摘要
This article describes the synthesis of nanostructured cobalt oxide on iron wires and its application for the detection of hydrogen peroxide as working electrode for non-enzymatic electrochemical sensor. Cobalt oxide was obtained by the hydrothermal synthesis method using chloride and acetate anions. The resulting nanostructured coating obtained from the chloride precursor is a uniform homogeneous porous network of long nanofibers assembled into regular honey & scy;omb-like formations. In the case of an acetate precursor, instead of nanofibers, petal-like nanostructures assembled into honeycomb agglomerates are observed. The structure, surface, and composition of the obtained samples were studied using field-emission scanning electron microscopy along with energy-dispersive spectroscopy and X-ray diffractometry.The resultant nanostructured specimens were utilized to detect H2O2 electrochemically through cyclic voltammetry, differential pulse voltammetry, and i-t measurements. A comparative research has demonstrated that the nanostructures produced from the chloride precursor exhibit greater sensitivity to H2O2 and have a more appropriate morphology for designing a nanostructured sensor. A substantial linear correlation between the peak current and H2O2 concentration within the 20 to 1300 mu M range was established. The Co3O(4) electrode obtained exhibits a sensitivity of 505.11 mu A<middle dot>mM(-1), and the electroactive surface area is calculated to be 4.684 cm(2). Assuming a signal-to-noise ratio of 3, the calculated limit of detection is 1.05 mu M. According to the interference study, the prevalent interfering agents, such as ascorbic acid, uric acid, NaCl, and glucose, do not influence the electrochemical reaction. The obtained results confirm that this sensor is suitable for working with complex analytes.The actual sample assessment demonstrated a recovery rate exceeding 95 %.
引用
收藏
页码:63 / 84
页数:22
相关论文
共 50 条
  • [41] ZIF-67 Derived Co3O4/rGO Electrodes for Electrochemical Detection of H2O2 with High Sensitivity and Selectivity
    Wu, Meiyan
    Hong, Ying
    Zang, Xiaoxian
    Dong, Xiaochen
    CHEMISTRYSELECT, 2016, 1 (18): : 5727 - 5732
  • [42] Porous Co3O4 nanosheets as a high-performance non-enzymatic sensor for glucose detection
    Liu, Fuyan
    Wang, Peng
    Zhang, Qianqian
    Wang, Zeyan
    Liu, Yuanyuan
    Zheng, Zhaoke
    Qin, Xiaoyan
    Zhang, Xiaoyang
    Dai, Ying
    Li, Lu
    Huang, Baibiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (29) : 7663 - 7670
  • [43] A non-enzymatic sensor based on Au@Ag nanoparticles with good stability for sensitive detection of H2O2
    Li, Zhi
    Zheng, Xiaohui
    Zheng, Jianbin
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (03) : 2115 - 2120
  • [44] Co3O4 Nanostructured Sensor for Electrochemical Detection of H2O2 as a Stress Biomarker in Barley: Fe3O4 Nanoparticles-Mediated Enhancement of Salt Stress Tolerance
    Gerbreders, Vjaceslavs
    Krasovska, Marina
    Sledevskis, Eriks
    Mihailova, Irena
    Mizers, Valdis
    MICROMACHINES, 2024, 15 (03)
  • [45] Fabrication of Co3O4/NiCo2O4 Nanocomposite for Detection of H2O2 and Dopamine
    Liu, Tianjiao
    Zhang, Xiaoyuan
    Fu, Kun
    Zhou, Nan
    Xiong, Jinping
    Su, Zhiqiang
    BIOSENSORS-BASEL, 2021, 11 (11):
  • [46] A Co3O4 nano-octahedron modified fluorine doped tin oxide electrochemical sensor for detection of benzobicyclon
    Puangjan, Apinya
    Chaiyasith, Suwan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 813 : 20 - 30
  • [47] A colorimetric sensor of H2O2 based on Co3O4-montmorillonite nanocomposites with peroxidase activity
    Zhu, Xixi
    Chen, Wei
    Wu, Kaili
    Li, Hongyu
    Fu, Min
    Liu, Qingyun
    Zhang, Xiao
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (02) : 1501 - 1509
  • [48] Progress of Advanced Nanomaterials in the Non-Enzymatic Electrochemical Sensing of Glucose and H2O2
    Thatikayala, Dayakar
    Ponnamma, Deepalekshmi
    Sadasivuni, Kishor Kumar
    Cabibihan, John-John
    Al-Ali, Abdulaziz Khalid
    Malik, Rayaz A.
    Min, Booki
    BIOSENSORS-BASEL, 2020, 10 (11):
  • [49] A non-enzymatic sensor for sensitive determination of H2O2 using biomimetic nanocomposite
    Mukherjee, Atripan
    Ashrafi, Amir
    Richtera, Lukas
    Adam, Vojtech
    MENDELNET 2019: PROCEEDINGS OF 26TH INTERNATIONAL PHD STUDENTS CONFERENCE, 2019, : 585 - 590
  • [50] Hollow Co3O4 microspheres assembled with nanocrystals for non-enzymatic glucose sensor
    Yin, Haoyong
    He, Xiaolong
    Cui, Zhenzhen
    Nie, Qiulin
    MICRO & NANO LETTERS, 2016, 11 (03): : 151 - 155