Towards virtual histology with X-ray grating interferometry

被引:4
作者
Polikarpov, M. [1 ,2 ]
Vila-Comamala, J. [1 ]
Wang, Z. [1 ,2 ,8 ]
Pereira, A. [1 ,2 ]
van Gogh, S. [1 ,2 ]
Gasser, C. [2 ]
Jefimovs, K. [1 ]
Romano, L. [1 ,2 ]
Varga, Z. [3 ]
Lang, K. [4 ,5 ]
Schmeltz, M. [1 ]
Tessarini, S. [1 ,2 ]
Rawlik, M. [1 ,2 ]
Jermann, E. [6 ]
Lewis, S. [7 ]
Yun, W. [7 ]
Stampanoni, M. [1 ,2 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Pathol & Mol Pathol, CH-8091 Zurich, Switzerland
[4] Lund Univ, Dept Diagnost Radiol, Translat Med, Lund, Sweden
[5] Skane Univ Hosp, Unilabs Mammog Unit, Malmo, Sweden
[6] Ecole Polytech Fed Lausanne, Lausanne, Switzerland
[7] Sigray Inc, Concord, CA 94520 USA
[8] Tsinghua Univ, Dept Engn Phys, Beijing 100080, Peoples R China
基金
欧洲研究理事会;
关键词
PHASE-CONTRAST; SYNCHROTRON-RADIATION; MAMMOGRAPHY; VISUALIZATION; RESOLUTION;
D O I
10.1038/s41598-023-35854-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Breast cancer is the most common type of cancer worldwide. Diagnosing breast cancer relies on clinical examination, imaging and biopsy. A core-needle biopsy enables a morphological and biochemical characterization of the cancer and is considered the gold standard for breast cancer diagnosis. A histopathological examination uses high-resolution microscopes with outstanding contrast in the 2D plane, but the spatial resolution in the third, Z-direction, is reduced. In the present paper, we propose two high-resolution table-top systems for phase-contrast X-ray tomography of soft-tissue samples. The first system implements a classical Talbot-Lau interferometer and allows to perform ex-vivo imaging of human breast samples with a voxel size of 5.57 mu m. The second system with a comparable voxel size relies on a Sigray MAAST X-ray source with structured anode. For the first time, we demonstrate the applicability of the latter to perform X-ray imaging of human breast specimens with ductal carcinoma in-situ. We assessed image quality of both setups and compared it to histology. We showed that both setups made it possible to target internal features of breast specimens with better resolution and contrast than previously achieved, demonstrating that grating-based phase-contrast X-ray CT could be a complementary tool for clinical histopathology.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Automatic histology registrationin application to X-ray modalities
    Chicherova, Natalia
    Hieber, Simone E.
    Schulz, Georg
    Khimchenko, Anna
    Bikis, Christos
    Catttin, Philippe C.
    Mueller, Bert
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [22] X-ray Interferometry with Two-Dimensional Gratings
    Zanette, I.
    Rutishauser, S.
    David, C.
    Weitkamp, T.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 325 - 328
  • [23] Hard X-ray phase-contrast tomography of non-homogeneous specimens: grating interferometry versus propagation-based imaging
    Ruiz-Yaniz, Maite
    Zanette, Irene
    Sarapata, Adrian
    Birnbacher, Lorenz
    Marschner, Mathias
    Chabior, Michael
    Olbinado, Margie
    Pfeiffer, Franz
    Rack, Alexander
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1202 - 1209
  • [24] Applications of X-ray intensity interferometry
    Yabashi, M
    Tamasaku, K
    Ishikawa, T
    X-RAY MIRRORS, CRYSTALS, AND MULTILAYERS II, 2002, 4782 : 122 - 131
  • [25] wavepy - Python']Python package for x-ray grating interferometry with applications in imaging and wavefront characterization
    Grizolli, Walan
    Shi, Xianbo
    Assoufid, Lahsen
    Butler, Leslie G.
    13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
  • [26] Monitoring moisture distribution in textile materials using grating interferometry and ptychographic X-ray imaging
    Esmaeili, Morteza
    Floystad, Jostein B.
    Hipp, Alexander
    Willner, Marian
    Bech, Martin
    Diaz, Ana
    Royset, Arne
    Andreasen, Jens W.
    Pfeiffer, Franz
    Breiby, Dag W.
    TEXTILE RESEARCH JOURNAL, 2015, 85 (01) : 80 - 90
  • [27] Nucleus-specific X-ray stain for 3D virtual histology
    Mueller, Mark
    Kimm, Melanie A.
    Ferstl, Simone
    Allner, Sebastian
    Achterhold, Klaus
    Herzen, Julia
    Pfeiffer, Franz
    Busse, Madleen
    SCIENTIFIC REPORTS, 2018, 8
  • [28] X-ray Phase Measurements with Talbot Interferometry and Its Applications
    Momose, Atsushi
    Yashiro, Wataru
    INTERNATIONAL CONFERENCE ON ADVANCED PHASE MEASUREMENT METHODS IN OPTICS AN IMAGING, 2010, 1236 : 195 - 199
  • [29] Empirical beam hardening and ring artifact correction for x-ray grating interferometry (EBHC-GI)
    Nelson, Brandon J.
    Leng, Shuai
    Shanblatt, Elisabeth R.
    McCollough, Cynthia H.
    Koenig, Thomas
    MEDICAL PHYSICS, 2021, 48 (03) : 1327 - 1340
  • [30] X-ray grating interferometry for 9.25 keV design energy at a liquid-metal-jet source
    Balles, A.
    Fella, Ch
    Dittmann, J.
    Wiest, W.
    Zabler, S.
    Hanke, R.
    XRM 2014: PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2016, 1696