High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose

被引:26
|
作者
Rajiah, Prabhakar Shantha [1 ]
Dunning, Chelsea A. S. [1 ]
Rajendran, Kishore [1 ]
Tandon, Yasmeen K. [1 ]
Ahmed, Zaki [1 ]
Larson, Nicholas B. [2 ]
Collins, Jeremy D. [1 ]
Thorne, Jamison [1 ]
Williamson, Eric [1 ]
Fletcher, Joel G. [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ,3 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN USA
[2] Mayo Clin, Dept Quantitat Hlth Sci, Rochester, MN USA
[3] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
基金
美国国家卫生研究院;
关键词
coronary CTA; atherosclerosis; iodine; virtual monoenergetic image; photon-counting detector CT; calcium blooming; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; AMERICAN-COLLEGE; PHANTOM; SYSTEM; MEDIA; RADIOLOGY; DISEASE;
D O I
10.1097/RLI.0000000000000961
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectivesThe aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA).Materials and MethodsHigh-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 x 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0-100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest).ResultsThe radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 & PLUSMN; 0.6 mGy and 3.1 & PLUSMN; 1.7 mGy, respectively (P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 & PLUSMN; 76.2, distal LAD 341.0 & PLUSMN; 53.9, AA 399.5 & PLUSMN; 76.1) and 50 keV images (LMCA 667.5 & PLUSMN; 139.9, distal LAD 578.1 & PLUSMN; 121.5, AA 700.8 & PLUSMN; 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher (P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly (P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher (P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images.ConclusionsHigh-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [21] Evaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography
    Rippel, K.
    Luitjens, J.
    Habeeballah, O.
    Scheurig-Muenkler, C.
    Bette, Stefanie
    Braun, Franziska
    Kroencke, T. J.
    Schwarz, F.
    Decker, J. A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [22] Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience
    Fabian Morsbach
    Sonja Gordic
    Lotus Desbiolles
    Daniela Husarik
    Thomas Frauenfelder
    Bernhard Schmidt
    Thomas Allmendinger
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2014, 24 : 1889 - 1895
  • [23] Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic phantom study
    van der Werf, Niels R.
    Booij, Ronald
    Greuter, Marcel J. W.
    Bos, Daniel
    van der Lugt, A.
    Budde, R. P. J.
    van Straten, Marcel
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2022, 38 (07): : 1613 - 1619
  • [24] Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries
    Sun, Kai
    Li, Kuncheng
    Han, Ruijuan
    Li, Wenhuan
    Chen, Nan
    Yang, Qi
    Du, Xiangying
    Wang, Chen
    Liu, Guorong
    Li, Yuechun
    Zhou, Maorong
    Li, Ligang
    Heidrun, Endt
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (03) : 398 - 406
  • [25] Strengths and limitations of coronary angiography with turbo high-pitch third-generation dual-source CT
    Ochs, M. M.
    Andre, F.
    Korosoglou, G.
    Fritz, T.
    Seitz, S.
    Bogomazov, Y.
    Schlett, C. L.
    Sokiranski, R.
    Sommer, A.
    Gueckel, F.
    Brado, M.
    Kauczor, H. -U.
    Goerich, J.
    Buss, S. J.
    CLINICAL RADIOLOGY, 2017, 72 (09) : 739 - 744
  • [26] High-pitch Dual-source CT Angiography before TAVI - the Value of ECG Gating
    Bucher, Andreas Michael
    Albrecht, Moritz Hans
    Scholtz, Jan Erik
    Herrmann, Eva
    Kaup, Moritz
    Gruber-Rouh, Tatjana
    Jacobi, Volkmar
    Vogl, Thomas Josef
    Beeres, Martin
    CURRENT MEDICAL IMAGING REVIEWS, 2019, 15 (04) : 373 - 379
  • [27] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Ying Liu
    Jian Xu
    Jian Li
    Jing Ren
    Hongtao Liu
    Junqing Xu
    Mengqi Wei
    Yuewen Hao
    Minwen Zheng
    Journal of Cardiothoracic Surgery, 8
  • [28] Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode
    Alkadhi, Hatem
    Stolzmann, Paul
    Desbiolles, Lotus
    Baumueller, Stephan
    Goetti, Robert
    Plass, Andre
    Scheffel, Hans
    Feuchtner, Gudrun
    Falk, Volkmar
    Marincek, Borut
    Leschka, Sebastian
    HEART, 2010, 96 (12) : 933 - 938
  • [29] Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography
    Yang, Junjie
    Yang, Xiaobo
    De Cecco, Carlo N.
    Duguay, Taylor M.
    Chen, Zhiye
    Tesche, Christian
    Schoepf, U. Joseph
    Chen, Yundai
    SCIENTIFIC REPORTS, 2017, 7
  • [30] Iterative reconstruction improves detection of in-stent restenosis by high-pitch dual-source coronary CT angiography
    Junjie Yang
    Xiaobo Yang
    Carlo N. De Cecco
    Taylor M. Duguay
    Zhiye Chen
    Christian Tesche
    U. Joseph Schoepf
    Yundai Chen
    Scientific Reports, 7