Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry

被引:14
作者
Cheng, Jing [1 ]
Zhang, Haidong [2 ,3 ,4 ,5 ]
Liu, Hailin [6 ]
Li, Junying [7 ]
Wang, Hom-Lay [8 ,10 ]
Tao, Xian [9 ,11 ]
机构
[1] Xiamen Med Coll, Stomatol Hosp, Dept Gen Dent, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen, Peoples R China
[2] Peking Univ, Sch & Hosp Stomatol, Dept Periodontol, Beijing, Peoples R China
[3] Natl Ctr Stomatol, Beijing, Peoples R China
[4] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[5] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[6] Jingpin Med Technol Beijing Co Ltd, Beijing, Peoples R China
[7] Univ Michigan, Dept Biol & Mat Sci & Prosthodont, Sch Dent, Ann Arbor, MI USA
[8] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI USA
[9] Stomatol Hosp, Dept Prosthodont, Xiamen Key Lab Stomatol Dis Diag & Treatment, Xiamen Med Coll, Xiamen, Peoples R China
[10] Univ Michigan, Dept Periodont & Oral Med, Sch Dent, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[11] Xiamen Med Coll, Stomatol Hosp, Dept Prosthodont, 1309 Lvling Rd, Xiamen 361008, Fujian, Peoples R China
关键词
accuracy; digital impression; intraoral scanning; stereophotogrammetry; MULTIPLE IMPLANTS; PART I; MISFIT; PROSTHESES; POSITIONS; SURVIVAL; IMPACT;
D O I
10.1111/clr.14252
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this in vitro study was to compare the trueness and precision of complete arch implant impressions using conventional impression, intraoral scanning with and without splinting, and stereophotogrammetry. Materials and Methods: An edentulous model with six implants was used in this study. Four implant impression techniques were compared: the conventional impression (CI), intraoral scanning (IOS) without splinting, intraoral scanning with splinting (MIOS), and stereophotogrammetry (SPG). An industrial blue light scanner was used to generate the baseline scan from the model. The CI was captured with a laboratory scanner. The reference best-fit method was then applied in the computer-aided design (CAD) software to compute the three-dimensional, angular, and linear discrepancies among the four impression techniques. The root mean square (RMS) 3D discrepancies in trueness and precision between the four impression groups were analyzed with a Kruskal-Wallis test. Trueness and precision between single analogs were assessed using generalized estimating equations. Results: Significant differences in the overall trueness (p = .017) and precision (p < .001) were observed across four impression groups. The SPG group exhibited significantly smaller RMS 3D deviations than the CI, IOS, and MIOS groups (p < .05), with no significant difference detected among the latter three groups (p > .05). Conclusions: Stereophotogrammetry showed superior trueness and precision, meeting misfit thresholds for implant-supported complete arch prostheses. Intraoral scanning, while accurate like conventional impressions, exhibited cross-arch angular and linear deviations. Adding a splint to the scan body did not improve intraoral scanning accuracy.
引用
收藏
页码:560 / 572
页数:13
相关论文
共 68 条
  • [1] Al-Turki LEE, 2002, INT J PROSTHODONT, V15, P38
  • [2] Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study
    Andriessen, Frank S.
    Riikens, David R.
    van der Meer, Wither J.
    Wismeijer, Daniell W.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) : 186 - 194
  • [3] [Anonymous], 1994, Accuracy (trueness and precision) of measurement methods and results - Part 1: General principies and defmitions
  • [4] Influence of Implant Scanbody Wear on the Accuracy of Digital Impression for Complete-Arch: A Randomized In Vitro Trial
    Arcuri, Lorenzo
    Lio, Fabrizio
    Campana, Veronica
    Mazzetti, Vincenzo
    Federici, Francesca Romana
    Nardi, Alessandra
    Galli, Massimo
    [J]. MATERIALS, 2022, 15 (03)
  • [5] Accuracy of digital impressions for implant-supported complete-arch prosthesis when using an auxiliary geometry device
    Arikan, Hale
    Muhtarogullari, Mehmet
    Uzel, Sema Merve
    Guncu, Mustafa Baris
    Aktas, Guliz
    Marshall, Lindsay Simone
    Turkyilmaz, Ilser
    [J]. JOURNAL OF DENTAL SCIENCES, 2023, 18 (02) : 808 - 813
  • [6] Bergin JM, 2013, J PROSTHET DENT, V110, P243, DOI 10.1016/S0022-3913(13)60370-4
  • [7] Effect of simulated intraoral variables on the accuracy of a photogrammetric imaging technique for complete-arch implant prostheses
    Bratos, Manuel
    Bergin, Jumping M.
    Rubenstein, Jeffrey E.
    Sorensen, John A.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02) : 232 - 241
  • [8] Clinical efficiency and patient preference of digital and conventional workflow for single implant crowns using immediate and regular digital impression: A meta-analysis
    de Oliveira, Nathalia R. Cunha
    Pigozzo, Monica N.
    Sesma, Newton
    Lagana, Dalva Cruz
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (08) : 669 - 686
  • [9] Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners
    Di Fiore, Adolfo
    Meneghello, Roberto
    Graiff, Lorenzo
    Savio, Gianpaolo
    Vigolo, Paolo
    Monaco, Carlo
    Stellini, Edoardo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 396 - 403
  • [10] A COMPARISON OF IMPRESSION MATERIALS FOR COMPLETE-ARCH FIXED PARTIAL DENTURES
    DOUNIS, GS
    ZIEBERT, GJ
    DOUNIS, KS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1991, 65 (02) : 165 - 169