Evaluation of the mechanical properties of current biliary self- expandable metallic stents: axial and radial force, and axial force zero border

被引:12
|
作者
Yamagata, Wataru [1 ]
Fujisawa, Toshio [1 ]
Sasaki, Takashi [2 ]
Ishibashi, Rei [3 ]
Saito, Tomotaka [3 ]
Yoshida, Shuntaro [4 ]
No, Shizuka [5 ]
Inoue, Kouta [5 ]
Nakai, Yousuke [3 ]
Sasahira, Naoki [2 ]
Isayama, Hiroyuki [1 ,6 ]
机构
[1] Juntendo Univ, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[2] Japanese Fdn Canc Res, Dept Hepatobiliary Pancreat Med, Canc Inst Hosp, Tokyo, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Gastroenterol, Tokyo, Japan
[4] Univ Tokyo, Grad Sch Med, Dept Endoscopy & Endoscop Surg, Tokyo, Japan
[5] Zeon Corp, Med Lab, Res & Dev Ctr, Toyama, Japan
[6] Juntendo Univ, Grad Sch Med, Dept Gastroenterol, 2-1-1 Hongo,Bunkyo Ku, Tokyo 1138421, Japan
关键词
Axial force; Cholestasis; Mechanical property; Radial force; Self-expandable metallic stent; RISK-FACTORS; OBSTRUCTION; CHOLECYSTITIS; MIGRATION;
D O I
10.5946/ce.2022.201
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability.Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated.Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20 degrees), followed by the laser-cut and cross types.Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.
引用
收藏
页码:633 / 649
页数:17
相关论文
共 22 条
  • [1] Measurement of radial and axial forces of biliary self-expandable metallic stents
    Isayama, Hiroyuki
    Nakai, Yousuke
    Toyokawa, Yoshihide
    Togawa, Osamu
    Gon, Chimyon
    Ito, Yukiko
    Yashima, Yoko
    Yagioka, Hiroshi
    Kogure, Hirofumi
    Sasaki, Takashi
    Arizumi, Toshihiko
    Matsubara, Saburo
    Yamamoto, Natsuyo
    Sasahira, Naoki
    Hirano, Kenji
    Tsujino, Takeshi
    Toda, Nobuo
    Tada, Minoru
    Kawabe, Takao
    Omata, Masao
    GASTROINTESTINAL ENDOSCOPY, 2009, 70 (01) : 37 - 44
  • [2] Novel characteristics of traction force in biliary self-expandable metallic stents
    Hori, Yasuki
    Hayashi, Kazuki
    Yoshida, Michihiro
    Naitoh, Itaru
    Ban, Tesshin
    Miyabe, Katsuyuki
    Kondo, Hiromu
    Nishi, Yuji
    Umemura, Shuichiro
    Fujita, Yasuaki
    Natsume, Makoto
    Kato, Akihisa
    Ohara, Hirotaka
    Joh, Takashi
    DIGESTIVE ENDOSCOPY, 2017, 29 (03) : 347 - 352
  • [3] Comparison of axial force and cell width of self-expandable metallic stents: which type of stent is better suited for hilar biliary strictures?
    Mukai, Tsuyoshi
    Yasuda, Ichiro
    Isayama, Hiroyuki
    Nakashima, Masanori
    Doi, Shinpei
    Iwashita, Takuji
    Iwata, Keisuke
    Kato, Tomohiro
    Tomita, Eiichi
    Moriwaki, Hisataka
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2011, 18 (05) : 646 - 652
  • [4] Comparing the mechanical properties of a self-expandable metallic stent for colorectal obstruction: Proposed measurement method of axial force using a new measurement machine
    Sasaki, Takashi
    Ishibashi, Rei
    Yoshida, Shuntaro
    Fujisawa, Toshio
    Shinagawa, Hiroki
    Gon, Chimyon
    Nakai, Yousuke
    Sasahira, Naoki
    Saida, Yoshihisa
    Isayama, Hiroyuki
    DIGESTIVE ENDOSCOPY, 2021, 33 (01) : 170 - 178
  • [5] A New Self-Expandable Metallic Stent with Low Axial Force and a High Axial Force Zero-Border Shows a Very Low Perforation Rate in Malignant Colorectal Obstruction: A Japanese Multicenter Prospective Study
    Murakami, Takashi
    Isayama, Hiroyuki
    Ikeda, Satoshi
    Hanabata, Norihiro
    Enomoto, Toshiyuki
    Kuwai, Toshio
    Ushigome, Mitsunori
    Ebi, Masahide
    Ohtsuka, Hideo
    Endo, Shungo
    Saito, Shuji
    Ohki, Takeshi
    Yamamoto, Ryuichi
    Kayahara, Takahisa
    Matsumoto, Satoshi
    Sasaki, Yoshihiro
    Saida, Yoshihisa
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [6] New concept of traction force applied to biliary self-expandable metallic stents
    Hori, Yasuki
    Hayashi, Kazuki
    Yoshida, Michihiro
    Naitoh, Itaru
    Nakazawa, Takahiro
    Miyabe, Katsuyuki
    Shimizu, Shuya
    Kondo, Hiromu
    Nishi, Yuji
    Umemura, Shuichiro
    Kato, Akihisa
    Ohara, Hirotaka
    Joh, Takashi
    ENDOSCOPY, 2016, 48 (05) : 472 - 476
  • [7] Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self-Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study
    Minato, Naoki
    Okuwaki, Kosuke
    Watanabe, Masafumi
    Woo, Jun
    Matsumoto, Takaaki
    Tadehara, Masayoshi
    Kaneko, Toru
    Ishizaki, Junro
    Iwai, Tomohisa
    Imaizumi, Hiroshi
    Kida, Mitsuhiro
    Haradome, Hiroki
    Kusano, Chika
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2025, 40 (02) : 502 - 509
  • [8] Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium
    Cabrera, Maria Sol
    Oomens, Cees W. J.
    Baaijens, Frank P. T.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 68 : 252 - 264
  • [9] Can we develop self-expandable metallic stents without consideration of mechanical properties?
    Isayama, Hiroyuki
    Nakai, Yousuke
    Kogure, Hirofumi
    Hamada, Tsuyoshi
    Yamamoto, Natsuyo
    Koike, Kazuhiko
    ENDOSCOPY, 2014, 46 (08) : 715 - 715
  • [10] Metallic stent with high axial force as a risk factor for cholecystitis in distal malignant biliary obstruction
    Nakai, Yousuke
    Isayama, Hiroyuki
    Kawakubo, Kazumichi
    Kogure, Hirofumi
    Hamada, Tsuyoshi
    Togawa, Osamu
    Ito, Yukiko
    Matsubara, Saburo
    Arizumi, Toshihiko
    Yagioka, Hiroshi
    Takahara, Naminatsu
    Uchino, Rie
    Mizuno, Suguru
    Miyabayashi, Koji
    Yamamoto, Keisuke
    Sasaki, Takashi
    Yamamoto, Natsuyo
    Hirano, Kenji
    Tada, Minoru
    Koike, Kazuhiko
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 (07) : 1557 - 1562