Volumetric Absorptive Microsampling in the Analysis of Endogenous Metabolites

被引:9
作者
de Sa e Silva, Daniel Marques [1 ,2 ]
Thaitumu, Marlene [2 ,3 ]
Theodoridis, Georgios [1 ,2 ]
Witting, Michael [4 ,5 ]
Gika, Helen [2 ,3 ]
机构
[1] Aristotle Univ Thessaloniki AUTH, Dept Chem, Thessaloniki 54124, Greece
[2] Ctr Interdisciplinary Res & Innovat CIRI AUTH, Biomic AUTh, Balkan Ctr B1 4, GR-57001 Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Sch Med, Thessaloniki 54124, Greece
[4] Helmholtz Zentrum Munchen, Metab & Proteom Core, Ingolstadter Land Str 1, D-85764 Neuherberg, Germany
[5] Tech Univ Munich, TUM Sch Life Sci, Chair Analyt Food Chem, Maximus von Imhof Forum 6, D-85354 Freising Weihenstephan, Germany
基金
欧盟地平线“2020”;
关键词
volumetric absorptive microsampling (VAMS); blood microsampling; endogenous metabolites; biomarkers; analytical validation; clinical application; WHOLE-BLOOD; QUANTITATIVE BIOANALYSIS; LC-MS/MS; THIAMINE STATUS; HEMATOCRIT; DEVICES; PLASMA; VAMS; QUANTIFICATION; VALIDATION;
D O I
10.3390/metabo13101038
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Volumetric absorptive microsampling (VAMS) has arisen as a relevant tool in biological analysis, offering simplified sampling procedures and enhanced stability. Most of the attention VAMS has received in the past decade has been from pharmaceutical research, with most of the published work employing VAMS targeting drugs or other exogenous compounds, such as toxins and pollutants. However, biomarker analysis by employing blood microsampling has high promise. Herein, a comprehensive review on the applicability of VAMS devices for the analysis of endogenous metabolites/biomarkers was performed. The study presents a full overview of the analysis process, incorporating all the steps in sample treatment and validation parameters. Overall, VAMS devices have proven to be reliable tools for the analysis of endogenous analytes with biological importance, often offering improved analyte stability in comparison with blood under ambient conditions as well as a convenient and straightforward sample acquisition model.
引用
收藏
页数:24
相关论文
共 54 条
[1]   Simultaneous determination of vancomycin and creatinine in plasma applied to volumetric absorptive microsampling devices using liquid chromatography-tandem mass spectrometry [J].
Andriguetti, Nadine B. ;
Lisboa, Leticia L. ;
Hahn, Siomara R. ;
Pagnussat, Lidiane R. ;
Antunes, Marina, V ;
Linden, Rafael .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 :315-324
[2]   The health effects of vitamin D supplementation: evidence from human studies [J].
Bouillon, Roger ;
Manousaki, Despoina ;
Rosen, Cliff ;
Trajanoska, Katerina ;
Rivadeneira, Fernando ;
Richards, J. Brent .
NATURE REVIEWS ENDOCRINOLOGY, 2022, 18 (02) :96-110
[3]   Evaluation of volumetric blood collection devices for the measurement of phenylalanine and tyrosine to monitor patients with phenylketonuria [J].
Carling, Rachel S. ;
Emmett, Erin C. ;
Moat, Stuart J. .
CLINICA CHIMICA ACTA, 2022, 535 :157-166
[4]   Determination of anabolic steroids in dried blood using microsampling and gas chromatography-tandem mass spectrometry: Application to a testosterone gel administration study [J].
Chang, William Chih-Wei ;
Cowan, David A. ;
Walker, Christopher J. ;
Wojek, Nick ;
Brailsford, Alan D. .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1628
[5]   Does volumetric absorptive microsampling eliminate the hematocrit bias for caffeine and paraxanthine in dried blood samples? A comparative study [J].
De Kesel, Pieter M. M. ;
Lambert, Willy E. ;
Stove, Christophe P. .
ANALYTICA CHIMICA ACTA, 2015, 881 :65-73
[6]   Quantitative bioanalysis of paracetamol in rats using volumetric absorptive microsampling (VAMS) [J].
Denniff, Philip ;
Parry, Simon ;
Dopson, Wesley ;
Spooner, Neil .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 108 :61-69
[7]   Volumetric Absorptive Microsampling: A Dried Sample Collection Technique for Quantitative Bioanalysis [J].
Denniff, Philip ;
Spooner, Neil .
ANALYTICAL CHEMISTRY, 2014, 86 (16) :8489-8495
[8]   The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs [J].
Denniff, Philip ;
Spooner, Neil .
BIOANALYSIS, 2010, 2 (08) :1385-1395
[9]   Applications of Volumetric Absorptive Microsampling Technique: A Systematic Critical Review [J].
Dodeja, Prerna ;
Giannoutsos, Spiros ;
Caritis, Steve ;
Venkataramanan, Raman .
THERAPEUTIC DRUG MONITORING, 2023, 45 (04) :431-462
[10]   Combined quantification of corticotropin-releasing hormone, cortisol-to-cortisone ratio and progesterone by liquid chromatography-Tandem mass spectrometry in placental tissue [J].
Fahlbusch, Fabian B. ;
Ruebner, Matthias ;
Rascher, Wolfgang ;
Rauh, Manfred .
STEROIDS, 2013, 78 (09) :888-895