Performance evaluation of a novel high-sensitivity cardiac troponin T assay: analytical and clinical perspectives

被引:2
|
作者
Li, Zhongxin [2 ]
Yang, Shuo [2 ]
Qiao, Jiao [2 ]
Tan, Yuan [2 ]
Liu, Qi [2 ]
Yang, Boxin [2 ]
Feng, Weimin [2 ]
Cui, Liyan [1 ]
机构
[1] Peking Univ Third Hosp, Dept Lab Med, 49 North Garden Rd, Beijing 100191, Peoples R China
[2] Peking Univ Third Hosp, Dept Lab Med, Beijing, Peoples R China
关键词
performance evaluation; high-sensitivity; cardiac troponin T; light-initiated chemiluminescent assay; RISK STRATIFICATION; IMMUNOASSAY;
D O I
10.1515/cclm-2023-0789
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To evaluate the analytical characteristics of a novel high-sensitivity cardiac troponin T (hs-cTnT) test on the automatic light-initiated chemiluminescent assay (LiCA (R)) system, and validated its diagnostic performance for non-ST-segment elevation myocardial infarction (NSTEMI).Methods: Studies included an extensive analytical evaluation and established the 99th percentile upper reference limit (URL) from apparently healthy individuals, followed by a diagnostic performance validation for NSTEMI.Results: Sex-specific 99th percentile URLs were 16.0 ng/L (1.7 % CV: coefficient of variation) for men (21-92 years) and 13.4 ng/L (2.0 % CV) for women (23-87 years) in serum, and 30.6 ng/L (0.9 % CV) for men (18-87 years) and 20.2 ng/L (1.4 % CV) for women (18-88 years) in heparin plasma. Detection rates in healthy individuals ranged from 98.9 to 100 %. An excellent agreement was identified between LiCA (R) and Elecsys (R) assays with a correlation coefficient of 0.993 and mean bias of -0.7 % (-1.8-0.4 %) across the full measuring range, while the correlation coefficient and overall bias were 0.967 and -1.1 % (-2.5-0.3 %) for the lower levels of cTnT (10-100 ng/L), respectively. At the specific medical decision levels (14.0 and 52.0 ng/L), assay difference was estimated to be <5.0 %. No significant difference was found between these two assays in terms of area under curve (AUC), sensitivity and specificity, negative predictive value (NPV) and positive predictive value (PPV) for the diagnosis of NSTEMI.Conclusions: LiCA (R) hs-cTnT is a reliable 3rd-generation (level 4) high-sensitivity assay for detecting cardiac troponin T. The assay is acceptable for practical use in the diagnosis of NSTEMI.
引用
收藏
页码:979 / 987
页数:9
相关论文
共 50 条
  • [31] Applying High-Sensitivity Cardiac Troponin T
    Glarner, Noemi
    Lopez-Ayala, Pedro
    Cakal, Hatice
    Grossenbacher, Mario
    Miro, Oscar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (18)
  • [32] Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
    Apple, Fred S.
    Collinson, Paul O.
    CLINICAL CHEMISTRY, 2012, 58 (01) : 54 - 61
  • [33] Diagnostic Reclassification by a High-Sensitivity Cardiac Troponin Assay
    Mumma, Bryn E.
    Casey, Scott D.
    Dang, Robert K.
    Polen, Michelle K.
    Kaur, Jasmanpreet C.
    Rodrigo, John
    Tancredi, Daniel J.
    Narverud, Robert A.
    Amsterdam, Ezra A.
    Tran, Nam
    ANNALS OF EMERGENCY MEDICINE, 2020, 76 (05) : 566 - 579
  • [34] Analytical characterization of the Siemens Dimension EXL high-sensitivity cardiac troponin I assay
    Kaysak, Peter A.
    MacCuish, Jackie
    Boreyko, Jill
    Roy, Chantele
    Lamers, Shana
    Clark, Lorna
    CLINICAL BIOCHEMISTRY, 2019, 69 : 52 - 56
  • [35] Dichotomizing High-Sensitivity Cardiac Troponin T Results and Important Analytical Considerations
    Kavsak, Peter A.
    Worster, Andrew
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (17) : 1570 - 1570
  • [36] Evaluation of High-Sensitivity Assays for Cardiac Troponin
    Morrow, David A.
    Antman, Elliott M.
    CLINICAL CHEMISTRY, 2009, 55 (01) : 5 - 8
  • [37] Clinical Impact of High-Sensitivity Cardiac Troponin T Implementation in the Community
    Ola, Olatunde
    Akula, Ashok
    De Michieli, Laura
    Dworak, Marshall
    Crockford, Erika
    Lobo, Ronstan
    Rastas, Nicholas
    Knott, Jonathan D.
    Mehta, Ramila A.
    Hodge, David O.
    Grube, Eric
    Karturi, Swetha
    Wohlrab, Scott
    Tak, Tahir
    Cagin, Charles
    Gulati, Rajiv
    Jaffe, Allan S.
    Sandoval, Yader
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (25) : 3160 - 3170
  • [38] Validation of Analytical Performance Limits for Accuracy with High-Sensitivity Cardiac Troponin Assays
    Kavsak, Peter A.
    Kumaritakis, Alexander
    Wong-Fung, Matthew
    Badrick, Tony
    Knauer, Michael
    CLINICAL CHEMISTRY, 2024, 71 (02) : 332 - 334
  • [39] High diagnostic performance of a high-sensitivity cardiac troponin T assay in patients with suspected acute coronary syndrome
    Zuily, Stephane
    Chenevier-Gobeaux, Camille
    Claessens, Yann-Eric
    Wahbi, Karim
    Weber, Simon
    Meune, Christophe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 146 (01) : 115 - 116
  • [40] Analytical factors to consider when assessing a high-sensitivity cardiac troponin I assay compared to a contemporary assay in clinical studies
    Rezvanpour, Atoosa
    Shortt, Colleen
    Clark, Lorna
    Worster, Andrew
    Kavsak, Peter A.
    CLINICA CHIMICA ACTA, 2014, 429 : 6 - 7