Pinch point variation in the gas cooler of the CO2 heat pump water heater: An experimental and simulation comparative study

被引:7
作者
Cui, Qi [1 ]
Gao, Enyuan [1 ,3 ,4 ]
Wei, Dianhang [1 ]
Qi, Pengcheng [5 ]
Zhang, Xiaosong [1 ,2 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
[2] Minist Educ, Engn Res Ctr BEEE, Beijing, Peoples R China
[3] Hua Shang Int Engn Co Ltd, Beijing 100069, Peoples R China
[4] Chinese Assoc Refrigerat, Beijing 100142, Peoples R China
[5] Jiangsu JTL Solar Nucl Power Technol Co Ltd, Wuxi 214000, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon dioxide heat pump; Gas cooler; Pinch point; Experimental investigation; DISCHARGE PRESSURE; PERFORMANCE; ADSORPTION; COMPOSITE;
D O I
10.1016/j.tsep.2023.101959
中图分类号
O414.1 [热力学];
学科分类号
摘要
The carbon dioxide heat pump operation is strongly impacted by the presence of the pinch point within the gas cooler. The existing findings regarding the pinch point need to be verified due to the deficiencies of the simu-lation method. Given this, an experimental and simulation comparative study is performed. The pinch point variation characteristics and its connection with the heat pump operation are elucidated. The limitations and accuracy of the simulation model are revealed. The location and number of the pinch point are at most four scenarios. One locates at inside. Two locate at inside and cold end, respectively. One locates at cold end. One locates at hot end. The hot end pinch point is difficult to occur for actual heat pump operating conditions. As the carbon dioxide pressure rises, the pinch point temperature difference first grows slightly and then drops. The experiments demonstrated that the actual best operation of the carbon dioxide heat pump corresponds to one inside pinch point rather than two. The simulation model cannot reproduce this phenomenon well. The accuracy of the simulation model can be greatly improved in case the pinch point location is known, and it is acceptable from the perspective of meeting the engineering permissible error. This study may contribute to a better un-derstanding of the pinch point variation. Moreover, it may play a reference role in the building and optimization of the gas cooler model.
引用
收藏
页数:11
相关论文
共 35 条
[31]   An updated review of recent advances on modified technologies in transcritical CO2 refrigeration cycle [J].
Yu, Binbin ;
Yang, Jingye ;
Wang, Dandong ;
Shi, Junye ;
Chen, Jiangping .
ENERGY, 2019, 189
[32]   Heat transfer and pressure drop of supercritical CO2 in brazed plate heat exchangers of the tri-partite gas cooler [J].
Zendehboudi, Alireza ;
Ye, Zuliang ;
Hafner, Armin ;
Andresen, Trond ;
Skaugen, Geir .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 178
[33]   Thermodynamic analysis of a novel multi-target temperature transcritical CO2 ejector-expansion refrigeration cycle with vapor-injection [J].
Zeng, Min-Qiang ;
Zheng, Qiu-Yun ;
Zhang, Xue-Lai ;
Mo, Fan-Yang ;
Zhang, Xin-Rong .
ENERGY, 2022, 259
[34]   The effect of heat conduction through fins on the performance of finned-tube CO2 supercritical gas coolers [J].
Zhang, X. ;
Ge, Y. T. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 181
[35]   Performance analysis of finned-tube CO2 gas cooler with advanced 1D-3D CFD modelling development and simulation [J].
Zhang, X. Y. ;
Ge, Y. T. ;
Sun, J. N. .
APPLIED THERMAL ENGINEERING, 2020, 176