Digital signal processing for neutron-gamma discrimination using a liquid scintillator detector

被引:1
|
作者
Biganeh, A. [1 ]
Azizi, M. [2 ]
Kakuee, O. [1 ]
Rafi-Kheiri, H. [1 ]
Boorkhani, M. Sedaghati [1 ]
Ghasemi, B. [2 ]
机构
[1] Nucl Sci & Technol Res Inst, Phys & Accelerators Res Sch, POB 14395-836, Tehran, Iran
[2] Shahid Beheshti Univ, Dept Nucl Engn, Tehran, Iran
关键词
Digital signal processing (DSP); Electronic detector readout concepts (gas; liquid); Inspection with neutrons; RAYS;
D O I
10.1088/1748-0221/18/03/P03039
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Digital signal processing has shown promise as a reliable approach for nuclear radiation spectroscopy. In this paper, the charge-to-digital conversion technique was applied to neutron -gamma discrimination. The method is based on the direct comparison of the charge at the fast and slow components of the anode signal of the scintillator detector. The performance of the technique was tested using experimental investigation by 252Cf source and D-D neutron generator. The minimum detectable energy for reasonable separation was found to be around 0.2 MeVee. The FOM of the discrimination parameter was maximized by the optimum selection of the charge integration parameters. Excellent discrimination between neutron and gamma signals was confirmed by the presented setup. The results confirmed that the presented technique can replace analog nuclear electronics conventionally uses for pulse shape discrimination.
引用
收藏
页数:10
相关论文
共 41 条
  • [21] Robust pulse shape discrimination algorithm using canonical correlation analysis of gamma and neutron pulses
    El-Shazly, Ehab H.
    Abdelhakim, Assem
    JOURNAL OF INSTRUMENTATION, 2023, 18 (01)
  • [22] Digital pulse shape discrimination technique for liquid scintillation detector EJ-301
    Bo, W.
    Gang, L.
    Kun, L.
    Zhi, C.
    Yu, H.
    Hu, Z.
    Cheng, Y.
    Daibo, Y.
    Shaoli, Z.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (11)
  • [23] Neutron generator burst timing measured using a pulse shape discrimination plastic scintillator with silicon photomultiplier readout
    Preston, R. M.
    Eberhardt, J. E.
    Tickner, J. R.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [24] Investigation of three-dimensional localisation of radioactive sources using a fast organic liquid scintillator detector
    Gamage, K. A. A.
    Joyce, M. J.
    Taylor, G. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 707 : 123 - 126
  • [25] A digital signal processing teaching methodology using concept-mapping techniques
    Martínez-Torres, MR
    García, FJB
    Marín, SLT
    Vázquez, SG
    IEEE TRANSACTIONS ON EDUCATION, 2005, 48 (03) : 422 - 429
  • [26] Simultaneous alpha and gamma discrimination with a phoswich detector using a rise time method and an artificial neural network method
    Panahi, R.
    Feghhi, S. A. H.
    Moghadam, S. Rajabi
    Zamzamian, S. M.
    APPLIED RADIATION AND ISOTOPES, 2019, 154
  • [27] On-line fuel identification using digital signal processing and fuzzy inference techniques
    Xu, LJ
    Yan, Y
    Cornwell, S
    Riley, G
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (04) : 1316 - 1320
  • [28] Wavelet-based digital pulse-shape method for discrimination between neutron and gamma-rays with organic scintillation detectors
    Alharbi, Thamer
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2024, 36 (08)
  • [29] A Composite Method for Improving the Pulse Shape Discrimination Efficiency of a Scintillation Detector Using EJ-301 Liquid
    Phan Van Chuan
    Nguyen Xuan Hai
    Nguyen Ngoc Anh
    Pham Dinh Khang
    Nguyen Quang Hung
    Truong Van Minh
    Nguyen Duy Ly
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [30] Downlink transmission in coherent passive optical network at 400 Gbps using digital signal processing
    Pandey, Gaurav
    Goel, Aditya
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2017, 11 (11-12): : 652 - 658