Test-Retest Variability and Discriminatory Power of Measurements From Microperimetry and Dark Adaptation Assessment in People With Intermediate Age-Related Macular Degeneration - A MACUSTAR Study Report

被引:7
|
作者
Higgins, Bethany E. [1 ]
Montesano, Giovanni [1 ,2 ]
Dunbar, Hannah M. P. [3 ]
Binns, Alison M. [1 ]
Taylor, Deanna J. [1 ]
Behning, Charlotte [4 ]
Abdirahman, Amina [3 ]
Schmid, Matthias C. [4 ]
Terheyden, Jan H. [5 ]
Zakaria, Nadia [6 ]
Poor, Stephen [7 ]
Finger, Robert P. [5 ]
Leal, Sergio [8 ]
Holz, Frank G. [5 ]
Rubin, Gary S. [3 ]
Luhmann, Ulrich F. O. [9 ]
Crabb, David P. [10 ]
机构
[1] City Univ London, London, England
[2] Moorfields Eye Hosp NHS Fdn Trust, London, England
[3] UCL Inst Ophthalmol, London, England
[4] Univ Bonn, Inst Med Biometry Informat & Epidemiol, Med Fac, Bonn, Germany
[5] Univ Hosp Bonn, Dept Ophthalmol, Bonn, Germany
[6] Novartis Inst Biomed Res, Dept Translat Med, Cambridge, MA USA
[7] Novartis Inst Biomed Res, Dept Ophthalmol Res, Cambridge, MA USA
[8] Bayer AG, Berlin, Germany
[9] Roche Innovat Ctr Basel, Roche Pharmaceut Res & Early Dev, Translat Med Ophthalmol, Basel, Switzerland
[10] City Univ London, Optometry & Vis Sci, Northampton Sq, London EC1V 0HB, England
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2023年 / 12卷 / 07期
关键词
test-retest; repeatability; macular integrity assessment (S-MAIA); AdaptDx; age-related macular degeneration (AMD); INTEGRITY ASSESSMENT; RELIABILITY; SENSITIVITY; PROGRESSION; PERIMETRY;
D O I
10.1167/tvst.12.7.19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study was to assess test-retest variability and discriminatory power of measures from macular integrity assessment (S-MAIA) and AdaptDx.Methods: This is a cross-sectional study of 167 people with intermediate age-related macular degeneration (iAMD), no AMD (controls; n = 54), early AMD (n = 28), and late AMD (n = 41), recruited across 18 European ophthalmology centers. Repeat measures of mesopic and scotopic S-MAIA average (mean) threshold (MMAT decibels [dB] and SMAT [dB]) and rod intercept time (RIT [mins]) at 2 visits 14 (+/- 7) days apart were recorded. Repeat measures were assessed by Bland-Altman analysis, intra-class correlation coefficients (ICCs) and variability ratios. Secondary analysis assessed the area under the receiver operating characteristic curves (AUC) to determine the ability to distinguish people as having no AMD, early AMD, or iAMD.Results: Data were available for 128, 131, and 103 iAMD participants for the mesopic and scotopic S-MAIA and AdaptDx, respectively. MMAT and SMAT demonstrate similar test retest variability in iAMD (95% confidence interval [CI] ICC of 0.79-0.89 and 0.78-0.89, respectively). ICCs were worse in RIT (95% CI ICC = 0.55-0.77). All tests had equivalent AUCs (approximately 70%) distinguishing between subjects with iAMD and controls, whereas early AMD was indistinguishable from iAMD on all measures (AUC = <55%). A learning effect was not seen in these assessments under the operating procedures used. Conclusions: MMAT, SMAT, and RIT have adequate test-retest variability and are all moderately good at separating people with iAMD from controls.
引用
收藏
页数:14
相关论文
共 15 条
  • [11] Assessment of the Classification of Age-Related Macular Degeneration Severity from the Northern Ireland Sensory Ageing Study Using a Measure of Dark Adaptation
    Higgins, Bethany E.
    Montesano, Giovanni
    Crabb, David P.
    Naskas, Timos T.
    Graham, Katie W.
    Chakravarthy, Usha
    Kee, Frank
    Wright, David M.
    Hogg, Ruth E.
    OPHTHALMOLOGY SCIENCE, 2022, 2 (04):
  • [12] Assessment of Retinotopic Rod Photoreceptor Function Using a Dark-Adapted Chromatic Perimeter in Intermediate Age-Related Macular Degeneration
    Fraser, Rogan G.
    Tan, Rose
    Ayton, Lauren N.
    Caruso, Emily
    Guymer, Robyn H.
    Luu, Chi D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (13) : 5436 - 5442
  • [13] Features of intermediate and late dry age-related macular degeneration on adaptive optics ophthalmoscopy: Pinnacle Study Report 8
    Hagag, Ahmed M.
    Holmes, Christopher
    Raza, Ahmer
    Riedl, Sophie
    Anders, Philipp
    Kaye, Rebecca
    Prevost, Toby
    Fritsche, Lars G.
    Rueckert, Daniel
    Bogunovic, Hrvoje
    Scholl, Hendrick P. N.
    Schmidt-Erfurth, Ursula
    Lotery, Andrew J.
    Sivaprasad, Sobha
    EYE, 2025,
  • [14] Baseline data from a multicenter, 5-year, prospective cohort study of Japanese age-related macular degeneration: an AMD2000 report
    Tsujikawa, Akitaka
    Akagi-Kurashige, Yumiko
    Yuzawa, Mitsuko
    Ishibashi, Tatsuro
    Nakanishi, Hideo
    Nakatani, Eiji
    Teramukai, Satoshi
    Fukushima, Masanori
    Yoshimura, Nagahisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2018, 62 (02) : 127 - 136
  • [15] Baseline data from a multicenter, 5-year, prospective cohort study of Japanese age-related macular degeneration: an AMD2000 report
    Akitaka Tsujikawa
    Yumiko Akagi-Kurashige
    Mitsuko Yuzawa
    Tatsuro Ishibashi
    Hideo Nakanishi
    Eiji Nakatani
    Satoshi Teramukai
    Masanori Fukushima
    Nagahisa Yoshimura
    Japanese Journal of Ophthalmology, 2018, 62 : 127 - 136