Towards virtual histology with X-ray grating interferometry

被引:4
|
作者
Polikarpov, M. [1 ,2 ]
Vila-Comamala, J. [1 ]
Wang, Z. [1 ,2 ,8 ]
Pereira, A. [1 ,2 ]
van Gogh, S. [1 ,2 ]
Gasser, C. [2 ]
Jefimovs, K. [1 ]
Romano, L. [1 ,2 ]
Varga, Z. [3 ]
Lang, K. [4 ,5 ]
Schmeltz, M. [1 ]
Tessarini, S. [1 ,2 ]
Rawlik, M. [1 ,2 ]
Jermann, E. [6 ]
Lewis, S. [7 ]
Yun, W. [7 ]
Stampanoni, M. [1 ,2 ]
机构
[1] Paul Scherrer Inst, Swiss Light Source, CH-5232 Villigen, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[3] Univ Hosp Zurich, Dept Pathol & Mol Pathol, CH-8091 Zurich, Switzerland
[4] Lund Univ, Dept Diagnost Radiol, Translat Med, Lund, Sweden
[5] Skane Univ Hosp, Unilabs Mammog Unit, Malmo, Sweden
[6] Ecole Polytech Fed Lausanne, Lausanne, Switzerland
[7] Sigray Inc, Concord, CA 94520 USA
[8] Tsinghua Univ, Dept Engn Phys, Beijing 100080, Peoples R China
基金
欧洲研究理事会;
关键词
PHASE-CONTRAST; SYNCHROTRON-RADIATION; MAMMOGRAPHY; VISUALIZATION; RESOLUTION;
D O I
10.1038/s41598-023-35854-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Breast cancer is the most common type of cancer worldwide. Diagnosing breast cancer relies on clinical examination, imaging and biopsy. A core-needle biopsy enables a morphological and biochemical characterization of the cancer and is considered the gold standard for breast cancer diagnosis. A histopathological examination uses high-resolution microscopes with outstanding contrast in the 2D plane, but the spatial resolution in the third, Z-direction, is reduced. In the present paper, we propose two high-resolution table-top systems for phase-contrast X-ray tomography of soft-tissue samples. The first system implements a classical Talbot-Lau interferometer and allows to perform ex-vivo imaging of human breast samples with a voxel size of 5.57 mu m. The second system with a comparable voxel size relies on a Sigray MAAST X-ray source with structured anode. For the first time, we demonstrate the applicability of the latter to perform X-ray imaging of human breast specimens with ductal carcinoma in-situ. We assessed image quality of both setups and compared it to histology. We showed that both setups made it possible to target internal features of breast specimens with better resolution and contrast than previously achieved, demonstrating that grating-based phase-contrast X-ray CT could be a complementary tool for clinical histopathology.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Design Aspects of X-Ray Grating Interferometry
    Weitkamp, Timm
    Zanette, Irene
    Pfeiffer, Franz
    David, Christian
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 84 - 89
  • [2] Sensitivity of X-ray grating interferometry
    Modregger, P.
    Pinzer, B. R.
    Thuering, T.
    Rutishauser, S.
    David, C.
    Stampanoni, M.
    OPTICS EXPRESS, 2011, 19 (19): : 18324 - 18338
  • [3] Holotomography versus X-ray grating interferometry: A comparative study
    Zanette, I.
    Lang, S.
    Rack, A.
    Dominietto, M.
    Langer, M.
    Pfeiffer, F.
    Weitkamp, T.
    Mueller, B.
    APPLIED PHYSICS LETTERS, 2013, 103 (24)
  • [4] X-ray grating interferometry at photon energies over 180 keV
    Ruiz-Yaniz, M.
    Koch, F.
    Zanette, I.
    Rack, A.
    Meyer, P.
    Kunka, D.
    Hipp, A.
    Mohr, J.
    Pfeiffer, F.
    APPLIED PHYSICS LETTERS, 2015, 106 (15)
  • [5] Towards X-ray transient grating spectroscopy
    Svetina, C.
    Mankowsky, R.
    Knopp, G.
    Koch, F.
    Seniutinas, G.
    Rosner, B.
    Kubec, A.
    Lebugle, M.
    Mochi, I.
    Beck, M.
    Cirelli, C.
    Krempasky, J.
    Pradervand, C.
    Rouxel, J.
    Mancini, G. F.
    Zerdane, S.
    Pedrini, B.
    Esposito, V.
    Ingold, G.
    Wagner, U.
    Flechsig, U.
    Follath, R.
    Chergui, M.
    Milne, C.
    Lemke, H. T.
    David, C.
    Beaud, P.
    OPTICS LETTERS, 2019, 44 (03) : 574 - 577
  • [6] Beam hardening correction in polychromatic x-ray grating interferometry
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    OPTICS EXPRESS, 2017, 25 (20): : 24690 - 24704
  • [7] Analysis of surface absorbed dose in X-ray grating interferometry
    Wang, Zhili
    Wu, Zhao
    Gao, Kun
    Wang, Dajiang
    Chen, Heng
    Wang, Shenghao
    Wu, Ziyu
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2014, 196 : 85 - 88
  • [8] Predicting visibility of interference fringes in X-ray grating interferometry
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    OPTICS EXPRESS, 2016, 24 (14): : 15927 - 15939
  • [9] Quantitative coherence analysis of dual phase grating x-ray interferometry with source grating*
    Wang, Zhi-Li
    Zhou, Rui-Cheng
    Zhao, Li-Ming
    Ren, Kun
    Xu, Wen
    Liu, Bo
    Chen, Heng
    CHINESE PHYSICS B, 2021, 30 (02)
  • [10] Large view x-ray imaging for oversized sample with the grating interferometry
    Zhu, Xiaohua
    Zhang, Li
    Jiang, Xiaolei
    Zhang, Ran
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,