Prediction of breast dose in chest CT examinations using adaptive neuro-fuzzy inference system (ANFIS)

被引:1
作者
Bahonar, Bahareh Moradmand [1 ]
Changizi, Vahid [1 ]
Ebrahiminia, Ali [2 ]
Baradaran, Samaneh [3 ]
机构
[1] Univ Tehran Med Sci, Dept Radiol & Radiotherapy Technol, Tehran, Iran
[2] Guilan Univ Med Sci, Sch Med, Dept Med Phys, Rasht, Iran
[3] Nucl Sci & Technol Res Inst, Tehran, Iran
关键词
CT; Radiation dosimetry; TLD; Breast dose; ANFIS; DOSIMETRY; REDUCTION; EXPOSURE; QUALITY; RISKS;
D O I
10.1007/s13246-023-01276-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In chest computed tomography (CT), the breasts located within the scan range receive a substantial radiation dose. Due to the risk of breast-related carcinogenesis, analyzing the breast dose for justification of CT examinations seems necessary. The main goal of this study is to overcome the limitations of conventional dosimetry methods, such as thermoluminescent dosimeters (TLDs) by introducing the adaptive neuro-fuzzy inference system (ANFIS) approach. In this study, the breast dose of 50 adult female patients who underwent chest CT examinations was measured directly by TLDs. Then, the ANFIS model was developed with four inputs including dose length product (DLP), volumetric CT dose index (CTDIvol), total mAs, and size-specific dose estimate (SSDE), and one output (TLD dose). Additionally, multiple linear regression (MLR) as a traditional prediction model was used for linear modeling and its results were compared with the ANFIS. The TLD reader results showed that the breast dose value was 12.37 +/- 2.46 mGy. Performance indices of the ANFIS model, including root mean square error (RMSE) and correlation coefficient (R), were calculated at 0.172 and 0.93 for the testing dataset, respectively. Also, the ANFIS model had superior performance in predicting the breast dose than the MLR model (R = 0.805). This study demonstrates that the proposed ANFIS model is efficient for patient dose prediction in CT scans. Therefore, intelligence models such as ANFIS are suggested to estimate and optimize patient dose in CT examinations.
引用
收藏
页码:1071 / 1080
页数:10
相关论文
共 41 条
  • [1] Radiation Risk From CT: Implications for Cancer Screening
    Albert, Jeffrey M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (01) : W81 - W87
  • [2] Investigation of Exposure Factors for Various Breast Composition and Thicknesses in Digital Screening Mammography Related to Breast Dose
    Alkhalifah, Khaled
    Brindhaban, Ajit
    [J]. MEDICAL PRINCIPLES AND PRACTICE, 2018, 27 (03) : 211 - 216
  • [3] American Association of Physicists in Medicine, 2014, The Report of AAPM Task Group, P1
  • [4] American Association of Physicists in Medicine, 2011, Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations (Task Group 204)
  • [5] [Anonymous], 2012, Human Health Series
  • [6] Assessing the accuracy of ANFIS, EEMD-GRNN, PCR, and MLR models in predicting PM2.5
    Ausati, Shadi
    Amanollahi, Jamil
    [J]. ATMOSPHERIC ENVIRONMENT, 2016, 142 : 465 - 474
  • [7] Medical Imaging: From Roentgen to the Digital Revolution, and Beyond
    Bercovich, Eyal
    Javitt, Marcia C.
    [J]. RAMBAM MAIMONIDES MEDICAL JOURNAL, 2018, 9 (04):
  • [8] Current Applications and Future Impact of Machine Learning in Radiology
    Choy, Garry
    Khalilzadeh, Omid
    Michalski, Mark
    Do, Synho
    Samir, Anthony E.
    Pianykh, Oleg S.
    Geis, J. Raymond
    Pandharipande, Pari V.
    Brink, James A.
    Dreyer, Keith J.
    [J]. RADIOLOGY, 2018, 288 (02) : 318 - 328
  • [9] Low-dose lung computed tomography screening before age 55: estimates of the mortality reduction required to outweigh the radiation-induced cancer risk
    de Gonzalez, Amy Berrington
    Kim, Kwang Pyo
    Berg, Christine D.
    [J]. JOURNAL OF MEDICAL SCREENING, 2008, 15 (03) : 153 - 158
  • [10] Desterro FS, 2017, IMPR RAD DOS EST DUE