Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography

被引:0
|
作者
Takahashi, Junji [1 ,2 ]
Machida, Yoshio [2 ]
Fukuzawa, Kei [1 ]
Tsuji, Yoshinori [1 ]
Ohmoto-Sekine, Yuki [3 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol Technol, 2-2-2 Toranomon,Minato Ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Hlth Sci, 2-1 Seiryo Machi,Aoba Ku, Sendai, Miyagi 9808575, Japan
[3] Toranomon Gen Hosp, Hlth Management Ctr, 2-2-2 Toranomon,Minato-ku, Tokyo 1058470, Japan
关键词
Coronary magnetic resonance angiography; Image quality; Compressed sensing; Acceleration factor; Denoising factor; STATE FREE PRECESSION; PARTIALLY PARALLEL ACQUISITIONS; MR-ANGIOGRAPHY; RELAXATION; NOISE; TIME;
D O I
10.1007/s12194-024-00787-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using numerical indices and visual evaluation, we evaluated the dependence of coronary-artery depictability on the denoising parameter in compressed sensing magnetic resonance angiography (CS-MRA). This study was conducted to clarify the acceleration factor (AF) and denoising factor (DF) dependence of CS-MRA image quality. Vascular phantoms and clinical images were acquired using three-dimensional CS-MRA on a clinical 1.5 T system. For the phantom measurements, we compared the full width at half maximum (FWHM), sharpness, and contrast ratio of the vascular profile curves for various AFs and DFs. In the clinical cases, the FWHM, sharpness, contrast ratio, signal-to-noise ratio, noise level values, and visual evaluation results were compared for various DFs. Phantom image analyses demonstrated that the respective measurements of the FWHM, sharpness, and contrast ratios did not significantly change with an increase in AF. The FWHM and sharpness measurements slightly changed with the DF level. However, the contrast ratio tended to increase with an increase in the DF level. In the clinical cases, the FWHM and sharpness showed no significant differences, even when the DF level was changed. However, the contrast ratio tended to decrease as the DF level increased. When the DF levels of the clinical cases increased, the background signals of the myocardium, fat, and noise levels decreased. We investigated the dependence of the coronary-artery depictability on AF and DF using CS-MRA. Analysis of the coronary-artery profile curves indicated that a better image quality was achieved with a stronger DF on coronary CS-MRA.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 50 条
  • [41] Optimization of Regularization Parameters in Compressed Sensing of Magnetic Resonance Angiography: Can Statistical Image Metrics Mimic Radiologists' Perception?
    Akasaka, Thai
    Fujimoto, Koji
    Yamamoto, Takayuki
    Okada, Tomohisa
    Fushumi, Yasutaka
    Yamamoto, Akira
    Tanaka, Toshiyuki
    Togashi, Kaori
    PLOS ONE, 2016, 11 (01):
  • [42] Rapid 2D phase-contrast magnetic resonance angiography reconstruction algorithm via compressed sensing
    Dong-Hoon Lee
    Cheol-Pyo Hong
    Man-Woo Lee
    Bong-Soo Han
    Journal of the Korean Physical Society, 2013, 63 : 1072 - 1076
  • [43] Evaluation of Image Quality of Compressed Sensing Magnetic Resonance Images
    Kim, Seongho
    Oh, Jung Eun
    Kwon, Soon Yong
    Jang, Ji Sung
    Lee, Won Jeong
    Jeon, Min Cheol
    Kim, Jae Seok
    Lee, Mo Kwon
    Yoo, Se Jong
    JOURNAL OF MAGNETICS, 2022, 27 (04) : 514 - 521
  • [44] SPREAD SPECTRUM FOR COMPRESSED SENSING TECHNIQUES IN MAGNETIC RESONANCE IMAGING
    Wiaux, Y.
    Puy, G.
    Gruetter, R.
    Thiran, J. -Ph.
    Van De Ville, D.
    Vandergheynst, P.
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 756 - 759
  • [45] Magnetic Resonance Fingerprinting with compressed sensing and distance metric learning
    Wang, Zhe
    Li, Hongsheng
    Zhang, Qinwei
    Yuan, Jing
    Wang, Xiaogang
    NEUROCOMPUTING, 2016, 174 : 560 - 570
  • [46] Uncover This Tech Term: Compressed Sensing Magnetic Resonance Imaging
    Yoon, Sungjin
    Park, So Hyun
    Han, Dongyeob
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (12) : 1293 - 1297
  • [47] Long-Term Coronary Artery Evaluation Using Noncontrast-Enhanced Magnetic Resonance Angiography in Patients with Kawasaki Disease
    Nonaka, Haruki
    Tahara, Masahiro
    Yoshiura, Takayuki
    Urayama, Kotaro
    Okano, Mio
    Morikawa, Yuko
    Morita, Risa
    Sato, Tomoyasu
    PEDIATRIC CARDIOLOGY, 2024,
  • [48] Magnetic resonance coronary angiography in the era of multimodality imaging
    Androulakis, E.
    Mohiaddin, R.
    Bratis, K.
    CLINICAL RADIOLOGY, 2022, 77 (07) : E89 - E99
  • [49] Curvelets as a Sparse Basis for Compressed Sensing Magnetic Resonance Imaging
    Smith, David S.
    Arlinghaus, Lori R.
    Yankeelov, Thomas E.
    Welch, E. Brian
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [50] Reducing view-sharing using compressed sensing in time-resolved contrast-enhanced magnetic resonance angiography
    Rapacchi, Stanislas
    Natsuaki, Yutaka
    Plotnik, Adam
    Gabriel, Simon
    Laub, Gerhard
    Finn, J. Paul
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 474 - 481