High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose

被引:26
|
作者
Rajiah, Prabhakar Shantha [1 ]
Dunning, Chelsea A. S. [1 ]
Rajendran, Kishore [1 ]
Tandon, Yasmeen K. [1 ]
Ahmed, Zaki [1 ]
Larson, Nicholas B. [2 ]
Collins, Jeremy D. [1 ]
Thorne, Jamison [1 ]
Williamson, Eric [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ,3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Mayo Clin, Dept Quantitat Hlth Sci, Rochester, MN USA
[3] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
coronary CTA; atherosclerosis; iodine; virtual monoenergetic image; photon-counting detector CT; calcium blooming; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; AMERICAN-COLLEGE; PHANTOM; SYSTEM; MEDIA; RADIOLOGY; DISEASE;
D O I
10.1097/RLI.0000000000000961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA).Materials and MethodsHigh-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 x 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0-100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest).ResultsThe radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 & PLUSMN; 0.6 mGy and 3.1 & PLUSMN; 1.7 mGy, respectively (P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 & PLUSMN; 76.2, distal LAD 341.0 & PLUSMN; 53.9, AA 399.5 & PLUSMN; 76.1) and 50 keV images (LMCA 667.5 & PLUSMN; 139.9, distal LAD 578.1 & PLUSMN; 121.5, AA 700.8 & PLUSMN; 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher (P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly (P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher (P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images.ConclusionsHigh-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [31] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Liu, Ying
    Xu, Jian
    Li, Jian
    Ren, Jing
    Liu, Hongtao
    Xu, Junqing
    Wei, Mengqi
    Hao, Yuewen
    Zheng, Minwen
    JOURNAL OF CARDIOTHORACIC SURGERY, 2013, 8
  • [32] High-Pitch Dual-Source CT Angiography of the Thoracic and Abdominal Aorta: Is Simultaneous Coronary Artery Assessment Possible?
    Goetti, Robert
    Baumueller, Stephan
    Feuchtner, Gudrun
    Stolzmann, Paul
    Karlo, Christoph
    Alkadhi, Hatem
    Leschka, Sebastian
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) : 938 - 944
  • [33] Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT
    Konstantin Klambauer
    Thomas Flohr
    Lukas Jakob Moser
    Victor Mergen
    Matthias Eberhard
    Andreas Prokein
    Hatem Alkadhi
    Hubertus Pietsch
    Gregor Jost
    European Radiology Experimental, 9 (1)
  • [34] Multi-energy CT imaging for large patients using dual-source photon-counting detector CT
    Tao, Shengzhen
    Marsh, Jeffrey F.
    Tao, Ashley
    Michalak, Greg J.
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (17):
  • [35] Dual-Source Photon-Counting Computed Tomography-Part I: Clinical Overview of Cardiac CT and Coronary CT Angiography Applications
    Cademartiri, Filippo
    Meloni, Antonella
    Pistoia, Laura
    Degiorgi, Giulia
    Clemente, Alberto
    Gori, Carmelo De
    Positano, Vincenzo
    Celi, Simona
    Berti, Sergio
    Emdin, Michele
    Panetta, Daniele
    Menichetti, Luca
    Punzo, Bruna
    Cavaliere, Carlo
    Bossone, Eduardo
    Saba, Luca
    Cau, Riccardo
    Grutta, Ludovico La
    Maffei, Erica
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (11)
  • [36] High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates
    Bischoff, Bernhard
    Meinel, Felix G.
    Del Prete, Alessandra
    Reiser, Maximilian F.
    Becker, Hans-Christoph
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) : 2217 - 2221
  • [37] Visualization of bone details in a novel photon-counting dual-source CT scanner—comparison with energy-integrating CT
    Stefanie J. Bette
    Franziska M. Braun
    Mark Haerting
    Josua A. Decker
    Jan H. Luitjens
    Christian Scheurig-Muenkler
    Thomas J. Kroencke
    Florian Schwarz
    European Radiology, 2022, 32 : 2930 - 2936
  • [38] Consistency of spectral results in cardiac dual-source photon-counting CT
    Liu, Leening P.
    Shapira, Nadav
    Sahbaee, Pooyan
    Gang, Grace J.
    Knollman, Friedrich D.
    Chen, Marcus Y.
    Litt, Harold I.
    Noel, Peter B.
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [39] Consistency of spectral results in cardiac dual-source photon-counting CT
    Leening P. Liu
    Nadav Shapira
    Pooyan Sahbaee
    Grace J. Gang
    Friedrich D. Knollman
    Marcus Y. Chen
    Harold I. Litt
    Peter B. Noël
    Scientific Reports, 13
  • [40] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Thomas, C.
    Ketelsen, D.
    Claussen, C. D.
    Moonis, G.
    Krauss, B.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    NEURORADIOLOGY, 2013, 55 (04) : 423 - 430