Data-driven research into the inaccuracy of traditional models of thermal comfort in offices

被引:6
|
作者
Caro, Rosana [1 ]
Marrero, Maria Dolores Redondas [2 ]
Martinez, Arturo [1 ]
Cuerda, Elena [3 ]
Barbero-Barrera, Maria del Mar [1 ]
Neila, Javier [1 ]
Aguillon-Robles, Jorge [4 ]
Ramos-Palacios, Carlos Renato [4 ]
机构
[1] Univ Politecn Madrid, Escuela Tecn Super Arquitectura ETSAM, Avda Juan de Herrera 4, Madrid 28040, Spain
[2] Univ Politecn Madrid UPM, Escuela Tecn Super Edificac, Dept Matemat Aplicada, Avda Juan Herrera 6, Madrid 28040, Spain
[3] Univ Alcala, Dept Arquitectura, Calle Santa Ursula 8, Alcala De Henares 28801, Madrid, Spain
[4] Univ Autonoma San Luis Potosi, Fac Habitat, Inst Invest & Posgrad, Ave Nino Artillero 150, San Luis Potosi 78290, Mexico
关键词
Thermal comfort; Comfort in offices; Comfort monitoring and assessment; Analytical comfort models; Multiple regression in comfort analysis; Comfort prediction in workspaces; PMV; BUILDINGS; ACCURACY; CLIMATE;
D O I
10.1016/j.buildenv.2023.111104
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The accurate prediction of thermal sensation among office workers, at design and post-occupancy stages, is crucial for controlling indoor temperature efficiently and correcting deficiencies in workspaces, ensuring healthy and productive working conditions. Traditional analytical comfort models are still the best tool for this purpose given their potential for interpretation. However, their reliability is undermined by their poor accuracy. Based on 304 data series of point-in-time measurements of quantitative and qualitative comfort-related parameters collected in an experimental campaign in three office buildings, one air-conditioned and two in free evolution, in San Luis Potosi (Mexico), this work aims to identify the major error-causing factors of steady and adaptive comfort models. The divergences between predicted and reported thermal sensation were set as a dependant variable of two multiple regressions, one for each model. Eighteen independent demographic, environmental, contextual and subjective variables were considered. No multicollinearity problems were identified. Our findings show that contextual factors and humidity perception were relevant in the adaptive model error. Clothing insulation highly impacted the accuracy of both models while age and body mass were not statistically significant for either of them. Metabolic rate was the factor with the greatest influence in the error of the steady model. Although not covered, other influential factors played a key role in models' accuracy and further research is needed to integrate these in a new generation of more accurate and flexible analytical models.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Data-driven and numerical approaches to predict thermal comfort in traditional courtyards
    Teshnehdel, Saeid
    Mirnezami, Seyedasghar
    Saber, Aniseh
    Pourzangbar, Ali
    Olabi, Abdul Ghani
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 37
  • [2] Data-Driven Smart Avatar for Thermal Comfort Evaluation in Chile
    Hormazabal, Nina
    Franco, Patricia
    Urtubia, David
    Ahmed, Mohamed A.
    BUILDINGS, 2023, 13 (08)
  • [3] Progress in data-driven thermal comfort analysis and modeling
    Culic, Ana
    Nizetic, Sandro
    Gambiroza, Jelena Culic
    Solic, Petar
    ENERGY AND BUILDINGS, 2025, 336
  • [4] DATA-DRIVEN THERMAL COMFORT PREDICTION WITH SUPPORT VECTOR MACHINE
    Peng, Bo
    Hsieh, Sheng-Jen
    PROCEEDINGS OF THE ASME 12TH INTERNATIONAL MANUFACTURING SCIENCE AND ENGINEERING CONFERENCE - 2017, VOL 3, 2017,
  • [5] Development of a health data-driven model for a thermal comfort study
    Jiang, Yi
    Wang, Zhe
    Lin, Borong
    Mumovic, Dejan
    BUILDING AND ENVIRONMENT, 2020, 177
  • [6] Comprehensive analysis of the relationship between thermal comfort and building control research - A data-driven literature review
    Park, June Young
    Nagy, Zoltan
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 : 2664 - 2679
  • [7] BIM and Data-Driven Predictive Analysis of Optimum Thermal Comfort for Indoor Environment
    Gan, Vincent J. L.
    Luo, Han
    Tan, Yi
    Deng, Min
    Kwok, H. L.
    SENSORS, 2021, 21 (13)
  • [8] A data-driven framework for thermal comfort assessment method based on user interaction
    Fan, Qifeng
    Xu, Xiangguo
    Liu, Pu
    Zhang, Hao
    Tang, Shanxuan
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [9] A Performance and Data-Driven Method for Optimization of Traditional Courtyards
    Xu, Zhixin
    Huang, Xia
    Zheng, Xin
    Deng, Ji-Yu
    Sun, Bo
    SUSTAINABILITY, 2024, 16 (13)
  • [10] Data-driven simple thermal models: The importance of the parameter estimates
    Dimitriou, Vanda
    Firth, Steven K.
    Hassan, Tarek M.
    Kane, Tom
    Coleman, Michael
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2614 - 2619