Denoising parameter dependence of coronary artery depictability in compressed sensing magnetic resonance angiography

被引:0
|
作者
Takahashi, Junji [1 ,2 ]
Machida, Yoshio [2 ]
Fukuzawa, Kei [1 ]
Tsuji, Yoshinori [1 ]
Ohmoto-Sekine, Yuki [3 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol Technol, 2-2-2 Toranomon,Minato Ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Hlth Sci, 2-1 Seiryo Machi,Aoba Ku, Sendai, Miyagi 9808575, Japan
[3] Toranomon Gen Hosp, Hlth Management Ctr, 2-2-2 Toranomon,Minato-ku, Tokyo 1058470, Japan
关键词
Coronary magnetic resonance angiography; Image quality; Compressed sensing; Acceleration factor; Denoising factor; STATE FREE PRECESSION; PARTIALLY PARALLEL ACQUISITIONS; MR-ANGIOGRAPHY; RELAXATION; NOISE; TIME;
D O I
10.1007/s12194-024-00787-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Using numerical indices and visual evaluation, we evaluated the dependence of coronary-artery depictability on the denoising parameter in compressed sensing magnetic resonance angiography (CS-MRA). This study was conducted to clarify the acceleration factor (AF) and denoising factor (DF) dependence of CS-MRA image quality. Vascular phantoms and clinical images were acquired using three-dimensional CS-MRA on a clinical 1.5 T system. For the phantom measurements, we compared the full width at half maximum (FWHM), sharpness, and contrast ratio of the vascular profile curves for various AFs and DFs. In the clinical cases, the FWHM, sharpness, contrast ratio, signal-to-noise ratio, noise level values, and visual evaluation results were compared for various DFs. Phantom image analyses demonstrated that the respective measurements of the FWHM, sharpness, and contrast ratios did not significantly change with an increase in AF. The FWHM and sharpness measurements slightly changed with the DF level. However, the contrast ratio tended to increase with an increase in the DF level. In the clinical cases, the FWHM and sharpness showed no significant differences, even when the DF level was changed. However, the contrast ratio tended to decrease as the DF level increased. When the DF levels of the clinical cases increased, the background signals of the myocardium, fat, and noise levels decreased. We investigated the dependence of the coronary-artery depictability on AF and DF using CS-MRA. Analysis of the coronary-artery profile curves indicated that a better image quality was achieved with a stronger DF on coronary CS-MRA.
引用
收藏
页码:375 / 388
页数:14
相关论文
共 50 条
  • [21] Compressed Sensing 3-Dimensional Time-of-Flight Magnetic Resonance Angiography for Cerebral Aneurysms Optimization and Evaluation
    Fushimi, Yasutaka
    Fujimoto, Koji
    Okada, Tomohisa
    Yamamoto, Akira
    Tanaka, Toshiyuki
    Kikuchi, Takayuki
    Miyamoto, Susumu
    Togashi, Kaori
    INVESTIGATIVE RADIOLOGY, 2016, 51 (04) : 228 - 235
  • [22] Compressed sensing trends in magnetic resonance imaging
    Sandilya, Mrinmoy
    Nirmala, S. R.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2017, 20 (04): : 1342 - 1352
  • [23] Compressed Sensing Parallel Magnetic Resonance Imaging
    Ji, Jim X.
    Zhao, Chen
    Lang, Tao
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1671 - 1674
  • [24] A Compressed Sensing Framework for Magnetic Resonance Fingerprinting
    Davies, Mike
    Puy, Gilles
    Vandergheynst, Pierre
    Wiaux, Yves
    SIAM JOURNAL ON IMAGING SCIENCES, 2014, 7 (04): : 2623 - 2656
  • [25] Coronary Magnetic Resonance Angiography in Chronic Coronary Syndromes
    Hajhosseiny, Reza
    Munoz, Camila
    Cruz, Gastao
    Khamis, Ramzi
    Kim, Won Yong
    Prieto, Claudia
    Botnar, Rene M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [26] Clinical feasibility study of 3D intracranial magnetic resonance angiography using compressed sensing
    Lin, Zhiyong
    Zhang, Xiaodong
    Guo, Li
    Wang, Ke
    Jiang, Yuan
    Hu, Xiaoyu
    Huang, Yong
    Wei, Juan
    Ma, Shuai
    Liu, Yi
    Zhu, Lina
    Zhuo, Zhizheng
    Liu, Jing
    Wang, Xiaoying
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (06) : 1843 - 1851
  • [27] Assessment of coronary artery patency after stent placement using magnetic resonance angiography
    Duerinckx, AJ
    Atkinson, D
    Hurwitz, R
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 896 - 902
  • [28] Coronary artery angiography and myocardial viability imaging: a 3.0-T contrast-enhanced magnetic resonance coronary artery angiography with Gd-BOPTA
    Yun, Hong
    Jin, Hang
    Yang, Shan
    Huang, Dong
    Chen, Zhang-wei
    Zeng, Meng-su
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01): : 99 - 108
  • [29] Noninvasive Detection of Coronary Artery Stenoses with Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3.0 T
    Chen, Zhiyong
    Duan, Qing
    Xue, Xunjing
    Chen, Lianglong
    Ye, Wenbin
    Jin, Lixin
    Sun, Bin
    CARDIOLOGY, 2010, 117 (04) : 284 - 290
  • [30] Parallel Magnetic Resonance Imaging Using Compressed Sensing
    Bilgin, Ali
    Kim, Yookyung
    Lalgudi, Hariharan G.
    Trouard, Theodore P.
    Altbach, Maria I.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXI, 2008, 7073