Cooling performance evaluation of a fan-assisted ceiling radiant cooling panel system

被引:15
作者
Choi, Ji-Su [1 ]
Jung, Gun-Joo [2 ]
Rhee, Kyu-Nam [2 ]
机构
[1] Pukyong Natl Univ, Grad Sch, Div Architectural & Fire Safety Engn, 45 Yongso Ro, Busan 48513, South Korea
[2] Pukyong Natl Univ, Dept Architectural Engn, 45 Yongso Ro, Busan 48513, South Korea
关键词
Ceiling radiant cooling panel; Air flow; Cooling performance; Cooling capacity; Thermal environment; MIXED CONVECTION; CAPACITY;
D O I
10.1016/j.enbuild.2022.112760
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ceiling radiant cooling panel (CRCP) systems have been widely used for space cooling owing to high thermal comfort and energy efficiency. However, it has been reported that the cooling capacity of CRCP systems can be limited because panel surface temperature should be maintained above the dew-point temperature in order to avoid the condensation risk. Previous studies showed that this limitation can be overcome by applying air flow to the panel surface using parallel HVAC systems. However, as additional costs and space are required to install parallel HVAC systems, a simple and low-cost system needs to be considered to enhance the cooling capacity. In this context, the present study was conducted to develop a fan-assisted ceiling radiant cooling panel (FCRCP) system wherein small and low-cost fans are associated with the CRCP, in order to minimize the modification of architectural or mechanical elements. To evaluate the performance of this system, mock-up experiments were conducted to evaluate the cooling performance of the FCRCP system. Numerical analysis was also performed to compare the cooling performance of various FCRCP alternatives. The cooling performance was analyzed for the thermal environment and cooling capacity depending on the type, location, and arrangement of the fans. Simulation results showed that the FCRCP can enhance the cooling capacity by 73-112 %, reduce the indoor temperature by 0.4-0.9 degrees C, and elevate the air velocity by up to 0.17-0.33 m/s, when compared to conventional CRCP system. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:15
相关论文
共 34 条
[1]   Numerical investigation of a new method to control the condensation problem in ceiling radiant cooling panels [J].
Amini, Mohsen ;
Maddahian, Reza ;
Saemi, Simindokht .
JOURNAL OF BUILDING ENGINEERING, 2020, 32
[2]   Experimental study on the cooling capacity of a radiant cooled ceiling system [J].
Andres-Chicote, Manuel ;
Tejero-Gonzalez, Ana ;
Velasco-Gomez, Eloy ;
Javier Rey-Martinez, Francisco .
ENERGY AND BUILDINGS, 2012, 54 :207-214
[3]  
[Anonymous], 2005, International Organization for Standardization ISO 11269-2. Soil quality: determination of the effects of pollutants on soil flora -Part 2: Effects of chemicals on the emergence and growth of higher plants, DOI DOI 10.1016/J.SOILDYN.2004.11.005
[4]  
[Anonymous], 2010, THERMAL ENV CONDITIO
[5]  
Ashrae, 2020, ASHRAE HDB HVAC SYST
[6]  
Babiak J., 2009, LOW TEMPERATURE HEAT
[7]   Evaluation of thermal comfort using combined CFD and experimentation study in a test room equipped with a cooling ceiling [J].
Catalina, Tiberiu ;
Virgone, Joseph ;
Kuznik, Frederic .
BUILDING AND ENVIRONMENT, 2009, 44 (08) :1740-1750
[8]  
CEN, 2004, 14240 EN CEN
[9]   HYDRONIC RADIANT COOLING - PRELIMINARY ASSESSMENT [J].
FEUSTEL, HE ;
STETIU, C .
ENERGY AND BUILDINGS, 1995, 22 (03) :193-205
[10]   Impact of mixed convection on ceiling radiant cooling panel capacity [J].
Jeong, JW ;
Mumma, SA .
HVAC&R RESEARCH, 2003, 9 (03) :251-257