Detection of Low Blood Hemoglobin Levels on Pulmonary CT Angiography: A Feasibility Study Combining Dual-Energy CT and Machine Learning

被引:0
|
作者
Kay, Fernando U. [1 ]
Lumby, Cynthia [2 ]
Tanabe, Yuki [3 ]
Abbara, Suhny [1 ]
Rajiah, Prabhakar [4 ]
机构
[1] Univ Texas Southwestern Med Ctr, Dept Radiol, Dallas, TX 75390 USA
[2] Vet Affairs North Texas Hlth Care Syst, Dallas, TX 75216 USA
[3] Ehime Univ, Dept Radiol, Matsuyama 7900825, Japan
[4] Mayo Clin, Dept Radiol, Rochester, MN 55901 USA
关键词
anemia; pulmonary embolism; computed tomography angiography; machine learning; VIRTUAL NON-CONTRAST; COMPUTED-TOMOGRAPHY; ANEMIA; OUTCOMES; PREVALENCE; ATTENUATION; DIAGNOSIS; REPAIR;
D O I
10.3390/tomography9040123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To evaluate if dual-energy CT (DECT) pulmonary angiography (CTPA) can detect anemia with the aid of machine learning. Methods: Inclusion of 100 patients (mean age +/- SD, 51.3 +/- 14.8 years; male-to-female ratio, 42/58) who underwent DECT CTPA and hemoglobin (Hb) analysis within 24 h, including 50 cases with Hb below and 50 controls with Hb >= 12 g/dL. Blood pool attenuation was assessed on virtual noncontrast (VNC) images at eight locations. A classification model using extreme gradient-boosted trees was developed on a training set (n = 76) for differentiating cases from controls. The best model was evaluated in a separate test set (n = 24). Results: Blood pool attenuation was significantly lower in cases than controls (p-values < 0.01), except in the right atrium (p = 0.06). The machine learning model had sensitivity, specificity, and accuracy of 83%, 92%, and 88%, respectively. Measurements at the descending aorta had the highest relative importance among all features; a threshold of 43 HU yielded sensitivity, specificity, and accuracy of 68%, 76%, and 72%, respectively. Conclusion: VNC imaging and machine learning shows good diagnostic performance for detecting anemia on DECT CTPA.
引用
收藏
页码:1538 / 1550
页数:13
相关论文
共 50 条
  • [1] Dual-energy CT arthrography: a feasibility study
    Sandhu, Rashpal
    Aslan, Mercan
    Obuchowski, Nancy
    Primak, Andrew
    Karim, Wadih
    Subhas, Naveen
    SKELETAL RADIOLOGY, 2021, 50 (04) : 693 - 703
  • [2] Dual-Energy CT Angiography for Detection of Pulmonary Emboli: Incremental Benefit of Iodine Maps
    Weidman, Elizabeth K.
    Plodkowski, Andrew J.
    Halpenny, Darragh F.
    Hayes, Sara A.
    Perez-Johnston, Rocio
    Zheng, Junting
    Moskowitz, Chava
    Ginsberg, Michelle S.
    RADIOLOGY, 2018, 289 (02) : 546 - 553
  • [3] Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography
    Lee, Choong Wook
    Seo, Joon Beom
    Song, Jae-Woo
    Kim, Mi-Young
    Lee, Ha Young
    Park, Yang Shin
    Chae, Eun Jin
    Jang, Yu Mi
    Kim, Namkug
    Krauss, Bernard
    EUROPEAN RADIOLOGY, 2011, 21 (01) : 54 - 62
  • [4] Evaluation of computer-aided detection and dual energy software in detection of peripheral pulmonary embolism on dual-energy pulmonary CT angiography
    Choong Wook Lee
    Joon Beom Seo
    Jae-Woo Song
    Mi-Young Kim
    Ha Young Lee
    Yang Shin Park
    Eun Jin Chae
    Yu Mi Jang
    Namkug Kim
    Bernard Krauss
    European Radiology, 2011, 21 : 54 - 62
  • [5] Dual-energy CT arthrography: a feasibility study
    Rashpal Sandhu
    Mercan Aslan
    Nancy Obuchowski
    Andrew Primak
    Wadih Karim
    Naveen Subhas
    Skeletal Radiology, 2021, 50 : 693 - 703
  • [6] Dual-energy MDCT: Comparison of pulmonary artery enhancement on dedicated CT pulmonary angiography, routine and low contrast volume studies
    Godoy, Myrna C. B.
    Heller, Samantha L.
    Naidich, David P.
    Assadourian, Bernard
    Leidecker, Christianne
    Schmidt, Bernhard
    Vlahos, Ioannis
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E11 - E17
  • [7] Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT
    Bauer, Ralf W.
    Kramer, Sebastian
    Renker, Matthias
    Schell, Boris
    Larson, Maya Christina
    Beeres, Martin
    Lehnert, Thomas
    Jacobi, Volkmar
    Vogl, Thomas J.
    Kerl, Josef Matthias
    EUROPEAN RADIOLOGY, 2011, 21 (10) : 2139 - 2147
  • [8] Machine learning-based dual-energy CT parametric mapping
    Su, Kuan-Hao
    Kuo, Jung-Wen
    Jordan, David W.
    Van Hedent, Steven
    Klahr, Paul
    Wei, Zhouping
    Al Helo, Rose
    Liang, Fan
    Qian, Pengjiang
    Pereira, Gisele C.
    Rassouli, Negin
    Gilkeson, Robert C.
    Traughber, Bryan J.
    Cheng, Chee-Wai
    Muzic, Raymond F., Jr.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (12):
  • [9] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Giovanni Foti
    Ronaldo Silva
    Niccolò Faccioli
    Alessandro Fighera
    Rossella Menghini
    Arianna Campagnola
    Giovanni Carbognin
    European Radiology, 2021, 31 : 1923 - 1931
  • [10] Identification of pulmonary embolism: diagnostic accuracy of venous-phase dual-energy CT in comparison to pulmonary arteries CT angiography
    Foti, Giovanni
    Silva, Ronaldo
    Faccioli, Niccolo
    Fighera, Alessandro
    Menghini, Rossella
    Campagnola, Arianna
    Carbognin, Giovanni
    EUROPEAN RADIOLOGY, 2021, 31 (04) : 1923 - 1931