Role of doppler ultrasound in detecting vascular complications in recipients of living donor liver transplant (LDLT)

被引:1
|
作者
Hussain, Huma [1 ]
Rafique, Muhammad Salman [1 ]
Kundi, Sana [1 ]
Malik, Tahir [1 ]
Din, Ahmad Zia Ud [1 ]
Saeed, Abdullah [1 ]
机构
[1] Pakistan Kidney & Liver Inst & Res Ctr, Dept Radiol, Lahore, Pakistan
关键词
CLD; Doppler US; Vascular complications; LDLT recipients; CECT abdomen; HEPATIC-ARTERY STENOSIS; RIGHT LOBE GRAFT; OUTFLOW OBSTRUCTION; ULTRASONOGRAPHY; SONOGRAPHY; THROMBOSIS;
D O I
10.47391/JPMA.6952
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the role of Doppler ultrasound in the detection of vascular complications in recipients of living donor liver transplant, keeping contrast-enhanced computerised tomography of abdomen as the gold standard. Method: The retrospective study was conducted from February 16 to April 1, 2022, at the Pakistan Kidney and Liver Institute and Research Centre, Lahore, Pakistan, and comprised data of living donor liver transplant recipients who had undergone contrast-enhanced computerised tomography of abdomen within 24 hours of Doppler ultrasound between January 2021 and January 2022. For the diagnosis of hepatic vascular complications, the diagnostic values of Doppler ultrasound parameters were derived by correlating Doppler ultrasound findings with contrast-enhanced computerised tomography results. Data was analysed using SPSS 20. Results: Of the 35 patients, 24(68.6%) were men and 11(31.4%) were women. The overall mean age was 45.86 +/- 13.8 years. For hepatic artery thrombosis, the use of Doppler ultrasound criteria yielded a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 100%, 96.6%, 83.3%, 100%, and 97.1% respectively. For hepatic artery stenosis, overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Doppler ultrasound was 100%, 96.8%, 75%, 100% and 97.1% respectively. Doppler ultrasound parameters resulted in a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 100% each in detecting portal vein and hepatic venous outflow tract thrombosis. Overall, Doppler ultrasound sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy was found to be 100%, 88.8%, 89.4%, 100% and 94.2% respectively. Conclusion: Doppler ultrasound was adequate to document vascular complications after living donor liver transplant in majority of the cases with high accuracy and sensitivity.
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 50 条
  • [31] Vascular complications after liver transplantation: evaluation with Doppler US
    Tamsel, Sadik
    Demirpolat, Gulgun
    Killi, Refik
    Aydin, Unal
    Kilic, Murat
    Zeytunlu, Murat
    Parildar, Mustafa
    Oran, Ismail
    Ucar, Hakan
    ABDOMINAL IMAGING, 2007, 32 (03): : 339 - 347
  • [32] Doppler Ultrasound of Vascular Complications After Pediatric Liver Transplantation: Incidence, Time of Detection, and Positive Predictive Value
    Verhagen, Martijn V. V.
    de Kleine, Ruben H. J.
    van der Doef, Hubert P. J.
    Kwee, Thomas C. C.
    de Haas, Robbert J. J.
    ULTRASOUND INTERNATIONAL OPEN, 2022, 08 (02) : E36 - E42
  • [33] Biliary Complications in 108 Consecutive Recipients With Duct-to-Duct Biliary Reconstruction in Living-Donor Liver Transplantation
    Mizuno, S.
    Inoue, H.
    Tanemura, A.
    Murata, Y.
    Kuriyama, N.
    Azumi, Y.
    Kishiwada, M.
    Usui, M.
    Sakurai, H.
    Tabata, M.
    Yamada, R.
    Yamamoto, N.
    Sugimoto, K.
    Shiraki, K.
    Takei, Y.
    Isaji, S.
    TRANSPLANTATION PROCEEDINGS, 2014, 46 (03) : 850 - 855
  • [34] Long-term Clinical Outcomes and Predictive Factors for Living-donor Liver Transplant Recipients With Biliary Strictures
    Han, Ji Won
    Choi, Jong Young
    Lee, Soon Kyu
    Sung, Pil Soo
    Jang, Jeong Won
    Yoon, Seung Kew
    Choi, Young Hoon
    Lee, In Seok
    Oh, Jung Suk
    Chun, Ho Jong
    Choi, Ho Joong
    You, Young Kyoung
    TRANSPLANTATION, 2022, 106 (10) : 1990 - 1999
  • [35] Comparison of vascular complications between external iliac and internal iliac artery anastomosis of the donor renal artery in renal transplant recipients
    Kumar, G. Manoj
    Ashok, Sunil
    Kumar, J. Suresh
    UROLOGY ANNALS, 2025, 17 (01) : 38 - 42
  • [36] Use of Intraoperative Duplex Ultrasound and Resistance Index Reduces Complications in Living Renal Donor Transplantation
    Bejic, M.
    Deglise, S.
    Venetz, J. P.
    Nseir, G.
    Dubuis, C.
    Saucy, F.
    Berard, X.
    Meuwly, J. Y.
    Corpataux, J. M.
    TRANSPLANTATION PROCEEDINGS, 2018, 50 (10) : 3192 - 3198
  • [37] Outcomes in Adult Liver Transplant Recipients Using Pediatric Deceased Donor Liver Grafts
    Vargas, Paola A.
    Wang, Haowei
    Dalzell, Christina
    Argo, Curtis
    Henry, Zachary
    Su, Feng
    Stotts, Matthew J.
    Northup, Patrick
    Oberholzer, Jose
    Pelletier, Shawn
    Goldaracena, Nicolas
    TRANSPLANTATION DIRECT, 2022, 8 (05): : E1315
  • [38] Role for contrast-enhanced ultrasound in assessing complications after kidney transplant
    Como, Giuseppe
    Da Re, Jacopo
    Adani, Gian Luigi
    Zuiani, Chiara
    Girometti, Rossano
    WORLD JOURNAL OF RADIOLOGY, 2020, 12 (08): : 156 - 171
  • [39] The Yield of Routine Post-Operative Doppler Ultrasound to Detect Early Post-Liver Transplantation Vascular Complications
    Minciuna, Iulia
    den Hoed, Caroline
    van der Meer, Adriaan J.
    Sonneveld, Milan J.
    Sprengers, Dave
    de Knegt, Robert J.
    de Jonge, Jeroen
    Maan, Raoel
    Polak, Wojciech G.
    Murad, Sarwa Darwish
    TRANSPLANT INTERNATIONAL, 2023, 36
  • [40] Increased risk of vascular thrombosis in pediatric liver transplant recipients with thrombophilia
    Cha, David J.
    Alfrey, Edward J.
    Desai, Dev M.
    MacConmara, Malcolm
    Hwang, Christine S.
    JOURNAL OF SURGICAL RESEARCH, 2015, 199 (02) : 671 - 675