextrin-p-toluene sulfonic acid/glassy carbon electrode can be successfully used for the determination of gentamicin in many pharmacological, medical and biochemical applications.
引用
收藏
页码:6381 / 6403
页数:23
相关论文
共 50 条
  • [1] Determination of gentamicin by using square wave anodic stripping voltammetry with poly (β-cyclodextrin-p-toluene sulfonic acid) modified glassy carbon electrode
    Muammer Burç
    Serap Titretir Duran
    Öznur Güngör
    Ali Ersin Karagözler
    Polymer Bulletin, 2024, 81 : 6381 - 6403
  • [2] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Wen Jiao Yi
    Yang Li
    Gu Ran
    Hong Qun Luo
    Nian Bing Li
    Microchimica Acta, 2012, 179 : 171 - 177
  • [3] A glassy carbon electrode modified with antimony and poly(p-aminobenzene sulfonic acid) for sensing lead(II) by square wave anodic stripping voltammetry
    Yi, Wen Jiao
    Li, Yang
    Ran, Gu
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2012, 179 (1-2) : 171 - 177
  • [4] Determination of oleuropein using multiwalled carbon nanotube modified glassy carbon electrode by adsorptive stripping square wave voltammetry
    Cittan, Mustafa
    Kocak, Suleyman
    Celik, Ali
    Dost, Kenan
    TALANTA, 2016, 159 : 148 - 154
  • [5] Determination of levofloxacin in human urine by adsorptive square-wave anodic stripping voltammetry on a glassy carbon electrode
    Radi, A
    El-Sherif, Z
    TALANTA, 2002, 58 (02) : 319 - 324
  • [6] Sensitive determination of paraquat by square wave anodic stripping voltammetry with chitin modified carbon paste electrode
    El Harmoudi, H.
    Achak, M.
    Farahi, A.
    Lahrich, S.
    El Gaini, L.
    Abdennouri, M.
    Bouzidi, A.
    Bakasse, M.
    El Mhammedi, M. A.
    TALANTA, 2013, 115 : 172 - 177
  • [7] Determination of vitamin E in margarines and edible oils using square wave anodic stripping voltammetry with a glassy carbon paste electrode
    Sys, Milan
    Svecova, Blanka
    Svancara, Ivan
    Metelka, Radovan
    FOOD CHEMISTRY, 2017, 229 : 621 - 627
  • [8] A stannum/bismuth/poly(p-aminobenzene sulfonic acid) film electrode for measurement of Cd(II) using square wave anodic stripping voltammetry
    Xiong, Chang Hong
    Luo, Hong Qun
    Li, Nian Bing
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 651 (01) : 19 - 23
  • [9] Determination of mercury at a dithizone-modified glassy carbon electrode by anodic stripping voltammetry
    Huang, WS
    Zhang, SH
    ANALYTICAL SCIENCES, 2002, 18 (02) : 187 - 189
  • [10] Determination of Mercury at a Dithizone-Modified Glassy Carbon Electrode by Anodic Stripping Voltammetry
    Wensheng Huang
    Shenghui Zhang
    Analytical Sciences, 2002, 18 : 187 - 189