Comparing the Effectiveness and Safety of MedAn with the Nishikawa Blade and UE Videolaryngoscopes for Left-Sided Double-Lumen Endobronchial Tube Intubation: A Randomized Controlled Trial

被引:1
|
作者
Zhang, Yong [1 ]
Zhang, Wenwen [1 ]
Wang, Shuai [1 ]
Yin, Hailing [1 ]
Xu, Yajie [1 ]
Fang, Zhaojing [1 ]
Bao, Hongguang [1 ]
Zhang, Chen [1 ]
Wang, Xiaoliang [1 ]
Liu, Wentao [2 ]
机构
[1] Nanjing Med Univ, Nanjing Hosp 1, Dept Anesthesiol Perioperat & Pain Med, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Sch Basic Med Sci, Dept Pharmacol, Nanjing, Jiangsu, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2023年 / 29卷
关键词
Laryngoscopes; Intubation; Anesthesia; Endotracheal; TRACHEAL INTUBATION; ENDOTRACHEAL-TUBE; DIFFICULT AIRWAY; LARYNGOSCOPY; MACINTOSH; PLACEMENT;
D O I
10.12659/MSM.940916
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: The purpose of this study was to compare the effectiveness and safety of the MedAn videolaryngoscope with the Nishikawa blade (MedAn) vs the UE videolaryngoscope (UE) for intubation with a left-sided double-lumen endobronchial tube (LDLT) in patients with normal airways.Material/Methods: We randomly categorized 106 patients scheduled to undergo elective thoracic surgery with LDLT for one-lung ventilation into 2 groups: the UE group (Group UE) and the MedAn group (Group MedAn), using the MedAn or UE for LDLT intubation. The primary outcome was time to successful intubation. The Cormack-Lehane classi-fication of laryngeal view was the key secondary outcome. Other secondary outcomes included first-attempt and overall intubation success rates, laryngoscopy time, LDLT placement time, operators' subjective evaluation of videolaryngoscopes, hemodynamic changes during videolaryngoscopic intubation, and adverse outcomes.Results: The time to successful intubation and LDLT placement time of Group MedAn were 42.0 (32.35, 47.0) s and 23.0 (18.0, 26.0) s, and it was shorter than in Group UE (median, 42 s vs 49 s, 23 s vs 30 s, P<0.001). Group MedAn had a better laryngeal view (P=0.03) and less subglottic/tracheal mucosal injury (P<0.001) than Group UE. Moreover, the operators' subjective grading of ease of laryngoscopy, quality of view, and ease of LDLT place -ment were higher in Group MedAn than in Group UE (P<0.05).Conclusions: Compared with the UE, the MedAn could reduce the intubation time and provide a better laryngeal view and sufficient intubation space for safer LDLT intubation in patients with normal airways.
引用
收藏
页数:9
相关论文
共 32 条
  • [1] A modified technique to improve the outcome of intubation with a left-sided double-lumen endobronchial tube
    Hsu, Hung-Te
    Chou, Shah-Hwa
    Chou, Chun-Yen
    Tseng, Kuang-Yi
    Kuo, Yi-Wei
    Chen, Mei-Chun
    Cheng, Kuang-I
    BMC ANESTHESIOLOGY, 2014, 14
  • [2] Comparison of conventional and fibreoptic-guided advance of left-sided double-lumen tube during endobronchial intubation A randomised controlled trial
    Park, Jin-Woo
    Jo, Ji H.
    Park, Jin H.
    Bae, Yu K.
    Park, Seong-Joo
    Cho, Sung-Woo
    Han, Sung-Hee
    Kim, Jin-Hee
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (06) : 466 - 473
  • [3] A Randomized Controlled Trial Comparing the Utility of Lighted Stylet and GlideScope for Double-Lumen Endobronchial Intubation
    Chang, Jee-Eun
    Kim, Hyerim
    Mm, Seong-Won
    Lee, Jung-Man
    Ryu, Jung-Hee
    Yoon, Soohyuk
    Hwang, Jin-Young
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) : 290 - 296
  • [4] Intubation with VivaSight or conventional left-sided double-lumen tubes: a randomized trial
    Schuepbach, Rolf
    Grande, Bastian
    Camen, Giovanni
    Schmidt, Alexander R.
    Fischer, Henrik
    Sessler, Daniel I.
    Seifert, Burkhardt
    Spahn, Donat R.
    Ruetzler, Kurt
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (07): : 762 - 769
  • [5] A Comparison of 3 Videolaryngoscopes for Double-Lumen Tube Intubation in Humans by Users With Mixed Experience: A Randomized Controlled Study
    El-Tahan, Mohamed R.
    Khidr, Alaa M.
    Gaarour, Ihab S.
    Alshadwi, Saeed A.
    Alghamdi, Talal M.
    Al'ghamdi, Abdulmohsen
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (01) : 277 - 286
  • [6] A randomised controlled trial comparing the GlideScope® and the Macintosh laryngoscope for double-lumen endobronchial intubation
    Russell, T.
    Slinger, P.
    Roscoe, A.
    McRae, K.
    Van Rensburg, A.
    ANAESTHESIA, 2013, 68 (12) : 1253 - 1258
  • [7] Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial
    Seo, Jeong-Hwa
    Yoon, Susie
    Min, Se-Hee
    Row, Hyung Sang
    Bahk, Jae-Hyon
    PLOS ONE, 2019, 14 (01):
  • [8] Efficacy and safety of video double-lumen tube intubation in lateral position in patients undergoing thoracic surgery: a randomized controlled trial
    Rao, Qianqian
    Yu, Hong
    Li, Ping
    Zhang, Gongwei
    Zeng, Jun
    Pu, Qiang
    Yu, Hai
    BMC ANESTHESIOLOGY, 2024, 24 (01):
  • [9] A Randomized Controlled Trial Comparing Novel Triple-Cuffed Double-Lumen Endobronchial Tubes with Conventional Double-Lumen Endobronchial Tubes for Lung Isolation
    Kim, Namo
    Byon, Hyo-Jin
    Kim, Go Eun
    Park, Chungon
    Joe, Young Eun
    Suh, Sung Min
    Oh, Young Jun
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (04)
  • [10] Time to tracheal intubation over a fibreoptic bronchoscope using a silicone left double-lumen endobronchial tube versus polyvinyl chloride single-lumen tube with bronchial blocker: a randomized controlled non-inferiority trial
    Yoo, Ji Young
    Chae, Yun Jeong
    Park, Sung Yong
    Haam, Seokjin
    Kim, Myungseob
    Kim, Dae Hee
    JOURNAL OF THORACIC DISEASE, 2019, 11 (03) : 901 - 908