Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography

被引:0
|
作者
Takahashi, Junji [1 ,2 ]
Machida, Yoshio [2 ]
Fukuzawa, Kei [1 ]
Tsuji, Yoshinori [1 ]
Ohmoto-Sekine, Yuki [3 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol Technol, 2-2-2 Toranomon,Minato Ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Hlth Sci, 2-1 Seiryo Machi,Aoba Ku, Sendai, Miyagi 9808575, Japan
[3] Toranomon Gen Hosp, Hlth Management Ctr, 2-2-2 Toranomon,Minato-ku, Tokyo 1058470, Japan
关键词
Coronary magnetic resonance angiography; Image quality; Compressed sensing; Acceleration factor; Denoising factor; STATE FREE PRECESSION; PARTIALLY PARALLEL ACQUISITIONS; MR-ANGIOGRAPHY; RELAXATION; NOISE; TIME;
D O I
10.1007/s12194-024-00787-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using numerical indices and visual evaluation, we evaluated the dependence of coronary-artery depictability on the denoising parameter in compressed sensing magnetic resonance angiography (CS-MRA). This study was conducted to clarify the acceleration factor (AF) and denoising factor (DF) dependence of CS-MRA image quality. Vascular phantoms and clinical images were acquired using three-dimensional CS-MRA on a clinical 1.5 T system. For the phantom measurements, we compared the full width at half maximum (FWHM), sharpness, and contrast ratio of the vascular profile curves for various AFs and DFs. In the clinical cases, the FWHM, sharpness, contrast ratio, signal-to-noise ratio, noise level values, and visual evaluation results were compared for various DFs. Phantom image analyses demonstrated that the respective measurements of the FWHM, sharpness, and contrast ratios did not significantly change with an increase in AF. The FWHM and sharpness measurements slightly changed with the DF level. However, the contrast ratio tended to increase with an increase in the DF level. In the clinical cases, the FWHM and sharpness showed no significant differences, even when the DF level was changed. However, the contrast ratio tended to decrease as the DF level increased. When the DF levels of the clinical cases increased, the background signals of the myocardium, fat, and noise levels decreased. We investigated the dependence of the coronary-artery depictability on AF and DF using CS-MRA. Analysis of the coronary-artery profile curves indicated that a better image quality was achieved with a stronger DF on coronary CS-MRA.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 50 条
  • [31] Comparison of Algorithms for Compressed Sensing of Magnetic Resonance Images
    Jelena, Badnjar
    2015 4TH MEDITERRANEAN CONFERENCE ON EMBEDDED COMPUTING (MECO), 2015, : 303 - 306
  • [32] Prognostic Value of Coronary Magnetic Resonance Angiography for Prediction of Cardiac Events in Patients With Suspected Coronary Artery Disease
    Yoon, Yeonyee E.
    Kitagawa, Kakuya
    Kato, Shingo
    Ishida, Masaki
    Nakajima, Hiroshi
    Kurita, Tairo
    Ito, Masaaki
    Sakuma, Hajime
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (22) : 2316 - 2322
  • [33] Additive value of 3T cardiovascular magnetic resonance coronary angiography for detecting coronary artery disease
    Lijun Zhang
    Xiantao Song
    Li Dong
    Jianan Li
    Ruiyu Dou
    Zhanming Fan
    Jing An
    Debiao Li
    Journal of Cardiovascular Magnetic Resonance, 20
  • [34] Multi-phase coronary magnetic resonance angiography improves delineation of coronary arteries
    Zitzelsberger, Tanja
    Krumm, Patrick
    Hornung, Andreas
    Kramer, Ulrich
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Schick, Fritz
    Sieverding, Ludger
    Martirosian, Petros
    ACTA RADIOLOGICA, 2019, 60 (11) : 1422 - 1429
  • [35] The diagnostic value of non-contrast magnetic resonance coronary angiography in the assessment of coronary artery disease: A systematic review and meta-analysis
    Zahergivar, Aryan
    Kocher, Madison
    Waltz, Jeffrey
    Kabakus, Ismail
    Chamberlin, Jordan
    Akkaya, Selcuk
    Agha, Ali M.
    Schoepf, U. Joseph
    Burt, Jeremy R.
    HELIYON, 2021, 7 (03)
  • [36] Compressed sensing time-of-flight magnetic resonance angiography with high spatial resolution for evaluating intracranial aneurysms: comparison with digital subtraction angiography
    Kim, Donghyun
    Heo, Young Jin
    Jeong, Hae Woong
    Baek, Jin Wook
    Shin, Gi Won
    Jin, Sung-Chul
    Baek, Hye Jin
    Ryu, Kyeong Hwa
    Kim, Kang Soo
    Kim, InSeong
    NEURORADIOLOGY JOURNAL, 2021, 34 (03): : 213 - 221
  • [37] Magnetic resonance angiography of splanchnic artery aneurysms and pseudoaneurysms
    Pilleul, F
    Forest, J
    Beuf, O
    JOURNAL DE RADIOLOGIE, 2006, 87 (02): : 127 - 131
  • [38] Magnetic resonance coronary angiography in the era of multimodality imaging
    Androulakis, E.
    Mohiaddin, R.
    Bratis, K.
    CLINICAL RADIOLOGY, 2022, 77 (07) : E89 - E99
  • [39] Optimization of Regularization Parameters in Compressed Sensing of Magnetic Resonance Angiography: Can Statistical Image Metrics Mimic Radiologists' Perception?
    Akasaka, Thai
    Fujimoto, Koji
    Yamamoto, Takayuki
    Okada, Tomohisa
    Fushumi, Yasutaka
    Yamamoto, Akira
    Tanaka, Toshiyuki
    Togashi, Kaori
    PLOS ONE, 2016, 11 (01):
  • [40] Rapid 2D phase-contrast magnetic resonance angiography reconstruction algorithm via compressed sensing
    Dong-Hoon Lee
    Cheol-Pyo Hong
    Man-Woo Lee
    Bong-Soo Han
    Journal of the Korean Physical Society, 2013, 63 : 1072 - 1076