Mechanical performance evaluation of steel fiber-reinforced concrete (FRC) based on multi-mechanical indicators from split hopkinson pressure bar (SHPB) test

被引:18
作者
Li, Qingyan [2 ,3 ]
Shi, Zhenming [1 ]
Zhao, Fei [1 ]
Yu, Songbo [1 ]
Xie, Kelu [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Geotech Engn, Shanghai 200092, Peoples R China
[2] China Geol Survey, Chinese Acad Geol Sci, Key Lab Karst Dynam, Inst Karst Geol,MNR GZAR Innovat Ctr Karst Collaps, Guilin 541004, Peoples R China
[3] UNESCO, Int Res Ctr Karst Ausp, Guilin 541004, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2023年 / 79卷
关键词
Fiber-reinforced concrete; Split Hopkinson pressure bar test; Fracture behavior; Performance evaluation; BEHAVIOR; MICROSTRUCTURE; RESISTANCE; IMPACT;
D O I
10.1016/j.jobe.2023.107898
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fiber-reinforced concrete (FRC) is a new composite material composed of various fibers and a cement matrix that has been widely used and developed in the construction engineering field. In this paper, split Hopkinson pressure bar (SHPB) tests are carried out with the aim of investigating the mechanical properties and failure characteristics of FRC containing different types and dosages of steel fibers. The main findings are as follows: At a fiber content of 0 %-3.5 %, the strength of FRC shows two trends: continuously increasing and then decreasing. The ductility of hookedend steel fiber-reinforced concrete (HFRC) is better than that of hybrid steel fiber-reinforced concrete (HSFRC) and straight steel fiber-reinforced concrete (SFRC) under static loads, whereas the ductility of HSFRC is better than that of SFRC and HFRC under dynamic loads. Straight steel fibers (SF) are better than hooked-end steel fibers (HF) in improving tensile toughness but worse than HF in improving compressive toughness. In terms of the degree of failure, NFRC and HFRC were the most severely fragmented, whereas SFRC and HSFRC exhibited better integrity. Finally, based on the multi-mechanical indicators of the FRC, a comprehensive performance evaluation method and optimization suggestions for the FRC are proposed. This provides theoretical support for the application of FRC as seismic-resistant materials in reinforced structures (i.e., anti-slide piles, retaining walls, and beam structures) of rocky landslides in strong seismic areas, which have important engineering significance.
引用
收藏
页数:17
相关论文
共 46 条
  • [1] Ahmed A, 2022, Case Stud. Constr. Mater., V17
  • [2] Ultra-high-performance concrete: Constituents, mechanical properties, applications and current challenges
    Akhnoukh, Amin K.
    Buckhalter, Chelsea
    [J]. CASE STUDIES IN CONSTRUCTION MATERIALS, 2021, 15
  • [3] [Anonymous], 2011, JGJ 55-2011
  • [4] Mechanical properties of steel and polymer fiber reinforced concrete
    Babaie, Reza
    Abolfazli, Milad
    Fahimifar, Ahmad
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF MATERIALS, 2019, 28 (01) : 119 - 134
  • [5] C. Code, 2013, Fib Model Code for Concrete Structures 2010
  • [6] Mechanical properties and microstructures of Steel-basalt hybrid fibers reinforced Cement-based composites exposed to high temperatures
    Cao, Kai
    Liu, Ganggui
    Li, Hui
    Huang, Zhiyi
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2022, 341
  • [7] CECS, 2019, CECS 13-2009
  • [8] Effects of nanoparticles on the tensile behavior of ultra-high-performance fiber-reinforced concrete at high strain rates
    Dang, Van Phi
    Kim, Dong Joo
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 63
  • [9] Penetration resistance of hybrid-fiber-reinforced high-strength concrete under projectile multi-impact
    Feng, Jun
    Gao, Xudong
    Li, Jizheng
    Dong, Haolin
    He, Qiang
    Liang, Jianguo
    Sun, Weiwei
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2019, 202 : 341 - 352
  • [10] GB/T, 2019, GB/T 50081-2019