Volumetric Absorptive Microsampling in the Analysis of Endogenous Metabolites

被引:8
|
作者
de Sa e Silva, Daniel Marques [1 ,2 ]
Thaitumu, Marlene [2 ,3 ]
Theodoridis, Georgios [1 ,2 ]
Witting, Michael [4 ,5 ]
Gika, Helen [2 ,3 ]
机构
[1] Aristotle Univ Thessaloniki AUTH, Dept Chem, Thessaloniki 54124, Greece
[2] Ctr Interdisciplinary Res & Innovat CIRI AUTH, Biomic AUTh, Balkan Ctr B1 4, GR-57001 Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Sch Med, Thessaloniki 54124, Greece
[4] Helmholtz Zentrum Munchen, Metab & Proteom Core, Ingolstadter Land Str 1, D-85764 Neuherberg, Germany
[5] Tech Univ Munich, TUM Sch Life Sci, Chair Analyt Food Chem, Maximus von Imhof Forum 6, D-85354 Freising Weihenstephan, Germany
基金
欧盟地平线“2020”;
关键词
volumetric absorptive microsampling (VAMS); blood microsampling; endogenous metabolites; biomarkers; analytical validation; clinical application; WHOLE-BLOOD; QUANTITATIVE BIOANALYSIS; LC-MS/MS; THIAMINE STATUS; HEMATOCRIT; DEVICES; PLASMA; VAMS; QUANTIFICATION; VALIDATION;
D O I
10.3390/metabo13101038
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric absorptive microsampling (VAMS) has arisen as a relevant tool in biological analysis, offering simplified sampling procedures and enhanced stability. Most of the attention VAMS has received in the past decade has been from pharmaceutical research, with most of the published work employing VAMS targeting drugs or other exogenous compounds, such as toxins and pollutants. However, biomarker analysis by employing blood microsampling has high promise. Herein, a comprehensive review on the applicability of VAMS devices for the analysis of endogenous metabolites/biomarkers was performed. The study presents a full overview of the analysis process, incorporating all the steps in sample treatment and validation parameters. Overall, VAMS devices have proven to be reliable tools for the analysis of endogenous analytes with biological importance, often offering improved analyte stability in comparison with blood under ambient conditions as well as a convenient and straightforward sample acquisition model.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] A volumetric absorptive microsampling LC-MS/MS method for five immunosuppressants and their hematocrit effects
    Koster, Remco A.
    Niemeijer, Pascal
    Veenhof, Herman
    van Hateren, Kai
    Alffenaar, Jan-Willem C.
    Touw, Daan J.
    BIOANALYSIS, 2019, 11 (06) : 495 - 508
  • [32] Volumetric Absorptive Microsampling as a New Biosampling Tool for Monitoring of Tamoxifen, Endoxifen, 4-OH Tamoxifen and N-Desmethyltamoxifen in Breast Cancer Patients
    Maggadani, Baitha Palanggatan
    Harmita
    Haryono, Samuel J.
    Rinaldi, Marcellino Ryan
    Harahap, Yahdiana
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2021, 15 : 2417 - 2430
  • [33] Volumetric absorptive microsampling: its use in COVID-19 research and testing
    Rudge, James
    Kushon, Stuart
    BIOANALYSIS, 2021, 13 (24) : 1851 - 1863
  • [34] Validation of methods for determining pediatric midazolam using wet whole blood and volumetric absorptive microsampling
    Abu-Rabie, Paul
    Neupane, Bikalpa
    Spooner, Neil
    Rudge, James
    Denniff, Philip
    Mulla, Hussain
    Pandya, Hitesh
    BIOANALYSIS, 2019, 11 (19) : 1737 - 1754
  • [35] Mercury biomonitoring in German adults using volumetric absorptive microsampling
    Anastasia Koutsimpani-Wagner
    Caroline Quartucci
    James P. K. Rooney
    Stephan Bose-O’Reilly
    Stefan Rakete
    Environmental Monitoring and Assessment, 2022, 194
  • [36] Next generation microsampling towards sustainable forensic analysis: Volumetric DBS for cocaine and metabolites
    Palano, Sarah
    Turonova, Dorota
    Protti, Michele
    Krcmova, Lenka Kujovska
    Sardella, Roccaldo
    Mladenka, Premysl
    Mandrioli, Roberto
    Girotti, Stefano
    Mercolini, Laura
    MICROCHEMICAL JOURNAL, 2024, 203
  • [37] Quantitative bioanalytical validation of fosfomycin in human whole blood with volumetric absorptive microsampling
    Parker, Suzanne L.
    Roberts, Jason A.
    Lipman, Jeffrey
    Wallis, Steven C.
    BIOANALYSIS, 2015, 7 (19) : 2585 - 2595
  • [38] Validation and clinical application of a volumetric absorptive microsampling method for 14 psychiatric drugs
    Stern, Mike
    Giebels, Melanie
    Fey, Tilman
    Lubking, Margit
    Alferink, Judith
    Hempel, Georg
    BIOANALYSIS, 2020, 12 (16) : 1129 - 1147
  • [39] Mercury biomonitoring in German adults using volumetric absorptive microsampling
    Koutsimpani-Wagner, Anastasia
    Quartucci, Caroline
    Rooney, James P. K.
    Bose-O'Reilly, Stephan
    Rakete, Stefan
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (04)
  • [40] Analytical Validation of a Volumetric Absorptive Microsampling Method for Therapeutic Drug Monitoring of the Oral Targeted Anticancer Agents, Abiraterone, Alectinib, Cabozantinib, Imatinib, Olaparib, and Sunitinib, and Metabolites
    Meertens, Marinda
    de Vries, Niels
    Rosing, Hilde
    Steeghs, Neeltje
    Beijnen, Jos H.
    Huitema, Alwin D. R.
    THERAPEUTIC DRUG MONITORING, 2024, 46 (04) : 494 - 502