Volumetric Absorptive Microsampling in the Analysis of Endogenous Metabolites

被引:8
|
作者
de Sa e Silva, Daniel Marques [1 ,2 ]
Thaitumu, Marlene [2 ,3 ]
Theodoridis, Georgios [1 ,2 ]
Witting, Michael [4 ,5 ]
Gika, Helen [2 ,3 ]
机构
[1] Aristotle Univ Thessaloniki AUTH, Dept Chem, Thessaloniki 54124, Greece
[2] Ctr Interdisciplinary Res & Innovat CIRI AUTH, Biomic AUTh, Balkan Ctr B1 4, GR-57001 Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Sch Med, Thessaloniki 54124, Greece
[4] Helmholtz Zentrum Munchen, Metab & Proteom Core, Ingolstadter Land Str 1, D-85764 Neuherberg, Germany
[5] Tech Univ Munich, TUM Sch Life Sci, Chair Analyt Food Chem, Maximus von Imhof Forum 6, D-85354 Freising Weihenstephan, Germany
基金
欧盟地平线“2020”;
关键词
volumetric absorptive microsampling (VAMS); blood microsampling; endogenous metabolites; biomarkers; analytical validation; clinical application; WHOLE-BLOOD; QUANTITATIVE BIOANALYSIS; LC-MS/MS; THIAMINE STATUS; HEMATOCRIT; DEVICES; PLASMA; VAMS; QUANTIFICATION; VALIDATION;
D O I
10.3390/metabo13101038
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric absorptive microsampling (VAMS) has arisen as a relevant tool in biological analysis, offering simplified sampling procedures and enhanced stability. Most of the attention VAMS has received in the past decade has been from pharmaceutical research, with most of the published work employing VAMS targeting drugs or other exogenous compounds, such as toxins and pollutants. However, biomarker analysis by employing blood microsampling has high promise. Herein, a comprehensive review on the applicability of VAMS devices for the analysis of endogenous metabolites/biomarkers was performed. The study presents a full overview of the analysis process, incorporating all the steps in sample treatment and validation parameters. Overall, VAMS devices have proven to be reliable tools for the analysis of endogenous analytes with biological importance, often offering improved analyte stability in comparison with blood under ambient conditions as well as a convenient and straightforward sample acquisition model.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Volumetric Absorptive Microsampling in Toxicology
    Pires, Bruno
    Catarro, Goncalo
    Soares, Sofia
    Goncalves, Joana
    Rosado, Tiago
    Barroso, Mario
    Araujo, Andre R. T. S.
    Gallardo, Eugenia
    TOXICS, 2025, 13 (01)
  • [2] Tutorial: Volumetric absorptive microsampling (VAMS)
    Protti, Michele
    Mandrioli, Roberto
    Mercolini, Laura
    ANALYTICA CHIMICA ACTA, 2019, 1046 : 32 - 47
  • [3] LC-MS/MS measurement of endogenous steroid hormones and phase II metabolites in blood volumetric absorptive microsampling (VAMS) for doping control purposes
    Ponzetto, Federico
    Parasiliti-Caprino, Mirko
    Leoni, Laura
    Marinelli, Lorenzo
    Nonnato, Antonello
    Nicoli, Raul
    Kuuranne, Tiia
    Ghigo, Ezio
    Mengozzi, Giulio
    Settanni, Fabio
    CLINICA CHIMICA ACTA, 2024, 557
  • [4] Applications of Volumetric Absorptive Microsampling Technique: A Systematic Critical Review
    Dodeja, Prerna
    Giannoutsos, Spiros
    Caritis, Steve
    Venkataramanan, Raman
    THERAPEUTIC DRUG MONITORING, 2023, 45 (04) : 431 - 462
  • [5] Volumetric absorptive microsampling: Current advances and applications
    Kok, Miranda G. M.
    Fillet, Marianne
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 147 : 288 - 296
  • [6] Volumetric Absorptive Microsampling as a Sampling Alternative in Clinical Trials and Therapeutic Drug Monitoring During the COVID-19 Pandemic: A Review
    Harahap, Yahdiana
    Diptasaadya, Rasmina
    Purwanto, Denni Joko
    DRUG DESIGN DEVELOPMENT AND THERAPY, 2020, 14 : 5757 - 5771
  • [7] Capillary blood collected on volumetric absorptive microsampling (VAMS) device for monitoring hydroxychloroquine in rheumatoid arthritis patients
    Qu, Ying
    Brady, Kelley
    Apilado, Robert
    O'Malley, Tyler
    Reddy, Smitha
    Chitkara, Puja
    Ibarra, Claudia
    Alexander, Roberta Vezza
    Dervieux, Thierry
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 140 : 334 - 341
  • [8] Volumetric absorptive microsampling-LC-MS/MS assays for quantitation of giredestrant in dried human whole blood
    Johnson, Ryan
    Rehmani, Imran
    Leahy, Mark
    Walker, Abigail
    Liang, Xiaorong
    Dean, Brian
    Wang, Jianshuang
    BIOANALYSIS, 2022, 14 (21) : 1377 - 1389
  • [9] Drug monitoring by volumetric absorptive microsampling: method development considerations to mitigate hematocrit effects
    Fang, Kasie
    Bowen, Chester L.
    Kellie, John F.
    Karlinsey, Molly Z.
    Evans, Christopher A.
    BIOANALYSIS, 2018, 10 (04) : 241 - 255
  • [10] Analysis of tamoxifen and its metabolites in dried blood spot and volumetric absorptive microsampling: comparison and clinical application
    Maggadani, Baitha Palanggatan
    Harahap, Yahdiana
    Harmita
    Haryono, Samuel J.
    Untu, Christoffel William Putra
    HELIYON, 2021, 7 (06)