Tension band high-strength suture combined with absorbable cannulated screws for treating transverse patellar fractures: finite element analysis and clinical study

被引:2
|
作者
Xiang, Feifan [1 ,2 ,3 ]
Xiao, Yukun [2 ]
Li, Dige [2 ]
Ma, Wenzhe [1 ]
Chen, Yue [3 ,4 ,5 ]
Yang, Yunkang [2 ]
机构
[1] Macau Univ Sci & Technol, State Key Lab Qual Res Chinese Med, Macau, Peoples R China
[2] Southwest Med Univ, Affiliated Hosp, Dept Orthoped, Luzhou, Peoples R China
[3] Southwest Med Univ, Affiliated Hosp, Dept Nucl Med, Luzhou, Peoples R China
[4] Nucl Med & Mol Imaging Key Lab Sichuan Prov, Luzhou, Peoples R China
[5] Southwest Med Univ, Inst Nucl Med, Luzhou, Peoples R China
来源
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY | 2024年 / 12卷
基金
中国国家自然科学基金;
关键词
transverse patellar fractures; absorbable cannulated screws; ultrabraid highstrength suture; tension band; finite element analysis; retrospective clinical study; BRAIDED POLYESTER SUTURE; FIXATION; COMPLICATIONS;
D O I
10.3389/fbioe.2024.1340482
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objective: Few reports exist on the treatment of transverse patellar fractures (TPFs) using absorbable cannulated screws and high-strength sutures, and most screws and sutures lack good biomechanics and clinical trials. Therefore, this study aimed to demonstrate the biomechanical stability and clinical efficacy of tension-band high-strength sutures combined with absorbable cannulated screws (TBSAS) in treating TPFs (AO/OTA 34 C1). Methods: Finite element models of five internal fixation schemes were established: tension-band wire with K-wire (TBW), TBW with cerclage wire (TBWC), TBW with headless pressure screws (TBWHS), TBW with full-thread screws (TBWFS), and TBSAS. We comprehensively compared the biomechanical characteristics of the TBSAS treatment scheme during knee flexion and extension. Forty-one patients with TPFs in our hospital between January 2020 and August 2022 were retrospectively enrolled and divided into the TBSAS (n = 22) and TBWC (n = 19) groups. Clinical and follow-up outcomes, including operative time, visual analog scale (VAS) pain score, postoperative complications, Bostman score, and final knee range of motion, were compared between both groups. Results: Finite element analysis (FEA) showed that TBWHS and TBWFS achieved the minimum mean fracture interface relative displacement during knee flexion (45 degrees, 0-500 N bending load) and full extension (0 degrees, 0-500 N axial load). There was no significant difference between TBSAS (0.136 mm) and TBWC (0.146 mm) during knee flexion (500 N); however, TBSAS displacement was smaller (0.075 mm) during full extension (500 N). Furthermore, the stress results for the internal fixation and the patella were generally lower when using TBSAS. Retrospective clinical studies showed that the TBSAS group had a shorter operative time, lower VAS pain score at 1 and 2 months postoperatively, better Bostman knee function score at 3 and 9 months postoperatively, and better final knee joint motion than the TBWC group (all p < 0.05). There were five cases (26.3%) of internal fixation stimulation complications in the TBWC group. Conclusion: TBSAS demonstrated excellent safety and effectiveness in treating TPFs. It is sufficient to meet the needs of TPF fixation and early functional exercise and effectively reduces metal internal fixation-induced complications and secondary surgery-induced trauma.
引用
收藏
页数:12
相关论文
共 22 条
  • [1] A novel technique for treating simple transverse patellar fractures using cannulated screws: a cadaveric and clinical study
    Han, Feng
    Zhong, Zhenjia
    Zhou, Ming
    Chen, Qi
    Liu, Yinan
    Rui, Yongjun
    Li, Fengfeng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [2] Comparison of the Effect of Diameters and Numbers of Cannulated Screws and Headless Compression Screws on the Reduction Stability in Transverse Patellar Fractures: A Finite Element Model Study
    Ugur, Levent
    Karadeniz, Selami
    Yildiz, Aytac
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2017, 7 (10) : 919 - 925
  • [3] An innovative anti-rotation tension band wiring for treating transverse patellar fractures: finite element analysis and mechanical testing
    Zhang, Ze
    Sun, Fengpo
    Zhang, Tongyi
    Wen, Liangyuan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [4] The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study
    Li, Yihan
    Tian, Qingxian
    Leng, Kunpeng
    Guo, Meng
    BMC SURGERY, 2022, 22 (01)
  • [5] The clinical outcomes and complications of combined fixation with cannulated screws and the modified Pyrford technique for the treatment of transverse patellar fractures: a case series study
    Yihan Li
    Qingxian Tian
    Kunpeng Leng
    Meng Guo
    BMC Surgery, 22
  • [6] Percutaneous minimally invasive treatment of transverse patellar fracture using cannulated screws combined with high-strength sutures and Nice knots: a retrospective study
    Jia, Xueyuan
    Wu, Yongwei
    Rui, Yongjun
    Ma, Yunhong
    Liu, Jun
    Wang, Jianbing
    Wang, Yapeng
    Wang, Peng
    Luo, Junhao
    Zhou, Ming
    ANNALS OF PALLIATIVE MEDICINE, 2022, 11 (03) : 1085 - 1092
  • [7] Comparison of Functional and Radiological Outcomes of Transverse Patellar Fractures Fixed with Tension Band Fixation Using Cannulated Screws and Kirschner Wires: A Prospective Randomized Study
    Drolia, Nikhil
    Sinha, Siddhartha
    Paneru, Shiva Raj
    Kumar, Arvind
    Jameel, Javed
    Kumar, Sandeep
    Shrestha, Bikram
    Khanal, Guru P.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (03) : 369 - 376
  • [8] A combined tension-band braided polyester and suture button technique is a valuable treatment alternative for transverse patellar fractures in athletes
    Bukva B.
    D’Hooghe P.
    Poberaj B.
    Alkhelaifi K.
    Hutchinson M.
    Landreau P.
    MUSCULOSKELETAL SURGERY, 2019, 103 (3) : 283 - 287
  • [9] Morphological Characteristics of Inferior Pole Patellar Fractures and a Finite-Element Analysis Combined With a Retrospective Clinical Study of Anchor Suture and Titanium Cable Cerclage Treatment
    Hu, Zhenghui
    Sun, Chen
    Heng, Hongquan
    Li, Jian
    Chen, Hainan
    Chen, Fuchao
    Su, Peng
    Wang, Dengfeng
    ORTHOPAEDIC SURGERY, 2025, : 1045 - 1056
  • [10] Dual tension band technique for patellar fractures involving articular surface and inferior pole: a retrospective cohort study and finite element analysis
    Gao, Yanchun
    Wu, Guifa
    Zhu, Hongli
    Bian, Kaixin
    Wu, Di
    Wei, Haifeng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2025, 13