Role of doppler ultrasound in detecting vascular complications in recipients of living donor liver transplant (LDLT)

被引:1
|
作者
Hussain, Huma [1 ]
Rafique, Muhammad Salman [1 ]
Kundi, Sana [1 ]
Malik, Tahir [1 ]
Din, Ahmad Zia Ud [1 ]
Saeed, Abdullah [1 ]
机构
[1] Pakistan Kidney & Liver Inst & Res Ctr, Dept Radiol, Lahore, Pakistan
关键词
CLD; Doppler US; Vascular complications; LDLT recipients; CECT abdomen; HEPATIC-ARTERY STENOSIS; RIGHT LOBE GRAFT; OUTFLOW OBSTRUCTION; ULTRASONOGRAPHY; SONOGRAPHY; THROMBOSIS;
D O I
10.47391/JPMA.6952
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the role of Doppler ultrasound in the detection of vascular complications in recipients of living donor liver transplant, keeping contrast-enhanced computerised tomography of abdomen as the gold standard. Method: The retrospective study was conducted from February 16 to April 1, 2022, at the Pakistan Kidney and Liver Institute and Research Centre, Lahore, Pakistan, and comprised data of living donor liver transplant recipients who had undergone contrast-enhanced computerised tomography of abdomen within 24 hours of Doppler ultrasound between January 2021 and January 2022. For the diagnosis of hepatic vascular complications, the diagnostic values of Doppler ultrasound parameters were derived by correlating Doppler ultrasound findings with contrast-enhanced computerised tomography results. Data was analysed using SPSS 20. Results: Of the 35 patients, 24(68.6%) were men and 11(31.4%) were women. The overall mean age was 45.86 +/- 13.8 years. For hepatic artery thrombosis, the use of Doppler ultrasound criteria yielded a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 100%, 96.6%, 83.3%, 100%, and 97.1% respectively. For hepatic artery stenosis, overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Doppler ultrasound was 100%, 96.8%, 75%, 100% and 97.1% respectively. Doppler ultrasound parameters resulted in a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 100% each in detecting portal vein and hepatic venous outflow tract thrombosis. Overall, Doppler ultrasound sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy was found to be 100%, 88.8%, 89.4%, 100% and 94.2% respectively. Conclusion: Doppler ultrasound was adequate to document vascular complications after living donor liver transplant in majority of the cases with high accuracy and sensitivity.
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 50 条
  • [41] Vascular complications in liver transplantation: Beneficial role of contrast-enhanced ultrasound (CEUS) in the postoperative phase
    Ruebenthaler, J.
    Paprottka, K. J.
    Hameister, E.
    Hoffmann, K.
    Joiko, N.
    Reiser, M.
    Clevert, D. A.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2016, 64 (03) : 475 - 482
  • [42] Doppler ultrasound follow-up of middle hepatic vein tributaries-interposition vessel graft in recipients of living donor liver transplantation using modified right lobe grafts
    Lee, Sunyoung
    Kim, Kyoung Won
    Jeong, So Yeong
    Lee, Kyung Jin
    Kim, So Yeon
    Song, Gi Won
    Lee, Sung Gyu
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1089)
  • [43] Outcomes of Right and Left Hepatic Arterial Anastomosis in Right Lobe Living Donor Liver Transplant
    Chikkala, Bhargava Ram
    Rahul
    Agarwal, Shaleen
    Vijayashanker, Aarathi
    Pandey, Yuktansh
    Balradja, Inbaraj
    Dey, Rajesh
    Gupta, Subhash
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2022, 20 (02) : 157 - 163
  • [44] THE ROLE OF ENDOVASCULAR AND ENDOBILIARY METHODS IN THE TREATMENT OF POST-LIVER TRANSPLANT COMPLICATIONS
    Gautier, S., V
    Voskanov, M. A.
    Monakhov, A. R.
    Semash, K. O.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2020, 22 (04): : 140 - 148
  • [45] Frequency and Outcome of Hepatic Arterial Thrombosis in Recipients of Living Donor Liver Transplantation
    Ullah, Kaleem
    Dogar, Abdul Wahab
    Uddin, Shams
    Hasnain, Syed
    Ahmad, Bilal
    Ghaffar, Abdul
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (08): : 897 - 902
  • [46] Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas Grafts
    Swensson, Jordan
    Hill, Danielle
    Tirkes, Temel
    Fridell, Jonathan
    Patel, Aashish
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (05) : 1093 - 1097
  • [47] Doppler evaluation of hepatic hemodynamics after living donor liver transplantation in infants
    Chen, Xiping
    Xiao, Huan
    Yang, Chunjiang
    Chen, Jingyu
    Gao, Yang
    Tang, Yi
    Ji, Xiaojuan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [48] Prognostic value of ultrasound in early arterial complications post liver transplant
    Zhao, Ning-Bo
    Chen, Yi
    Xia, Rui
    Tang, Jian-Bo
    Zhao, Dong
    WORLD JOURNAL OF GASTROINTESTINAL SURGERY, 2024, 16 (01): : 13 - 20
  • [49] Meta-analysis of the diagnostic value of contrast-enhanced ultrasound for the detection of vascular complications after liver transplantation
    Chen, Suxian
    Wang, Xiong
    Zhang, Baoxin
    Liu, Beijing
    Pan, Hui
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2019, 111 (05) : 388 - 396
  • [50] Prevalence, presentation, and endovascular management of hemodynamically or clinically significant arterio-portal fistulae in living and cadaveric donor liver transplant recipients
    Saad, Wael
    Lippert, Allison
    Davies, Mark
    Arslan, Bulent
    Kumer, Sean
    Waldman, David
    Turba, Ulku
    Schmitt, Timothy
    Matsumoto, Alan
    Angle, John
    CLINICAL TRANSPLANTATION, 2012, 26 (04) : 532 - 538